Item number | Description | Units per box |
---|---|---|
IS | Infant-neonatal rSO2 sensor, less than 40kg | 10 |
Regional oximetry sensors
INVOS™ regional oximetry infant-neonatal sensor
Regional oximetry sensors
INVOS™ regional oximetry infant-neonatal sensor
INVOS™ regional oximetry infant-neonatal sensors are soft, small sensors designed for fragile neonatal skin anywhere on the body.
Description
Regional oximetry sensors for infants and neonates
INVOS™ regional oximetry infant-neonatal sensors are used with the INVOS™ cerebral-somatic oximeter to generate continuous, noninvasive readings of regional blood oxygen levels in up to four site-specific areas chosen by the care team.1
INVOS™ regional oximetry infant-neonatal sensors are applied to the skin’s surface, and are user and patient friendly, making monitoring of ischemic threats to the brain and body safe and easy.2 By reporting venous weighted regional hemoglobin oxygen saturation (rSO2) in tissue directly beneath the sensor, this reflects oxygen remaining after tissue demand has been met.3
Features
- Noninvasive, continuous measurement
- For application anywhere on the body
- For infants and neonates less than 40 kg4
- Contains a gentle, medical-grade, hypoallergenic hydrocolloid patient adhesive4
- Disposable, designed for single use4
- Not made with natural rubber latex4
Specifications
Physical | |
Sensor dimensions | 2.72" (6.9 cm) length x 0.97" (2.5 cm) width |
Adapter cable length | 6.9" (17.5 cm) |
Depth (thickness) | 0.1005" (2.55 mm) |
Weight | 1.1 oz (31 g) |
Sensor cable length | 5 feet (1.5 m) |
Patient adhesive | Hydrocolloid (medical grade) |
Operational | |
Calibration | Precalibrated; no need for user calibration |
Safety class | Continuous operation |
Type | BF class I |
Environmental requirements | |
Operating temperature range | 10 C–35 C |
Storage temperature range | 10 C–30 C |
Transport temperature range | -10 C–50 C up to 72 hours |
Operational relative humidity range | 15%–95% |
Storage relative humidity range | 10%–95% |
Atmospheric pressure range | 61.6 kPa–107.5 kPa |
Storage relative pressure range | 46.5 kPa–107.5 kPa |
Ordering information
Related links
Related products
Similar products
-
INVOS™ regional oximetry adult sensorINVOS™ adult rSO₂ sensors are used to noninvasively monitor site-specific adequacy of perfusion in the brain or body tissue directly beneath the sensors.
-
INVOS™ regional oximetry pediatric sensor
INVOS™ regional oximetry pediatric sensors are applied to the skin’s surface and can be placed on up to four site-specific areas chosen by the care team.
The INVOS™ cerebral oximetry system should not be used as the sole basis for diagnosis or therapy and is intended only as an adjunct in patient assessment.
- Based on internal report 10124168, user interface specification.
- Zorrilla-Vaca A, Healy R, Grant M, et al. Intraoperative cerebral oximetry-based management for optimizing perioperative outcomes: a meta-analysis of randomized controlled trials, Canadian J Anesth.
- Chance B, Cope M. Phase measurement of light absorption and scatter in human tissue, Rev. Sci. Instrum. 69, 3457 (1998).
- INVOS™ infant regional saturation sensor instructions for use. Medtronic; 2020.