Item number | Description | Units per box |
---|---|---|
PM7100 | Monitor | 1 |
PMAC71DOC | Monitor docking station | 1 |
PMPAMP71 | Preamplifier | 1 |
PMAC71PS | Power supply | 1 |
PMAC71STAND | Pedestal stand with VESA mount | 1 |
PM71IFTD | Field test device | 1 |
PMAC71RSC | Reusable sensor cable | 1 |
PMAC71RIC | Reusable infant cable | 1 |
Regional oximeters
INVOS™ 7100 regional oximeter
The INVOS™ 7100 regional oximeter is designed to respond quickly to cerebral desaturation events — so you can, too.
Features
The risks of cerebral desaturation events are real.
Major organ morbidity and mortality.1 Renal failure.1 Stroke.1,2 They're just three of several postoperative risks associated with cerebral desaturation events – and they are common and costly. Especially during cardiac surgery.
Timely intervention is key
Regional oximetry can play an important role as a valuable “first alert” because it monitors for hemodynamic changes and deteriorating patient conditions. Using the right monitoring solution can help you identify relevant signals and make more informed clinical decisions.
Because seconds matter
The INVOS™ 7100 cerebral oximetry system can improve your ability to intervene when your patients need you most.
Confidence in your first alert
The INVOS™ 7100 system offers system improvements that were developed using feedback from customers around the world who have used the INVOS™ 5100C system. Those improvements include:
- A detachable, lightweight tablet-style monitor with touchscreen convenience
- An intuitive interface that’s easy to use
- A smaller sensor footprint that makes it usable with the BIS™ monitoring system
More evaluated than any other cerebral/somatic oximeter
Compared to other cerebral oximeters, INVOS™ technology has a significantly greater body of evidence demonstrating performance and positive impact on patient outcomes.
Specifications
INVOS™ 7100 monitor
Size | Weight | Power | Screen size | Screen type | Resolution | Ports |
---|---|---|---|---|---|---|
20 x 30.75 x 5.1 cm (7.87 x 12.1 x 2 in) |
1270 g (2.8 lbs) |
AC power adapter — Li-ion battery (one hour) | 25.7 cm (10.1 in) — measured diagonally | TFT LCD, projected capacitive multi-touch | 1280 x 800 pixels | USB 3.0, USB 2.0, DC In, docking port |
INVOS™ 7100 preamplifier
Size | Weight | Indicator | Cable length | Cable connector | Defibrillation | Operational temperature range | Storage temperature range | Storage relative humidity range |
---|---|---|---|---|---|---|---|---|
12.8 x 8.7 x 2.8 cm (5.04 x 3.43 x 1.1 in) with hook folded down |
294 g (0.65 lbs) |
Reusable sensor cable (RSC) connection prompt | 428.4 cm (14 ft) (approximate) |
Amphenol 8-pin | Defibrillator proof, type BF applied part | 10 C to 35 C | 10 C to 30 C | 10% to 95% |
Ordering information
Resources
Related products
The INVOS™ cerebral oximetry system should not be used as the sole basis for diagnosis or therapy and is intended only as an adjunct in patient assessment.
- Murkin JM, Adams SJ, Novick RJ, et al. Monitoring brain oxygen saturation during coronary bypass surgery: a randomized, prospective study. Anesth Analg. 2007;104(1):51–58.
- Goldman S, Sutter F, Ferdinand F, Trace C. Optimizing intraoperative cerebral oxygen delivery using noninvasive cerebral oximetry decreases the incidence of stroke for cardiac surgical patients. Heart Surg Forum. 2004;7(5):E376–E381.