Item number | Shaft width (mm) | Shaft length (cm) | Tacks per strip | Strips per box |
---|---|---|---|---|
ABSTACK20S | 5 | 18 | 20 | 6 |
ABSTACK30X | 5 | 36 | 30 | 6 |
ABSTACK15 | 5 | 36 | 15 | 6 |
ABSTACK30 | 5 | 36 | 30 | 6 |
Hernia fixation devices
AbsorbaTack™ fixation device
Hernia fixation devices
AbsorbaTack™ fixation device
The AbsorbaTack™ fixation device is intended for fixation of prosthetic material to soft tissue in various minimally invasive and open surgical procedures.
Description
The AbsorbaTack™ device is a sterile, single-use device for fixation of prosthetic material, such as mesh, to soft tissue. The tack is constructed of an absorbable synthetic polyester copolymer derived from lactic and glycolic acid and is dyed with D&C Violet No. 2.
Features
Product design
- Leaves no foreign material behind over time1
- No metal required for fixation 2,3
Fixation strength
- Provides strong temporary mesh fixation4,5
Patient safety
- Potentially fewer adhesions than permanent tack fixation based on a preclinical study†,6
Ordering information
Similar products
-
MaxTack™ motorized fixation deviceThe MaxTack™ motorized fixation device provides a push-button firing mechanism, tacks, and an in-line handle design for minimally invasive hernia fixation.
-
ProTack™ fixation deviceThe ProTack™ fixation device is used to fix prosthetic material and approximate tissue in various endoscopic surgical specialties such as hernia repair.
-
ReliaTack™ articulating reloadable fixation deviceThe ReliaTack™ fixation device is intended for fixation of prosthetic material to soft tissue in minimally invasive and open surgical hernia repair procedures.
-
Stat Tack™ fixation device
The Stat Tack™ 5 mm fixation device is indicated to affix prosthetic material or approximate tissue in a variety of endoscopic or other surgical procedures.
-
Tacker™ fixation deviceThe Tacker™ fixation device is indicated to affix prosthetic material or approximate tissue in a variety of endoscopic or other surgical procedures.
† Based on preclinical data, not necessarily indicative of human clinical outcomes.
- Based on internal report RE00003170-2, ReliaTack™ phase II In-vitro mass loss. July 2016.
- Based on internal report Q0512-ISO 2E, L1 absorbable polymer. June 2010.
- Based on internal report 3009557K. AbsorbaTack™ Tack Print. May 2007.
- Based on internal report TD1025, Mechanical evaluation of AbsorbaTack™, ProTack™, and SECURESTRAP™* in shear mode using foam media. January 2012.
- Colak E, Ozlem N, Kucuk O. Prospective randomized trial of mesh fixation with absorbable versus nonabsorbable tacker in laparoscopic ventral incisional hernia repair. Int J Clin Exp Med. 2015;8(11):21611–21616.
- Hollinsky C., Kolbe T., Walter I. et al. Tensile strength and adhesion formation of mesh fixation systems used in laparoscopic incisional hernia repair. Surg Endosc. 2010;24(6):1318–1324.