Drug-eluting stents

Resolute Onyx™ drug-eluting stent (DES)

Drug-eluting stents

Resolute Onyx™ drug-eluting stent (DES)

The Resolute Onyx™ drug-eluting stent (DES) is used in complex percutaneous coronary intervention (PCI).

Description

Resolute Onyx™ drug-eluting stent (DES) offers flexibility,1 conformability,1 a 2.0 mm to 5.0 mm size matrix, and is indicated for high bleeding risk patients and labeled for one-month DAPT.2

Product specifications

Stent design Continuous sinusoid technology with core wire technology 
Polymer and drug BioLinx™ polymer and zotarolimus 
Delivery system Resolute Onyx™ delivery system 
Catheter distal OD (Fr) 2.00–4.00 mm: 2.7 
4.50–5.00 mm: 3.2
Catheter distal OD (in)  2.00–4.00 mm: 0.036
4.50–5.00 mm: 0.042 
Crowns Small vessel (2.00–2.50 mm): 6.5 
Medium vessel (2.75–3.00 mm): 8.5
Large vessel (3.50–4.00 mm): 9.5 
Extra-large vessel (4.50–5.00 mm): 10.5
Stent material  Shell: Cobalt alloy, Core: Pt–Ir
Strut thickness  2.00–4.00 mm: 81 μm (0.0032 in)
4.50–5.00 mm: 91 μm (0.0036 in) 
Base coating Parylene C 
Polymer coating BioLinx™ polymer 
Drug density Zotarolimus (~1.6 μg/mm2) 
Balloon material Enhanced Fulcrum™ material 
Platform RX (2.00–5.00 mm) and OTW (2.00–4.00 mm) 
Catheter length (cm) 140 
Nominal pressure (atm) 12 
Rated burst pressure (atm) 2.00–4.00 mm: 18 
4.50–5.00 mm: 16
Marker band material  Platinum iridium

Broad size matrix

Diameter (mm) Stent length (mm) MSID (mm)
2.00 8 12 15 18 22 26 30 3.50
2.25 8 12 15 18 22 26 30 34 38 3.50
2.50 8 12 15 18 22 26 30 34 38 3.50
2.75 8 12 15 18 22 26 30 34 38 4.00
3.00 8 12 15 18 22 26 30 34 38 4.00
3.50 8 12 15 18 22 26 30 34 38 5.00
4.00 8 12 15 18 22 26 30 34 38 5.00
4.50 12 15 18 22 26 30 6.00
5.00 12 15 18 22 26 30 6.00
Maximum stent inner diameter (MSID)  

4.50 and 5.00 mm sizes are not available in OTW.
Resolute Onyx™ stents should not be expanded to a diameter beyond the listed MSID.

Ordering information

Resolute Onyx™ DES rapid exchange (RX) coronary stent system

Resolute Onyx™ DES over-the-wire (OTW) coronary stent system


TM* Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company. 


  1. Third-party modeling and analysis on file at Medtronic (Mortier Conformability Testing). May not be indicative of clinical performance. Evaluated the following stent platforms (3.0 mm): Resolute Onyx DES, Synergy™* DES, and XIENCE Alpine™* DES (Multi-Link 8 BMS platform).
  2. Resolute Onyx™ DES instructions for use.