Ventilator breath delivery
MedEd Bytes
MedEd Bytes is a video series that offers a quick and digestible learning format that can help solidify your understanding of different therapies leveraged in patient monitoring and respiratory interventions. In this series, we’ll cover topics such as capnography waveforms, the technology behind pulse oximetry, modes of ventilation, and more. To stay up to date with the series, please subscribe to our YouTube channel or start watching the series below.
In this educational series, we discuss the different modes of ventilation, triggering and cycling, ventilator patterns, as well as features and software options unique to the Puritan Bennett™ 980 ventilator.
Learn the types of breaths that can be delivered to the patient, what the ventilator allows the patient to do by themselves, and adjuncts to breath delivery provided by the ventilator.
02:11
YouTube
Learn about the four primary components of the ventilator breath cycle: the trigger phase, the inspiratory phase, the cycling phase, and the expiratory phase.
02:20
YouTube
The mandatory ventilator breath can be patient-triggered, using a flow, pressure, or neural signal from the patient, or time-triggered, based on the breathing frequency set on the ventilator by the operator. Learn about the ways a ventilator phase can be initiated.
02:21
YouTube
In this video we learn about control parameters, which are based on pressure, flow, or time, and the part they play in breath inflation.
02:24
YouTube
The term cycle is used to describe the transition from the inspiratory to the expiratory phase of a positive pressure inflation. Learn more about three types of cycling: volume, flow, and time.
02:20
YouTube
The lung inflations provided by mechanical ventilation can be separated into two general types of breaths: spontaneous breaths and assured breaths.
03:00
YouTube
Learn more about some very common spontaneous and assured inflation types: volume control, pressure control, volume-targeted pressure control, pressure support, and volume-targeted pressure support.
01:37
YouTube
Hypoventilation occurs when there is build-up carbon dioxide because of insufficient elimination of the by-product. Learn what the capnography waveform can look like in this scenario.
02:21
YouTube
Learn about the selectable ventilator functions (tube compensation, assured constant airway pressure, leak compensation) superimposed on suitable breath delivery schemes that can modify breath delivery for a patient’s treatment.
01:56
YouTube
It can be challenging to protect your ventilated patient’s comfort, diaphragm, and lungs. Learn how to help your patient direct their breathing while helping you manage patient work of breathing.
02:06
YouTube
Learn how to reduce leak-related auto-triggering and delayed cycling asynchronies during invasive and noninvasive ventilation in neonates to adults.
02:08
YouTube
Neonatal NIV is typically delivered through nasal prongs or a face mask that connects to or is used in place of the breathing circuit wye connector. The resistance of the NIV interface and the leaks common during neonatal NIV cause a difference between the pressures displayed on a ventilator and the pressures delivered through the nose/mouth of the baby. We discuss how to help reduce the uncertainty around effective pressure delivery during NIV for neonates as well as provide more robust disconnect detection of the prongs or mask.
02:18
YouTube
Find out how pressure control can allow for more natural breathing compared to volume control while delivering consistent mean airway pressure (MAP) to the patient.
01:37
YouTube
This episode introduces BiLevel ventilation, how it works, and its clinical benefits, such as spontaneous breathing during all phases of breathing and the potential to improve oxygenation and reduce sedation in your patients.†
02:23
YouTube
Learn about the benefits of noninvasive ventilation as well as how to address triggering, synchrony, and monitoring challenges associated with leaks.
02:06
YouTube
Find out how tube compensation differs from pressure support in the way it helps your spontaneously breathing patients overcome the flow resistance of the artificial airway and potentially reduce their amount of work needed to breathe.
01:53
YouTube
Discover the differences between pressure support and volume support settings on your Puritan Bennett™ 980 ventilator.
01:43
YouTube
In this final episode, learn how delivered pressure is regulated to the lowest pressure that will deliver the user-set tidal volume despite changing lung conditions.
01:45
YouTube
† Please pay close attention to warnings and their associated consequences as described in the Puritan Bennett™ 980 ventilator operator’s manual. The ventilator system is not intended to be a comprehensive monitoring device and does not activate alarms for all types of conditions. Do not operate the ventilator in a magnetic resonance imaging (MRI) environment. Risks associated with using a mechanical ventilator include but are not limited to hypoxemia, hypercarbia, hypocarbia, and infection.