Item number | Diameter (cm) | Units per box |
---|---|---|
PCO4VP | 4.6 | 1 |
PCO6VP | 6.6 | 1 |
PCO8VP | 8.6 | 1 |
Composite mesh
Parietex™ composite ventral patch
The Parietex™ composite ventral patch is intended for the reinforcement of adbominal wall soft tissue where a weakness exists for primary ventral hernia repair.
Features
Designed for optimal abdominal wall conformability†,8-10
The mesh conforms to the abdominal cavity thanks to the expander, positioning, and fixation system (handles and peripheral fixation).
Provides easy deployment and fixation system‡,8,9
Pulling on the handles will help user to position the mesh in the center of the defect.
The fixation system based on the four semi-peripheral points, provides a balanced fixation on healthy tissue away from the center of the defect.
Supports tissue integration while minimizing visceral attachment with collagen film‡,1-4,11-14
Macroporous textile enables consistent tissue integration.
Resorbable collagen film minimizes visceral attachment.
Frequently asked questions
Yes, the mesh must be hydrated in its original blister before being handled. This is carried out by immersing it completely in sterile saline solution for several seconds to ensure its conformability and flexibility.
The mesh should be used in the form in which it is provided without being cut. This will ensure the integrity of the mesh.
Yes. The suturing technique used to anchor the mesh is left up to the practitioner.
Specifications
Deployment system | Rigid and absorbable PGLA expanders combined with removable handles for easy deployment |
---|---|
Fixation | Semi-peripheral fixation on the four cardinal points |
Minimizing tissue attachment | Absorbable collagen film |
Size | 4.6 cm / 6.6 cm / 8.6 cm |
Pore size | Green textile: 1.1 mm × 1.6 mm White textile: 1.5 mm × 1.8 mm |
Sterilization method | Ethylene oxide (EtO) |
Shelf life | 5 years |
Ordering information
Similar products
-
Parietene™ DS composite meshParietene™ DS composite mesh is intended for the reinforcement of abdominal wall soft tissue where a weakness exists.
-
Parietene™ macroporous meshParietene™ macroporous mesh is intended for reinforcement of abdominal wall soft tissue where a weakness exists, involving abdominal wall hernia repairs.
-
Parietex™ composite mesh
Parietex™ composite mesh is used for the reinforcement of tissues during surgical repairs including hiatal hernias.
-
Parietex™ composite parastomal mesh (PCOPM)Parietex™ composite parastomal mesh is intended for the reinforcement of abdominal wall soft tissues where a weakness exists during hernia repair.
-
Parietex™ optimized composite mesh
Parietex™ optimized composite mesh is intended for the reinforcement of abdominal wall soft tissues where a weakness exists.
-
Symbotex™ composite mesh
The Symbotex™ composite mesh is intended for the reinforcement of abdominal wall soft tissue where a weakness exists.
Do not use by laparoscopic approach. The device is designed for placement by open surgery only. The mesh should be used in the form in which it is provided without being cut. This will ensure the integrity of the mesh
† Based on preclinical animal and benchtop studies. Animal data and benchop studies are not necessarily indicative of human clinical outcomes
‡ Tissue integration is indirectly assessed in clinical studies by the reported low recurrence rates.
- Burger JW, Halm JA, Wijsmuller AR, ten Raa S, Jeekel J. Evaluation of new prosthetic meshes for ventral hernia repair. Surg Endosc. 2006;20(8):1320–1325.
- Based on internal test report 0506-140983, Evaluation of the local tissue effects and tissue attachment minimization of a Parietex™ composite ventral patch in a rat caecal abrasion model. January 2012.
- Based on internal test report 0506-140983, Evaluation of the local tissue effects and tissue attachment minimization of a Parietex™ composite ventral patch in a rat caecal abrasion model — amendment 1. February 2012.
- Berrevoet F, Doerhoff C, Muysoms F, et al. Open ventral hernia repair with a composite ventral patch - final results of a multicenter prospective study. BMC Surg. 2019;19(1):93.
- Based on internal report, Gillion JF. Club Hernie registry extraction: Parietex™ composite ventral patch (Medtronic). March 2021.
- Berrevoet F, Van den Bossche B, de Baerdemaeker L, de Hemptinne B. Laparoscopic evaluation shows deficiencies in memory ring deployment during small ventral hernia repair. World J Surg. 2010;34(7):1710–1715.
- Berrevoet F, Doerhoff C, Muysoms F, et al. A multicenter prospective study of patients undergoing open ventral hernia repair with intraperitoneal positioning using the monofilament polyester composite ventral patch: interim results of the PANACEA study. Med Devices (Auckl). 2017;10:81–88.
- Based on internal test report 0506CR051a, Design validation report for the Parietex™ composite ventral patch. November 2012.
- Based on internal test report 0506CR066, Marketing assessment design validation PCO ventral patch. March 2012.
- Based on internal test report 0506CR017, Prototype evaluation — pig testing. February 2011.
- Based on internal test report 0506-140983, Evaluation of the local tissue effects and tissue attachment minimization of a Parietex™ composite ventral patch in a rat caecal abrasion model — amendment 2. April 2012.
- Based on internal test report 0506-141814, Performance and local tissue effect evaluation of the Parietex™ composite ventral patch in a pig hernia model for ten days and four weeks. March 2012.
- Based on internal test report 0506-141814, Performance and local tissue effect evaluation of the Parietex™ composite ventral patch in a pig hernia model for ten days and four weeks — amendment 1. June 2012.
- García-Moreno F, Pérez-López P, Sotomayor S, et al. Comparing the host tissue response and peritoneal behavior of composite meshes used for ventral hernia repair. J Surg Res. 2015;193(1):470–482.