Item number | Description | Units per box |
---|---|---|
SMBTTOVLX | Blunt tip trocar with oval dissection balloon | 3 |
SMSBTOVLX | Structural balloon trocar with oval dissection balloon | 3 |
SMBTTRNDX | Blunt tip trocar with round dissection balloon | 3 |
SMSBTRNDX | Structural balloon trocar with round dissection balloon | 3 |
SMCYLCST | Blunt tip trocar with cylindrical dissection balloon | 3 |
Access and dissection
Spacemaker™ Pro access and dissector system
The Spacemaker™ Pro dissection balloon is indicated for patients undergoing laparoscopic surgery requiring tissue separation of the extraperitoneal space.
Features
Optimized access (compared to Spacemaker™ Plus device)
- Provides easier, one-time access to surgical space, with a uniquely integrated system†,1
- Offers ability to operate in small spaces, with included low-profile 5mm optical trocars†,2
- Expands access to eligible patients, with balloons not made with latex†,1
Optimized dissection (compared to Spacemaker™ Plus device)1
- Enhances visualization, with anatomic balloons and clear cannulas,‡,1,2
- Creates the right space for each procedure, with anatomic balloons1,2
- Facilitates insertion and full balloon deployment, with tailored cannulas1,2
Optimized efficiency (compared to Spacemaker™ Plus device)
- Saves procedural steps with an integrated access and dissection solution§,1,2
- Adapts to your technique, with the option to use as a system or separately1,2
- Offers more choice in technique, while reducing product codes by up to 50%†
Ordering information
Resources
Spacemaker™ Pro system in-service video (06:55)
Spacemaker™ Pro system MICST animation (07:17)
Similar products
-
Spacemaker™ dissection balloonThe Spacemaker™ dissection balloon is primarily indicated for laparoscopic surgery requiring tissue separation of the extraperitoneal space.
-
Spacemaker™ structural balloon trocarThe Spacemaker™ structural balloon trocar is primarily indicated for patients undergoing laparoscopic surgical procedures.
Overinflation of the dissection balloon may cause the balloon to rupture. Do not exceed 40 pumps. Verify mechanical and electrical compatibility of devices from different manufacturers prior to using them together in a procedure. Care must be exercised not to tunnel too deeply. Avoid forcing the balloon in a manner that may cause trauma to nearby organs and structures.
† Compared to Spacemaker™ Plus dissector system or PDB distention balloons.
‡ Compared to Spacemaker™ Plus dissector system.
§ Compared to PDB distention balloons, trocar does not need to be re-inserted or re-positioned.
- Based on internal test report RE00010041, Spacemaker™ Pro device design verification. April 2015.
- Based on internal test report RE00013395, Spacemaker™ Pro device validation report. April 2015.