Item number | Description | Length (cm) | Units per box |
---|---|---|---|
LF1930T | LigaSure™ Maryland jaw thoracic sealer-divider with nano-coating | 30 | 6 |
Laparoscopic instruments
LigaSure™ Maryland jaw thoracic sealer-divider with nano-coating
<p>The LigaSure™ Maryland jaw thoracic sealer-divider is a multifunctional nano-coated instrument designed for sealing pulmonary veins and arteries.</p>
Features
Transform your thoracic procedures with the LigaSure™ Maryland jaw thoracic device
The multifunctional LigaSure™ Maryland jaw thoracic device complements thoracic procedures by providing:
One-step vessel sealing7
Enhanced blunt dissection†,8,9
Secure, atraumatic grasping†,8,9
Cold cutting independent of sealing7,8
The LigaSure™ technology difference
Reliable LigaSure™ vessel-sealing technology drives the LigaSure™ thoracic device. It works by using the body’s own collagen and elastin to create a permanent seal that is designed to withstand three times normal pulmonary systolic blood pressure.‡,10
Plus, LigaSure™ technology eliminates the guesswork — and minimizes thermal spread§,11 — by automatically discontinuing energy delivery when the seal cycle is complete.11
Please contact your local sales representative for additional information.
Specifications
Physical characteristics | |
---|---|
General | Sterile, single use |
Shaft length (cm) | 23 |
Shaft rotation | 350 degrees |
Jaw design | Curved |
Seal plate length (mm) | 20.3 |
Cut length (mm) | 18.5 |
Foot switching | yes |
Generator compatibility | Valleylab™ FT10 energy platform |
Ordering information
Resources
Related links
Related products
Similar products
-
LigaSure™ XP Maryland jaw sealer-divider with nano-coating
The LigaSure™ XP Maryland jaw device offers next-level vessel sealing technology − including latching handles and one-step sealing.
-
LigaSure™ retractable L-hook laparoscopic sealer-divider
The LigaSure™ retractable L-hook laparoscopic sealer-divider combines the functionality of five laparoscopic devices into one versatile instrument.
™* Third-party brands are trademarks of their respective owners.
† 31 of 33 surgeons surveyed after use agreed. Compared to straight jaws.
‡ Bench testing model used to evaluate burst pressure of renal arteries. May not be indicative of clinical performance. Evidence: Testing performed on fresh porcine kidneys, using LigaSure devices % probability of a burst > 360 mmHg: LF1212A (99.2%); LF1637 (96.8%); LF4318 (98.2%); and LS1037 (98.2%).
§ Based on systemic vasculature. Compared to Olympus Thunderbeat™*.
- Based on internal report RE00138840, Device length recommendation, thoracic (LF1930T). February 6, 2018.
- Based on internal test report RE00125866, Jaw range burst pressure evaluation of EB4 thoracic Maryland device (LF1930T); conducted on tissue. November 20–21, 2017 and November 27–30, 2017.
- Based on internal test report RE00134865, Burst pressure verification of pulmonary veins (LF1930T). January 17–18, 2018.
- Based on internal test report RE00122515, Verification of the LigaSure™ LF1930T device in a GLP chronic hemostasis canine study on pulmonary vasculature. January 8–10, 2018.
- Based on internal test report RE00128442, GLP acute pulmonary vasculature hemostasis verification study of the LF1930T in hounds. December 8, 2017.
- Based on internal report RE00147462, Pulmonary sealing claims for the LigaSure™ device (LF1930T). March 29, 2018.
- LigaSure™ Maryland jaw thoracic sealer/divider one-step sealing, nano-coated instructions for use. Medtronic, Boulder, CO; 2018.
- Based on internal test report RE00140529, rev A, LigaSure™ Maryland device, nano-coated (LF19XX) tissue testing (memo). March 5, 2018.
- Based on internal test report R0035742, Maryland validation, Houston and Los Angeles: independent surgeon feedback collected during porcine labs. April 16–18 and April 30–May 3, 2013.
- Based on Covidien ex-vivo Renal Burst Pressure report: Verification - Report - LigaSure™ Renal Bench Burst Pressure Evaluation of the Valleylab™ FT10. May 3, 2015; R0064457
- Based on internal test report RE00025819, rev A, LigaSure™ device data sources for VLFT10 white papers. September 2015.