Item number | C304-HIS |
---|---|
Primary curve shape | Deflectable and preshaped |
Secondary curve: Out-of-plane, His shape curve | Yes, preshaped |
Introducer | 9 Fr |
Usable length | 43 cm |
Inner diameter | 5.7 Fr |
Outer diameter | 8.4 Fr |
Integrated valve | No |
Manipulation | Articulation handle |
Hydrophilic coating | No |
Shelf life | 2 years |
Marker band material | 2 gold band markers |
ETO sterilization | Yes |
Pacing leads and delivery systems
SelectSite™ deflectable catheter system
<p>The SelectSite™ deflectable catheter is a steerable system for lead delivery at or near the bundle of His.</p>
Features
Improved reach and enhanced range
- Adjustable curve designed to reach a large variety of patient anatomies† and accommodate challenging anatomical situations, including a large right atrium‡
- Achieves various curve shapes during implant using only this steerable guide catheter
- Handle mechanism secures a desired shape, reducing the need to physically hold the curve in place during the procedure
Stable and supportive
- Rigid proximal portion provides mechanical support and stability for lead delivery and fixation; while the softer distal end minimizes tissue injury
- Catheter deflection is designed to push tip toward the targeted tissue and maintain stability on the septum
- Catheter provides a stable workspace to pass guidewires and leads in the cardiac venous anatomy
- Dual-braided lumen provides stability§
Increased implant success
- C304-HIS catheter design allows the tip to achieve an angle closer to perpendicular in the region of the His-bundle for a higher fixation rate versus the C315-HIS catheter†,‡
- C304-HIS catheter may be used in conjunction with the Medtronic Model 3830 pacing lead
- Catheter body is radiopaque for visibility on fluoroscopy and has improved visualization of the catheter (versus C304-L69) with an additional marker at the distal end
Maneuverability
- Handle mechanism enables tip deflection by transmitting fine movements to the catheter shaft, allowing placement at the bundle of His
- Designed for improved manipulation◊ — deflect for gross movement and torque for minor movement
- Braided, kink-resistant catheter design with multiple transition zones allows for various stiffness characteristics, providing flexibility to navigate curvatures of venous anatomy
Ordering information
Similar products
† Using modeling study of 20 different patient anatomies, selected to include patients with atria ranging from 38–197 mL RA volumes.
‡ Across tested anatomies, the C304-HIS improved fixation success rate in larger RAs with volumes between 110 mL and 139 mL (versus C315).
§ Within the wall thickness of the device lumen is a second braided lumen for the pull wire.
◊ In comparison to C315-HIS catheter.