Support catheters

Navien™ intracranial support catheter

<p>The Navien™ intracranial support catheter&nbsp;is a single lumen, flexible, variable stiffness composite catheter. The catheter shaft has a hydrophilic coating to reduce friction during use.</p>

Features

Navien™ features breakdown

 

  1. Flat wire nitinol coil enables maintenance of lumen inner diameter
  2. Polyester jacket provides proximal stability and distal flexibility
  3. Polymer adhesive binding agent for layers
  4. Platinum coil marker provides radiopacity of tip
  5. PTFE liner enables smooth delivery of micro catheters and interventional devices

The Navien™ advantage2–4

The large inner diameter (5 Fr: 0.058"–6 Fr: 0.072") is providing more clinical treatment options:

  • Higher flow rate enables better contrast injections and visualization
  • More flexibility allows the use of different device combinations
  • Specific braiding facilitates durability and low ovalization rates
  • Large inner diameter among 5/6 Fr catheters

Characteristics

  • Provides the micro catheter with a distal base of support
  • Micro catheter stability
  • Infusion of contrast in large volume

Ordering information

Navien™ 58 5 Fr catheters1

Item number Maximum outer diameter (Fr / in) Inner diameter (in) Length (cm) Tip shape Max wire compatibility (in) Flexible distal length (cm)
RFX058-105-08 5 / 0.070 0.058 105 Straight 0.038 8
RFX058-115-08 5 / 0.070 0.058 115 Straight 0.038 8
RFX058-125-08 5 / 0.070 0.058 125 Straight 0.038 8
RFX058-130-08 5 / 0.070 0.058 130 Straight 0.038 8

Navien™ 72 6 Fr catheters1

Item number Maximum outer diameter (Fr / in) Inner diameter (in) Length (cm) Tip shape Max wire compatibility (in) Flexible distal length (cm)
RFX072-95-08 6 / 0.084 0.072 95 Straight 0.038 8
RFX072-95-08MP 6 / 0.084 0.072 95 Multi-purpose 25° 0.038 8
RFX072-105-08 6 / 0.084 0.072 105 Straight 0.038 8
RFX072-105-08MP 6 / 0.084 0.072 105 Multi-purpose 25° 0.038 8
RFX072-115-08 6 / 0.084 0.072 115 Straight 0.038 8
RFX072-115-08MP 6 / 0.084 0.072 115 Multi-purpose 25° 0.038 8
RFX072-125-08 6 / 0.084 0.072 125 Straight 0.038 8
RFX072-125-08MP 6 / 0.084 0.072 125 Multi-purpose 25° 0.038 8
RFX072-130-08 6 / 0.084 0.072 130 Straight 0.038 8
RFX072-130-08MP 6 / 0.084 0.072 130 Multi-purpose 25° 0.038 8

† Data derived from reference bench testing may not be representative of clinical performance.

  1. Data on file. DWGSRFX058-XXX-XX and DWGSRFX072-XXX-XX.
  2. Data on file. Navien™ catheter IFU, 70675-001 Rev 06/16.
  3. Data on file. TR-NV10813, N= 3
  4. Data on file. TR-NV10812, N= 3