Evolut™ FX system

<p>The Evolut™ FX transcatheter aortic valve replacement (TAVR) system sets new expectations for precision, control, and predictability in TAVR procedures.<br> </p>

Features

Design goals

Precision. Control. Predictability.


Optimized stability layer for more predictable deployment


Redesigned tip and increased capsule flexibility for more dilator-like access and to better accommodate the most challenging anatomies


Single-spine shaft for greater flexibility and improved deliverability


Enhanced visualization
Radiopaque markers provide a reference for deployment depth and commissure location.


Performance as compared to Evolut™ PRO+ system in bench testing. Bench testing may not be indicative of clinical performance.


Performance in bench testing

Deployment stability

The Evolut™ FX stability layer increases catheter support during deployment and provides 50% less ventricular movement.


Evolut™ FX conforms to the native anatomy more easily for a 36% improvement in deployment coaxiality.

50%

less ventricular
movement

36%

improvement in
deployment coaxiality


Deliverability

The Evolut™ FX system has a 33% reduction in insertion force (smoother) into simulated vasculature with a more flexible capsule.

Evolut™ FX nosecone

Illustration of the Evolut™ FX nosecone flexible capsule

Evolut™ PRO+ nosecone

Illustration of the Evolut™ PRO+ nosecone flexible capsule


The Evolut™ FX system has a 38% reduction in tracking force in challenging anatomies.

33%

reduction in
insertion force

38%

reduced
tracking force


The Evolut™ FX system increases flexibility for 360° range of motion for greater control.

Illustration showing the range of motion of the Evolut™ PRO+ TAV system
Illustration showing the range of motion of the Evolut™ FX TAV system


† Performance as compared to Evolut™ PRO+ system in bench testing. Bench testing may not be indicative of clinical performance.


Manuals and technical guides

Access instructions for use and other technical manuals in the Medtronic manual library. Search by the product name (e.g., Evolut™) or model number. You may also call 800-961-9055 for a copy of a manual.


Ordering information

Bioprosthesis — Evolut™ FX valve

Item number Valve size (mm) Aortic annulus diameter (mm)
EVOLUTFX-23 23 17/18–20
EVOLUTFX-26 26 20–23
EVOLUTFX-29 29 23–26
EVOLUTFX-34 34 26–30


Loading system — Evolut™ FX loading system

Item number Description
L-EVOLUTFX-2329 Loading system for use with 23, 26, and 29 mm TAV
L-EVOLUTFX-34 Loading system for use with 34 mm TAV


Delivery catheter system — Evolut™ FX delivery catheter system with InLine™ sheath

Item number Description Delivery system size Delivery system working length (cm)
D-EVOLUTFX-2329 Delivery system for use with 23, 26, 29 mm TAV 14 Fr equivalent (6 mm capsule outer diameter) 108
D-EVOLUTFX-34 Delivery system for use with 34 mm TAV 18 Fr equivalent (7.33 mm capsule outer diameter) 108

 

Related links

Get support.

Reach out to LifeLine CardioVascular Tech Support with questions.

Phone877-526-7890

Clinical evidence

The Medtronic CoreValve™/Evolut™ platform is supported by a robust body of clinical evidence. Explore the CoreValve™/Evolut™ clinical success.

Education and resources

Find more detailed TAVR information, educational resources, and tools.

Stay connected.

Follow us on LinkedIn for the latest in TAVR updates.

† Performance as compared to Evolut™ PRO+ system in bench testing. Bench testing may not be indicative of clinical performance.

‡ Measurement for TAV-in-SAV only.