Item number | Description | Units per box |
---|---|---|
LF2019 | LigaSure™ exact dissector with nano-coating | 6 |
Open instruments
LigaSure™ exact dissector
<p>The LigaSure™ exact dissector is a surgical dissection device with nonstick nano-coated jaws.</p>
Features
Fine dissection. Balanced handling.
- Balanced design that supports activations with either hand
- Full soft-touch rings
- Cutting trigger that’s aligned with the handle to eliminate interference with wound edge§,2
- Curved jaw to maximize sight line◊,2
- Slim nonstick nano-coated jaw for precise blunt dissection§,2
- Optimized length to provide precise control§,2
- Activation button
A cooler option for fine dissection2
Our new LigaSure™ exaact dissector makes cutting and sealing simple.§,1
Low temperature profile
The LigaSure™ exact dissector is designed to:
- Cool down fast for secure and atraumatic tissue grasping¶,2
- Stay cool over multiple activations2
Precise performance
The fine, curved jaw of the LigaSure™ exact dissector:
- Allows for precision around critical structures‡
- Enhances the ability to work in tight spaces‡,2
- Maximizes the line of sight¶,2
Its jaw also applies equal force on opposing tissue planes for effective blunt dissection.
Balanced handling
Engineered for fine dissection, the LigaSure™ exact dissector offers:
- A working length that’s optimized to provide precise control§,2
- A cutting trigger that’s aligned with the handle, eliminating interference with the wound edge§,2
Improved efficiency
The fast-cooling times of the LigaSure™ exact dissector mean:
- Fewer instrument exchanges#
- More efficient procedures in the OR∆
All delivered with the speed and reliable performance of LigaSure™ vessel sealing technology.
Thyroidectomy procedure using the Ligasure™ exact dissector performed by Dr. Mark S. Sneider, MD
Clinical and economic benefits for thyroidectomies
Frequently asked questions
The LigaSure™ exact dissector is compatible with the Valleylab™ FT10 energy platform.
- 0 seconds to cool down to 60 C after one activation
- 10 seconds to cool down to 60 C after five activations
The device will work with software version 1.1 on the Valleylab ™ FT10 energy platform.
Specifications
Physical characteristics | |
---|---|
General | Sterile, single use |
Jaw tip curvature | 40 degrees |
Jaw length (mm) | 21.6 |
Cut length (mm) | 19.8 |
Seal length (mm) | 20.6 |
Jaw width at tip (mm) | 2 |
Jaw width at base (mm) | 4 |
Instrument length (cm) | 21 |
Foot switching | yes |
Generator compatibility | Valleylab™ FT10 energy platform, Valleylab™ LS10 generator, and ForceTriad™ energy platform |
Ordering information
Resources
Related links
Related products
Similar products
TM* Third-party brands are trademarks of their respective owners.
† Compared to the LigaSure™ small jaw device (16 out of 16 surgeons surveyed agreed) and the Harmonic Focus™*+ device (11 out of 12 surgeons agreed).
‡ 21 out of 22 surgeons surveyed agreed.
§ 22 out of 23 surgeons surveyed agreed.
◊ 23 out of 23 surgeons surveyed agreed.
¶ 19 out of 21 surgeons surveyed agreed.
# 13 out of 14 surgeons agreed.
∆ 11 out of 12 surgeons agreed.
- Based on internal report RE00107711 rev A, Market research: Thermal profile comparison of LigaSure™ exact dissector and the Ethicon Harmonic™* Focus + conducted on porcine tissue. August 2017.
- Based on internal report RE00114823, Validation labs: surgeon evaluation of LigaSure™ exact dissector, nano-coated. July 18–26, 2017.
- Bircan HY, Inal A, Ozcelik U, et al. LigaSure™ versus clamp tie technique for thyroid surgery; decreased operative time versus increased inflammatory effect: a prospective randomized study. Eur Rev Med Pharmacol Sci. 2014;18:1997–2005.
- Hirunwiwatkul P, Tungkavivachagul S. A multicenter, randomized, controlled clinical trial of LigaSure™ small jaw vessel sealing system versus conventional technique in thyroidectomy. Eur Arch Otorhinolaryngol. 2013;270:2109–2114. doi:10.1007/s00405-012-2289–8.
- Kuboki A, Nakayama T, Konno W, et al. New technique using an energy-based device versus conventional technique in open thyroidectomy. Auris Nasus Larynx. 2013;40:558–562. doi:10.1016/j.anl.2013.04.005.
- Testini M, Pasculli A, Di Meo G, et al. Advanced vessel sealing devices in total thyroidectomy for substernal goitre: A retrospective cohort study. Int J Surg. 2016;35:160–164. doi:10.1016/j.ijsu.2016.09.092.
- Uludag SS, Teksoz S, Arikan AE, et al. Effect of energy-based devices on voice quality after total thyroidectomy. Eur Arch Otorhinolaryngol. 2017;10.1007/s00405-016-4444-0. doi:10.1007/s00405-016-4444-0.
- Zhang L, Li N, Yang X, Chen J. A meta-analysis comparing the outcomes of LigaSure™ small jaw versus clamp-and-tie technique or Ethicon Harmonic™* Focus scalpel in thyroidectomy. Medicine (Baltimore). 2017;96:e6141. doi:10.1097/MD.0000000000006141.
- Arowolo OA, Olasehinde O, Adisa AO, et al. Early experience with Ligasure™ thyroidectomy in a Nigeria teaching hospital. Niger J Surg. 2019;25:64–69. doi:10.4103/njs.NJS_40_18.
- Grondal AYK, Hogsbro M, Pryds K, Pedersen HB, Jacobsen H. Intra- and postoperative complications using LigaSure™ small jaw in patients undergoing thyroidectomy: a register-based study. Eur Arch Otorhinolaryngol. 2021;278:4491–4500. doi:10.1007/s00405-021 06685-w.
- Coiro S, Frattaroli FM, De Lucia F, et al. A comparison of the outcome using Ligasure™ small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study. Langenbecks Arch Surg. 2015;400:247–252. doi:10.1007/s00423-014-1270-y.
- Papavramidis TS, Pliakos I, Chorti A, et al. Comparing Ligasure™ exact dissector with other energy devices in total thyroidectomy: a pilot study. Gland Surg. 2020;9: 271–277. doi:10.21037/gs.2020.02.05.
- Dionigi G, Boni L, Rausei S, et al. The safety of energy-based devices in open thyroidectomy: a prospective, randomized study comparing the LigaSure ™ (LF1212) and the Ethicon Harmonic™* Focus . Langenbecks Arch Surg. 2012;397:817–823. doi:10.1007/s00423-011-0898-0.
- Hammad AY, Deniwar A, Al-Qurayshi Z, et al. A prospective study comparing the efficacy and surgical outcomes of harmonic focus scalpel versus Ligasure™ small jaw in thyroid and parathyroid surgery. Surg Innov. 2016;23:486–489. doi:10.1177/1553350616639143.
- Hwang SO, Jung JH, Park HY, Kim WW. A prospective, randomized study between the small jaw and the open thyroidectomy. Otolaryngol Head Neck Surg. 2014;150:943–948. doi:10.1177/0194599814527730.
- Canu GL, Medas F, Podda F, et al. Thyroidectomy with energy-based devices: surgical outcomes and complications-comparison between Harmonic Focus, LigaSure ™ small jaw and Thunderbeat open fine jaw. Gland Surg. 2020;9:721–726. doi:10.21037/gs.2020.03.31.
- Molnar C, Botoncea M, Butiurca VO, et al. Monobloc total thyroidectomy using sealing devices: preliminary results and comparative analysis. Chirurgia (Bucur). 2019;114:668–673. doi:10.21614/chirurgia.114.5.668.
- Chang LY, O’Neill C, Suliburk J, et al. Sutureless total thyroidectomy: a safe and cost-effective alternative. ANZ J Surg. 2011;81:510–514.
- Pons Y, Gauthier J, Ukkola-Pons E, et al. Comparison of LigaSure™ vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy. Otolaryngol Head Neck Surg. 2009;141:496–501. doi:10.1016/j.otohns.2009.06.745.
- Coerper S, Stengl W. Implementation of a vessel sealing device in a centre for thyroid surgery: risk and economic profit. Zentralbl Chir. 2017;10.1055/s-0043-102570. doi:10.1055/s-0043-102570.