Cryoablation steerable sheaths
FlexCath Contour™ steerable sheath
Cryoablation steerable sheaths
FlexCath Contour™ steerable sheath
The FlexCath Contour™ steerable sheath provides enhanced maneuverability during atrial fibrillation ablation procedures.
Description
FlexCath Contour™ steerable sheaths enable electrophysiologists to steer therapy with confidence. Enhanced maneuverability, refined transitions, and the zero exchange workflow are experienced throughout each ablation procedure.
Features
Enhanced maneuverability
The FlexCath Contour™ steerable sheath is designed to maintain shape and performance throughout the procedure, with increased, bi-directional deflection and a redesigned shaft. Two tip lengths enable options for greater access to the right inferior pulmonary vein (RIPV).1,2
- 13 mm tip
- 20 mm tip


Refined transitions
The distal tip of the sheath has been redesigned with a more gradual approach angle and flexible material to enable a smooth sheath-dilator transition into patient vasculature and across the septum.3,4

FlexCath Advance™ steerable sheath distal tip

FlexCath Contour™ steerable sheath distal tip
Zero exchange workflow5,6
The FlexCath Contour™ sheath is designed for transseptal needle introduction and is compatible with the FlexCath Cross™ transseptal solution, eliminating the need to exchange between sheaths, guidewires, or needles.

FlexCath Cross™ transseptal solution needle

FlexCath Contour™ steerable sheath handle and homeostasis valve
Available in both 10 Fr and 12 Fr, the FlexCath Contour™ steerable sheath is the only sheath specifically designed and tested for use with the Arctic Front™ family of cardiac cryoablation catheters and the PulseSelect™ pulsed field ablation catheter.

FlexCath Contour™ 10 Fr with the PulseSelect™ pulsed field ablation catheter

FlexCath Contour™ 12 Fr with the Arctic Front Advance Pro™ cryoablation catheter
Product information

- Dilator
- Radiopaque marker
- Sheath tip with two options
- Variable-braided shaft
- Bi-directional sheath deflection
- Ergonomically designed handle
- Hemostasis valve
Ordering information
Resources
Related products
- Based on internal report (10912205DOC), Anatomical Analysis for 12Fr Delivery Sheaths.
- Based on internal report (10911205DOC), Appendices.
- Based on internal report (D00947402), FlexCath Contour 10Fr Design Validation Report.
- Based on internal report (D00947406), FlexCath Contour 12Fr Design Validation Report.
- Based on FlexCath Contour US IFU 12Fr (M987301A001).
- Based on FlexCath Contour 10Fr US IFU (M033684C001).