Item number | Balloon diameter (mm) |
Balloon length (mm) |
Catheter length (cm) |
Guidewire (in) | Introducer sheath (Fr) |
Nominal pressure (atm) |
Rated burst pressure (atm) |
---|---|---|---|---|---|---|---|
CB1415025040 OTW | 2.5 | 40 | 150 | 0.014 | 5 | 9 | 14 |
CB1415025080 OTW | 2.5 | 80 | 150 | 0.014 | 5 | 9 | 14 |
CB1415025120 OTW | 2.5 | 120 | 150 | 0.014 | 5 | 9 | 14 |
CB1415030040 OTW | 3.0 | 40 | 150 | 0.014 | 5 | 9 | 14 |
CB1415030080 OTW | 3.0 | 80 | 150 | 0.014 | 5 | 9 | 14 |
CB1415030120 OTW | 3.0 | 120 | 150 | 0.014 | 5 | 9 | 14 |
CB1413535040 OTW | 3.5 | 40 | 135 | 0.014 | 5 | 9 | 14 |
CB1413535080 OTW | 3.5 | 80 | 135 | 0.014 | 5 | 9 | 14 |
CB1413535120 OTW | 3.5 | 120 | 135 | 0.014 | 5 | 9 | 14 |
CB1413540040 OTW | 4.0 | 40 | 135 | 0.014 | 5 | 9 | 14 |
CB1413540080 OTW | 4.0 | 80 | 135 | 0.014 | 5 | 9 | 14 |
CB1413540120 OTW | 4.0 | 120 | 135 | 0.014 | 5 | 9 | 14 |
CB1812050040 OTW | 5.0 | 40 | 120 | 0.018 | 6 | 6 | 12 |
CB1812050080 OTW | 5.0 | 80 | 120 | 0.018 | 6 | 6 | 12 |
CB1812050120 OTW | 5.0 | 120 | 120 | 0.018 | 6 | 6 | 12 |
CB1812060040 OTW | 6.0 | 40 | 120 | 0.018 | 6 | 6 | 12 |
CB1812060080 OTW | 6.0 | 80 | 120 | 0.018 | 6 | 6 | 12 |
CB1812060120 OTW | 6.0 | 120 | 120 | 0.018 | 6 | 6 | 12 |
Specialty PTA balloons
Chocolate™* PTA balloon catheter
<p>The Chocolate™* PTA balloon is the only nitinol-caged balloon with controlled dilatation, designed for 1:1 vessel sizing.</p>
Product details
During inflation, the cage causes the balloon to dilatate in a controlled manner, alleviating dog-boning and overinflation. The cage also causes the balloon to form a series of segmented pillows and grooves along the entire lesion. The pillows apply force to create small dissections that are necessary for effective dilatation. The grooves relieve the stress and stop dissections from propagating.
Product design
- Inflation: During inflation, the cage causes the balloon to form a series of segmented pillows and grooves along the entire lesion.
- Balloon: The balloon is confined to the cage during inflation, preventing dog-boning, and protecting healthy tissue.
- Cage: The nitinol cage expands with balloon, protecting the vessel from torsional stresses and minimizing dissections.1
- Pillows: The pillows apply force to create small dissections that are necessary for effective dilatation.
- Grooves: The grooves relieve the stress and stop dissections from propagating.
Drs. Laiq Raja and Mehdi Shishehbor discuss their use of the Chocolate™* PTA balloon, including in BTK cases.
Laiq Raja, M.D., FACC, FSCAI, Interventional Cardiologist, El Paso Cardiology Associates, PA
Mehdi H. Shishehbor, D.O., Ph.D., M.P.H., Director, Interventional Cardiovascular Center, Harrington Heart and Vascular Institute, University Hospitals, Cleveland, OH
Chocolate™* PTA balloon with controlled dilatation
Watch this short video to learn about percutaneous old balloon angioplasty (POBA) limitations and Chocolate™* solutions when treating peripheral artery disease (PAD), opening your below-the-knee (BTK) options.
Ordering information
Similar products
-
Admiral Xtreme™ PTA balloon catheter
The Admiral Xtreme™ PTA balloon catheter is available in 250 and 300 mm balloon lengths.
-
EverCross™ PTA catheter
The EverCross™ PTA catheter is used to treat peripheral arterial disease (PAD) in many vessel sizes and lesion types.
-
Fortrex™ HP PTA balloon catheter
The Fortrex™ HP PTA balloon catheter balances push and track to deliver high pressure, targeted treatment to challenging AV access lesions.
-
NanoCross™ Elite PTA catheter
The NanoCross™ Elite PTA Catheter's robust shaft design makes it easier to access, reach and treat distal lesions in the lower leg.
-
Pacific™ Plus PTA catheter
The Pacific™ Plus PTA catheter features a broad size matrix and a low profile to handle cases above the knee (ATK) or below the knee (BTK).
-
RapidCross™ RX PTA catheter
The RapidCross™ rapid exchange (RX) percutaneous transluminal angioplasty (PTA) catheter is used in treating distal lesions in the small vessels below the knee.
TM* Third party brands are trademarks of their respective owners.
- Medtronic data on file, Final Study Report The Chocolate BAR CLR782.