Open instruments

LigaSure™ exact dissector

<p>The LigaSure™ exact dissector is a surgical dissection device with nonstick nano-coated jaws.</p>

Features

Fine dissection. Balanced handling.

  1. Balanced design that supports activations with either hand
  2. Full soft-touch rings
  3. Cutting trigger that’s aligned with the handle to eliminate interference with wound edge§,2 
  4. Curved jaw to maximize sight line◊,2
  5. Slim nonstick nano-coated jaw for precise blunt dissection§,2
  6. Optimized length to provide precise control§,2
  7. Activation button
The LigaSure™ exact dissector is a surgical dissection device with nonstick nano-coated jaws.

A cooler option for fine dissection2

Our new LigaSure™ exaact dissector makes cutting and sealing simple.§,1

Low temperature profile 

The LigaSure™ exact dissector is designed to:

  • Cool down fast for secure and atraumatic tissue grasping¶,2
  • Stay cool over multiple activations2

Precise performance

The fine, curved jaw of the LigaSure™ exact dissector:

  • Allows for precision around critical structures
  • Enhances the ability to work in tight spaces‡,2
  • Maximizes the line of sight¶,2

Its jaw also applies equal force on opposing tissue planes for effective blunt dissection.

Balanced handling

Engineered for fine dissection, the LigaSure™ exact dissector offers:

  • A working length that’s optimized to provide precise control§,2
  • A cutting trigger that’s aligned with the handle, eliminating interference with the wound edge§,2

Improved efficiency

The fast-cooling times of the LigaSure™ exact dissector mean:

  • Fewer instrument exchanges#
  • More efficient procedures in the OR

All delivered with the speed and reliable performance of LigaSure™ vessel sealing technology.

LIGASURE

Thyroidectomy procedure using the Ligasure™ exact dissector performed by Dr. Mark S. Sneider, MD

Clinical and economic benefits for thyroidectomies

This is an icon of an analog alarm clock.

Surgical time 

LigaSure™ technology enables:

  • Generally shorter surgical time compared to clamp and tie ligation3–11
  • Shorter or comparable surgical time versus Thunderbeat™* and Harmonic™* scalpels6–8,12–17

   

See an icon to represent pain.

Protect voice function7,12 with less pain†,13

  • LigaSure™ devices have a decreased impact on voice function compared to the Harmonic™* Focus device.7
  • Patients experience less pain when swallowing following thyroidectomy.†,13

   

Save on healthcare costs.

The higher cost of LigaSure™ devices compared to suture ligation are offset by saved surgical time during thyroidectomy plus other savings,18–20 which include:

  • Reduced device costs†,8,15
  • Up to 30% decrease in OR supplies cost†,21
  • Reduced overall surgical costs compared to conventional ligation19

   

Frequently asked questions

The LigaSure™ exact dissector is compatible with the Valleylab™ FT10 energy platform.

  • 0 seconds to cool down to 60 C after one activation
  • 10 seconds to cool down to 60 C after five activations

The device will work with software version 1.1 on the Valleylab ™ FT10 energy platform.

Specifications

Physical characteristics
General Sterile, single use
Jaw tip curvature 40 degrees
Jaw length (mm) 21.6 
Cut length (mm) 19.8 
Seal length (mm) 20.6
Jaw width at tip (mm)
Jaw width at base (mm)
Instrument length (cm) 21 
Foot switching yes
Generator compatibility Valleylab™ FT10 energy platform, Valleylab™ LS10 generator, and ForceTriad™ energy platform

 

Ordering information

Item number Description Units per box
LF2019 LigaSure™ exact dissector with nano-coating 6

Similar products

TM* Third-party brands are trademarks of their respective owners.

† Compared to the LigaSure™ small jaw device (16 out of 16 surgeons surveyed agreed) and the Harmonic Focus™*+ device (11 out of 12 surgeons agreed).

‡ 21 out of 22 surgeons surveyed agreed.

§ 22 out of 23 surgeons surveyed agreed.

◊ 23 out of 23 surgeons surveyed agreed.

¶ 19 out of 21 surgeons surveyed agreed.

# 13 out of 14 surgeons agreed.

∆ 11 out of 12 surgeons agreed.

  1. Based on internal report RE00107711 rev A, Market research: Thermal profile comparison of LigaSure™ exact dissector and the Ethicon Harmonic™* Focus + conducted on porcine tissue. August 2017.
  2. Based on internal report RE00114823, Validation labs: surgeon evaluation of LigaSure™ exact dissector, nano-coated. July 18–26, 2017.

  1. Bircan HY, Inal A, Ozcelik U, et al. LigaSure™ versus clamp tie technique for thyroid surgery; decreased operative time versus increased inflammatory effect: a prospective randomized study. Eur Rev Med Pharmacol Sci. 2014;18:1997–2005.
  2. Hirunwiwatkul P, Tungkavivachagul S. A multicenter, randomized, controlled clinical trial of LigaSure™ small jaw vessel sealing system versus conventional technique in thyroidectomy. Eur Arch Otorhinolaryngol. 2013;270:2109–2114. doi:10.1007/s00405-012-2289–8.
  3. Kuboki A, Nakayama T, Konno W, et al. New technique using an energy-based device versus conventional technique in open thyroidectomy. Auris Nasus Larynx. 2013;40:558–562. doi:10.1016/j.anl.2013.04.005.
  4. Testini M, Pasculli A, Di Meo G, et al. Advanced vessel sealing devices in total thyroidectomy for substernal goitre: A retrospective cohort study. Int J Surg. 2016;35:160–164. doi:10.1016/j.ijsu.2016.09.092.
  5. Uludag SS, Teksoz S, Arikan AE, et al. Effect of energy-based devices on voice quality after total thyroidectomy. Eur Arch Otorhinolaryngol. 2017;10.1007/s00405-016-4444-0. doi:10.1007/s00405-016-4444-0.
  6. Zhang L, Li N, Yang X, Chen J. A meta-analysis comparing the outcomes of LigaSure™ small jaw versus clamp-and-tie technique or Ethicon Harmonic™* Focus scalpel in thyroidectomy. Medicine (Baltimore). 2017;96:e6141. doi:10.1097/MD.0000000000006141.
  7. Arowolo OA, Olasehinde O, Adisa AO, et al. Early experience with Ligasure™ thyroidectomy in a Nigeria teaching hospital. Niger J Surg. 2019;25:64–69. doi:10.4103/njs.NJS_40_18.
  8. Grondal AYK, Hogsbro M, Pryds K, Pedersen HB, Jacobsen H. Intra- and postoperative complications using LigaSure™ small jaw in patients undergoing thyroidectomy: a register-based study. Eur Arch Otorhinolaryngol. 2021;278:4491–4500. doi:10.1007/s00405-021 06685-w.
  9. Coiro S, Frattaroli FM, De Lucia F, et al. A comparison of the outcome using Ligasure™ small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study. Langenbecks Arch Surg. 2015;400:247–252. doi:10.1007/s00423-014-1270-y.
  10. Papavramidis TS, Pliakos I, Chorti A, et al. Comparing Ligasure™ exact dissector with other energy devices in total thyroidectomy: a pilot study. Gland Surg. 2020;9: 271–277. doi:10.21037/gs.2020.02.05.
  11. Dionigi G, Boni L, Rausei S, et al. The safety of energy-based devices in open thyroidectomy: a prospective, randomized study comparing the LigaSure ™ (LF1212) and the Ethicon Harmonic™* Focus . Langenbecks Arch Surg. 2012;397:817–823. doi:10.1007/s00423-011-0898-0.
  12. Hammad AY, Deniwar A, Al-Qurayshi Z, et al. A prospective study comparing the efficacy and surgical outcomes of harmonic focus scalpel versus Ligasure™ small jaw in thyroid and parathyroid surgery. Surg Innov. 2016;23:486–489. doi:10.1177/1553350616639143.
  13. Hwang SO, Jung JH, Park HY, Kim WW. A prospective, randomized study between the small jaw and the open thyroidectomy. Otolaryngol Head Neck Surg. 2014;150:943–948. doi:10.1177/0194599814527730.
  14. Canu GL, Medas F, Podda F, et al. Thyroidectomy with energy-based devices: surgical outcomes and complications-comparison between Harmonic Focus, LigaSure ™ small jaw and Thunderbeat open fine jaw. Gland Surg. 2020;9:721–726. doi:10.21037/gs.2020.03.31.
  15. Molnar C, Botoncea M, Butiurca VO, et al. Monobloc total thyroidectomy using sealing devices: preliminary results and comparative analysis. Chirurgia (Bucur). 2019;114:668–673. doi:10.21614/chirurgia.114.5.668.
  16. Chang LY, O’Neill C, Suliburk J, et al. Sutureless total thyroidectomy: a safe and cost-effective alternative. ANZ J Surg. 2011;81:510–514.
  17. Pons Y, Gauthier J, Ukkola-Pons E, et al. Comparison of LigaSure™ vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy. Otolaryngol Head Neck Surg. 2009;141:496–501. doi:10.1016/j.otohns.2009.06.745.
  18. Coerper S, Stengl W. Implementation of a vessel sealing device in a centre for thyroid surgery: risk and economic profit. Zentralbl Chir. 2017;10.1055/s-0043-102570. doi:10.1055/s-0043-102570.