Specialty PTA balloons

Chocolate™* PTA balloon catheter

<p>The Chocolate™* PTA balloon is the only nitinol-caged balloon with controlled dilatation, designed for 1:1 vessel sizing.</p>


Product details

During inflation, the cage causes the balloon to dilatate in a controlled manner, alleviating dog-boning and overinflation. The cage also causes the balloon to form a series of segmented pillows and grooves along the entire lesion. The pillows apply force to create small dissections that are necessary for effective dilatation. The grooves relieve the stress and stop dissections from propagating.  


This is a close-up of the Chocolate™* PTA balloon.

Product design

This is an illustration of the Chocolate™* PTA balloon inside the vessel with numbered callouts.

  1. Inflation: During inflation, the cage causes the balloon to form a series of segmented pillows and grooves along the entire lesion.
  2. Balloon: The balloon is confined to the cage during inflation, preventing dog-boning, and protecting healthy tissue.
  3. Cage: The nitinol cage expands with balloon, protecting the vessel from torsional stresses and minimizing dissections.1
  4. Pillows: The pillows apply force to create small dissections that are necessary for effective dilatation. 
  5. Grooves: The grooves relieve the stress and stop dissections from propagating.

Drs. Laiq Raja and Mehdi Shishehbor discuss their use of the Chocolate™* PTA balloon, including in BTK cases.

Laiq Raja, MD, FACC, FSCAI, Interventional Cardiologist, El Paso Cardiology Associates, PA


Mehdi H. Shishehbor, DO, PhD, MPH, Director, Interventional Cardiovascular Center, Harrington Heart and Vascular Institute, University Hospitals, Cleveland, OH


Chocolate™* PTA balloon with controlled dilatation

Watch this short video to learn about percutaneous old balloon angioplasty (POBA) limitations and Chocolate™* PTA balloon solutions when treating peripheral artery disease (PAD), opening your below-the-knee (BTK) options.


Ordering information

Item number Balloon
diameter (mm)
Balloon
length (mm)
Catheter
length (cm)
Guidewire (in) Introducer
sheath (Fr)
Nominal
pressure (atm)
Rated burst
pressure (atm)
CB1415025040OTW 2.5 40 150 0.014 5 9 14
CB1415025080OTW 2.5 80 150 0.014 5 9 14
CB1415025120OTW 2.5 120 150 0.014 5 9 14
CB1415030040OTW 3.0 40 150 0.014 5 9 14
CB1415030080OTW 3.0 80 150 0.014 5 9 14
CB1415030120OTW 3.0 120 150 0.014 5 9 14
CB1413535040OTW 3.5 40 135 0.014 5 9 14
CB1413535080OTW 3.5 80 135 0.014 5 9 14
CB1413535120OTW 3.5 120 135 0.014 5 9 14
CB1413540040OTW 4.0 40 135 0.014 5 9 14
CB1413540080OTW 4.0 80 135 0.014 5 9 14
CB1413540120OTW 4.0 120 135 0.014 5 9 14
CB1812050040OTW 5.0 40 120 0.018 6 6 12
CB1812050080OTW 5.0 80 120 0.018 6 6 12
CB1812050120OTW 5.0 120 120 0.018 6 6 12
CB1812060040OTW 6.0 40 120 0.018 6 6 12
CB1812060080OTW 6.0 80 120 0.018 6 6 12
CB1812060120OTW 6.0 120 120 0.018 6 6 12


 

™* Third-party brands are trademarks of their respective owners.

  1. Medtronic data on file (CLR782), Final study report: The Chocolate BAR. Accepted February 8, 2018.