<p>The ManoScan™ ESO high resolution manometry system enables healthcare providers to assess the pressure and motor function of a patient’s esophagus.</p>
Data is depicted in Clouse plots, providing visualization similar to that of radiographic or endoscopic evaluations.2 Topographical visualization may provide information for diagnosis early in the evaluation process.2
Item number | Description | Units per box |
---|---|---|
800022 | ManoScan™ ESO acquisition software | 1 |
409990084 | ManoView™ ESO v3.0.1 analysis software | 1 |
MSS-3599 | ManoShield™ AR disposable catheter sheaths | 10 |
MSS-2155 | ManoShield™ disposable catheter sheaths | 20 |
MSS-4360 | ManoShield™ AR 3D disposable catheter sheaths | 20 |
MSS-4581-3D | ManoShield™ AR 3D disposable catheter sheaths | 10 |
MSC-1286 | High-resolution esophageal catheter 36-channel circumferential solid-state catheter with 4.2 mm diameter, 1.0 cm spacing between adjacent sensors |
1 |
MSC-3885-3D | ManoScan™ 3-D anorectal catheter 16 circumferential sensing regions with 256 total sensors, central balloon inflation lumen, 10 mm diameter solid-state three-dimensional anorectal catheter. Includes three samples of the ManoShield™ disposable catheter sheaths. |
1 |
MSC-3886 | High-resolution esophageal small diameter catheter, 7.5 mm spacing 36-channel circumferential solid-state catheter with 2.75 mm diameter and 7.5 mm spacing between adjacent sensors |
1 |
MSC-3887 | High-resolution esophageal small diameter adult catheter, 10 mm spacing 36-channel circumferential solid-state catheter with 2.75 mm diameter and 10 mm spacing between adjacent sensors |
1 |
MSC-2192 | High-resolution 12 channel anorectal catheter Circumferential solid-state catheter with 4.2 mm diameter, 6 mm spacing between sensors; 10 sphincter sensors and 2 balloon sensors |
1 |
MSC-2195 | High-resolution 8 channel anorectal catheter Circumferential solid-state catheter with 4.2 mm diameter, 6 mm spacing between sensors; 7 sphincter sensors and 1 balloon sensor |
1 |
MSC-3890-Z | High-resolution esophageal catheter with impedance High-resolution solid-state esophageal catheter with 36 channels of circumferential pressure sensors and 18 impedance channels, 4.2 mm |
1 |