Standard PTA balloons
Pacific™ Plus PTA catheter
Standard PTA balloons
Pacific™ Plus PTA catheter
The Pacific™ Plus PTA catheter features a broad size matrix and a low profile to handle cases above the knee (ATK) or below the knee (BTK).
Description
The Pacific™ Plus PTA catheter is intended to dilate stenoses in the iliac, femoral, iliofemoral, popliteal, infrapopliteal, and renal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. Catheters with balloon diameters of 4–7 mm (in all lengths) are also indicated for stent postdilatation in the peripheral arteries.
The Pacific™ Plus PTA catheter is the 0.018" go-to balloon for everyday use. It's shaft design provides the trackability, flexibility, and kink resistance needed to reach your destination.
The Pacific Plus’ shaft design provides the trackability, flexibility, and kink resistance needed to reach your destination.
Features
Versatility advantage
- Multiple catheter lengths, including 200 cm, give you the option to treat via femoral or radial† access
- Short and long balloons, small and large diameters
- Short and long shafts
- Provides versatility to treat both ATK and BTK lesions
- Wrap technology enables multiple inflations
Portfolio refresh for improved performance
A redesign of the 4–7 mm balloons in 2023 included:
- Improving the catheter design to optimize introducer sheath compatibility without compromising inflation time‡
- Enhancing inner and outer shaft diameter for better pushability and faster deflation times

Dual middle marker bands provide enhanced visibility for precise placement of 200-300 mm balloons (4-7mm).†
Specifications
Type | Specification |
---|---|
Catheter design | Over the wire (OTW), coaxial shaft |
Balloon material | Proprietary |
Balloon coating | Hydrophilic |
Balloon marker | 2 or 4 swaged, platinum-iridium |
Usable shaft lengths | 90, 130, 150, 180, and 200 cm |
Shaft diameter | 4.0 and 5.0 F |
Maximum guidewire compatibility | 0.018" |
Ordering information
Resources
Related links
Similar products
-
Admiral Xtreme™ PTA balloon catheter
The Admiral Xtreme™ PTA balloon catheter is available in 250 and 300 mm balloon lengths.
-
Chocolate™* PTA balloon catheter
The Chocolate™* PTA balloon is the only nitinol-caged balloon with controlled dilatation, designed for 1:1 vessel sizing.
-
EverCross™ PTA catheter
The EverCross™ PTA catheter is used to treat peripheral arterial disease (PAD) in many vessel sizes and lesion types.
-
Fortrex™ HP PTA balloon catheter
The Fortrex™ HP PTA balloon catheter balances push and track to deliver high pressure, targeted treatment to challenging AV access lesions.
-
NanoCross™ Elite PTA catheter
The NanoCross™ Elite PTA Catheter's robust shaft design makes it easier to access, reach and treat distal lesions in the lower leg.
-
RapidCross™ RX PTA catheter
The RapidCross™ rapid exchange (RX) percutaneous transluminal angioplasty (PTA) catheter is used in treating distal lesions in the small vessels below the knee.
† Complications associated with radial access may include, but are not limited to abrupt vessel closure, vessel spasm, perforation or rupture of the artery, dissection, pseudoaneurysm, hematoma and thrombosis.
‡ Bench test data on file at Medtronic. Bench tests may not be indicative of clinical performance.