Electrosurgical generators and monitors

Valleylab™ FT10 electrosurgical generator

<p>The Valleylab™ FT10 electrosurgical generator drives monopolar and bipolar devices, deploying TissueFect™ sensing technology to adjust energy output.</p>

Features

Trust in performance, reliability, and safety

For over 55 years, the Valleylab™ energy portfolio has shown an unwavering commitment to positive patient outcomes through trusted energy delivery, establishing pathways for future innovation in the surgical energy space.

Our proprietary electronics and algorithms allow the Valleylab™ FT10 electrosurgical generator to deliver the highest power consistency.†,‡,2–4

TissueFect™ technology

TissueFect™ sensing technology monitors changes in tissue impedance 434,000 times a second and adjusts energy output accordingly to deliver the appropriate amount of energy for the desired tissue effect.1

Easy-to-read control panel

The Valleylab™ FT10 electrosurgical generator is an intuitive system to use, and the error alerts are easy to understand.†,3

Specifications

Feature Valleylab™ FT10 electrosurgical generator
Performance TissueFect™ reads tissue 434,000 times per second.
Software upgradeable Ethernet connection
Touch screen Single, simplified touchscreen with intuitive controls and information
Electrosurgery modalities Monopolar energy
  • Cut — pure, blend
  • Coag — spray, fulgurate, soft, shared spray, shared fulgurate
Bipolar energy
  • Precise, standard, macro
Bipolar feature Cable compensation reads cable length and width for consistent electrosurgical output.
Dimensions Height: 17.8 cm (7.0 in)
Width: 36.8 cm (14.5 in)
Depth: 46.2 cm (18.2 in)
Weight: 10.1 kg (22.3 lb)

Ordering information

Item number Description Items per box
VLFT10FXGEN Valleylab™ FT10 electrosurgical generator

† As compared with the ForceTriad™ energy platform.

‡ Ex-vivo testing model used to evaluate average additional activation delay time compared between the ForceTriad™ and the Valleylab™ FT10. There is a statistically significant difference between the two generators (p = 0.033) with the Valleylab™ FT10 having lower activation time delays than the ForceTriad™ platform.

  1. Based on internal memo RE00256209 rev A, Valleylab™ FT10 memo control system resolution in VLFT10GEN. March 2020.
  2. Based on internal report R0064457, Verification report LigaSure™ renal bench burst pressure evaluation of the Valleylab™ FT10. May 3, 2015.
  3. Based on internal report RE00005401, Product validation of Valleylab™ FT10 surgeon and nurse evaluation in simulated use. January–February 2015.
  4. Based on internal report RE00005503, Verification report GLP acute animal lab: LigaSure™ preclinical evaluation of Valleylab™ FT10. May 19, 2015.