• Filter By:
  • All Products
  • Laparoscopic Inguinal
  • Laparoscopic Ventral
  • Open Inguinal
  • Open Ventral

Symbotex™ Composite Mesh

Product Details

Symbotex™ composite mesh provides surgeons improved ease of use, with easy mesh deployment and placement within the abdominal cavity. It also brings optimal performance for patients with excellent tissue integration and minimized visceral attachments.

Symbotex™ mesh is available in a large variety of shapes and sizes for laparoscopic hernia repair, with specific subranges dedicated to laparoscopic and open surgery.

ORDER INFORMATION
Order Code Description Unit of Measure Quantity
SYM9 Symbotex™ Composite Mesh/9 cm diameter Box 1
SYM12 Symbotex™ Composite Mesh/12 cm diameter Box 1
SYM15 Symbotex™ Composite Mesh/15 cm diameter Box 1
SYM1510 Symbotex™ Composite Mesh/15 x 10 cm Box 1
SYM2015 Symbotex™ Composite Mesh/20 x 15 cm Box 1
SYM2520 Symbotex™ Composite Mesh/25 x 20 cm Box 1
SYM3020 Symbotex™ Composite Mesh/30 x 20 cm Box 1
SYM3728 Symbotex™ Composite Mesh/37 x 28 cm Box 1
SYM4232 Symbotex™ Composite Mesh/42 x 32 cm Box 1
SYM2012E Symbotex™ Composite Mesh/20 x 12 cm Box 1
SYM1710E Symbotex™ Composite Mesh/17 x 10 cm Box 1
SYM2515E Symbotex™ Composite Mesh/25 x 15 cm Box 1
SYM3420E Symbotex™ Composite Mesh/34 x 20 cm Box 1
SYM4024E Symbotex™ Composite Mesh/40 x 24 cm Box 1
SYM8OS Symbotex™ Composite Mesh/8 cm diameter Box 1
SYM1510OS Symbotex™ Composite Mesh/15 x 10 cm Box 1
SYM2015OS Symbotex™ Composite Mesh/20 x 15 cm Box 1
SYM2520OS Symbotex™ Composite Mesh/25 x 20 cm Box 1
SYM3020OS Symbotex™ Composite Mesh/30 x 20 cm Box 1

ProGrip™ Laparoscopic Self-Fixating Mesh

Product Details

Designed to address key issues in laparoscopic inguinal hernia repair, ProGrip™ laparoscopic self-fixating mesh delivers tack-free fixation over the entire anatomy([FOOTNOTE=0Kolbe, T, Hollinsky, C, Walter, I, Joachim, A, and Rülicke, T. Influence of a new self-gripping hernia mesh on male fertility in a rat model. Surgical Endoscopy 2010; 24: 455-461.],[ANCHOR=],[LINK=]) thus eliminating the pain([FOOTNOTE=Laxa, B, and Jacob, B. An ongoing prospective study evaluating self-gripping mesh (Parietex ProGrip™) without additional fixation during laparoscopic total extraperitoneal (TEP) inguinal hernia repair: initial analysis. IHS 2012 P1620.],[ANCHOR=],[LINK=]),([FOOTNOTE=5Birk, D. Self-gripping mesh in laparoscopic inguinal hernia repair. Technique and clinical outcome of 96 operations. IHS 2012 P-1654.],[ANCHOR=],[LINK=]) and cost([FOOTNOTE=Edwards, C. Self-fixating mesh is safe and feasible for laparoscopic inguinal hernia repair. Surgical Endoscopy and Other Interventional Techniques. Conference: 2011 Scientific Session of the Society of American Gastrointestinal and Endoscopic Surgeons, SAGES San Antonio, TX United States. Conference Start: 20110330 Conference End: 20110402. 25: S324.],[ANCHOR=],[LINK=]) associated with traditional fixation.

ORDER INFORMATION
Order Code Description Unit of Measure Quantity
LPG1510 ProGrip™ Laparoscopic Self-Fixating Mesh, 10 x 15 Box 1
LPG1510X2 ProGrip™ Laparoscopic Self-Fixating Mesh, 10 x 15 Box 2
LPG1510AR ProGrip™ Laparoscopic Self-Fixating Mesh, Right Anatomical Box 1
LPG1510AL ProGrip™ Laparoscopic Self-Fixating Mesh, Left Anatomical Box 1
LPG1510AK2 ProGrip™ Laparoscopic Self-Fixating Mesh, Bilateral Anatomical Box 2

Parietex™ Composite Ventral Patch

Product Details

Parietex™ Composite ventral patch is a mesh specifically designed for small ventral hernia repair. The shape, size, and the specific fixation and deployment system have been designed for optimal abdominal wall conformability and easy deployment and fixation([FOOTNOTE=Based on internally sponsored preclinical study report #0506-141814, Report 10 days and 4 weeks implantation study in a porcine model, March 2012, and report #0506-141814, Report 10 days and 4 weeks implantation study – amendment 1, June 2012.],[ANCHOR=],[LINK=]).

Parietene™ DS Composite Mesh

Product Details

A strong,([FOOTNOTE=Based on internal preclinical test report #T2294CR212, Design validation of Parietene™ DS composite mesh in surgeon labs: Evaluation performed through users test and questionnaire in a simulated use environment using a porcine model (n=7 surgeons). September 2016.],[ANCHOR=],[LINK=]) easy-to-use mesh for open and laparoscopic ventral hernia repairs.([FOOTNOTE=Based on internal preclinical report #T2294CR212. Design validation of Parietene™ DS composite mesh in surgeon labs: Feedback collected from seven independent surgeons in a simulated use environment using a porcine model. September 2016.],[ANCHOR=],[LINK=])

On one side, a macroporous mesh to repair ventral hernia defects. On the other, an absorbable synthetic film to minimize unwanted tissue attachment.([FOOTNOTE=Based on NAMSA study #198929, Minimizing tissue attachment barrier performance, local tissue effects, and tissue integration of Parietene DS composite mesh in a rat cecal abrasion model. Based on occurrencerates of cecal soft tissue attachment to the mesh through macroscopic observations in the rat (n=18 test articles vs. n=12 bare mesh; p<0.05). October 2016.],[ANCHOR=],[LINK=]),†

Two unique sides. One unique mesh.

Versatex™ Monofilament Mesh

Product Details

A mesh designed to offer a balanced combination of macroporosity, surface density, and mechanical strength for successful hernia repair.

Order Information
Order Code Description Unit of Measure Quantity
VTX1106 Versatex™ Monofilament Mesh/11 x 6 cm Box 1
VTX1106X3 Versatex™ Monofilament Mesh/11 x 6 cm Box 3
VTX1510 Versatex™ Monofilament Mesh/15 x 10 cm Box 1
VTX1510X3 Versatex™ Monofilament Mesh/15 x 10 cm Box 3
VTX1515 Versatex™ Monofilament Mesh/15 x 15 cm Box 1
VTX1515X3 Versatex™ Monofilament Mesh/15 x 15 cm Box 3
VTX1515M Versatex™ Monofilament Mesh/15 x 15 cm Box 1
VTX1515MX3 Versatex™ Monofilament Mesh/15 x 15 cm Box 3
VTX2020M Versatex™ Monofilament Mesh/20 x 20 cm Box 1
VTX3030M Versatex™ Monofilament Mesh/30 x 30 cm Box 1
VTX4530M Versatex™ Monofilament Mesh/45 x 30 cm Box 1
VTX5050M Versatex™ Monofilament Mesh/50 x 50 cm Box 1

Parietene™ Macroporous Mesh

Product Details

Parietene™ macroporous mesh has been designed for a surgeon's ease of use during hernia repair procedures([FOOTNOTE=Based on internal test report #T2291CR044, Physical and mechanical properties of Parietene™ macroporous mesh.],[ANCHOR=],[LINK=]). A Polypropylene microporous based mesh.

While there are many options when it comes to hernia repair, we continue to lead the way in developing hernia repair products that strike the right balance between performance, ease-of-use and cost-effectiveness.

Parietene™ macroporous mesh is one of our latest high-quality mesh that helps facilitate seamless surgical procedures with successful patient outcomes†,1,([FOOTNOTE=Based on internal test report #T2291CR037, Parietene™ macroporous mesh evaluation by surgeons for design validation. June 13, 2014.],[ANCHOR=],[LINK=])

Order Information

Features:

Macroporous Structure

Large pores (2.0 x 2.4 mm)†,([FOOTNOTE=Based on internal test report #T2291CR050a, Designed for improved visualization during placement. July 23, 2014.],[ANCHOR=],[LINK=])

Mechanical Strength

Macroporous design with no compromise of strength for open inguinal and open ventral extraperitoneal hernia repair†,([FOOTNOTE=Based on internal test report #T2291CR044, Physical and mechanical properties of Parietene™ macroporous mesh],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #T2291CR031a, Parietene™ macroporous mesh (type P12 textile) vs. Prolene™* soft polypropylene mesh.],[ANCHOR=],[LINK=])

Balanced Knitting Construct

Provides easy mesh handling, abdominal wall conformability and can be trimmed to size without fraying†,1,2,([FOOTNOTE=Based on internal test report #T2291CR049A, Ability to be trimmed to size without fraying. July 17, 2014.],[ANCHOR=],[LINK=])

Surface Density

Optimal surface density of 46g/m2 †,([FOOTNOTE=Bringman S, Wollert S, Osterberg J, et al. Three-year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia. Br J Surg. 2006;93(9):1056-9.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #T2291CR059a, Parietene™ macroporous mesh (type P12 textile) vs. Prolene™* soft polypropylene mesh. May 12, 2014.],[ANCHOR=],[LINK=]),([FOOTNOTE=Deeken CR, Abdo MS, Frisella MM, Matthews BD. Physicomechanical evaluation of polypropylene, polyester, and polytetrafluoroethylene meshes for inguinal hernia repair. J Am Coll Surg. 2011;212(1):68-79.],[ANCHOR=],[LINK=])

Transparent

Improved visualization to aid mesh placement and fixation†,([FOOTNOTE=Based on internal test report #T2291CR050a, Designed for improved visualization during placement. July 23, 2014.],[ANCHOR=],[LINK=])

Memory Shape

The right balance between rigidity and softness†,2

ORDER INFORMATION
Order Code Description Dimensions Quantity
Ventral      

PPM2020

PPM2020X3

Parietene™ Macroporous Mesh 20x20 cm

box of 1

box of 3

PPM3030

PPM3030X3

Parietene™ Macroporous Mesh 30x30 cm

box of 1

box of 3

PPM4530

PPM4530X3

Parietene™ Macroporous Mesh 45x30 cm

box of 1

box of 3

Inguinal      

PPM1106

PPM1106X3

PPM1106X6

Parietene™ Macroporous Mesh 11x6 cm

box of 1

box of 2

box of 3

PPM1508

PPM1508X3

PPM1508X6

Parietene™ Macroporous Mesh 15x7.5 cm

box of 1

box of 3

box of 6

PPM1510

PPM1510X3

PPM1510X6

Parietene™ Macroporous Mesh 15x10 cm

box of 1

box of 3

box of 6

PPM1515

PPM1515X3

PPM1515X6

Parietene™ Macroporous Mesh 15x15 cm

box of 1

box of 3

box of 6

PPMK1106

PPMK1106X3

PPMK1106X6

Parietene™ Macroporous Mesh 11x6 cm

box of 1

box of 3

box of 6

PPMK1508

PPMK1508X3

PPMK1508X6

Parietene™ Macroporous Mesh 15x7.5 cm

box of 1

box of 3

box of 6

ProGrip™ Self-Gripping Polyester Mesh

Product Details

ProGrip™ self-gripping mesh — a proven technology in tissue reinforcement for nearly a decade — is now helping prevent hernias after laparotomies.([FOOTNOTE=Blazquez Hernando LA, Garcıa-Urena MA, Lopez-Monclus J, et al. Prophylactic mesh can be used safely in the prevention of incisional hernia after bilateral subcostal laparotomies. Surgery. 2016;160(5):1358–1366.],[ANCHOR=],[LINK=]),([FOOTNOTE=Sværdborg M, Damsgaard TE. Donor-site morbidity after pedicled TRAM breast reconstruction: a comparison of two different types of mesh. Ann Plast Surg. 2013;71],[ANCHOR=],[LINK=])

Order Information

Features

We want to help patients avoid the pain of incisional hernias, and save healthcare systems the time and expense of having to treat them. ProGrip™ self-gripping poluester mesh does both.

ProGrip™ self-gripping mesh:

Provides immediate tension-free fixation on the entire surface of the mesh — and offers surgical efficiencies and patient benefits.([FOOTNOTE=Hopson SB, Miller LE. Open ventral hernia repair using ProGrip™ self-gripping mesh. Int J Surg. 2015;23(Pt A):137–140.],[ANCHOR=],[LINK=]),([FOOTNOTE=Kapischke M, Schulze H, Caliebe A. Self-fixating mesh for the Lichtenstein procedure: a prestudy. Langenbecks Arch Surg. 2010;395(4):317–322. This study was conducted with Parietene ProGrip™ mesh.],[ANCHOR=],[LINK=])

It does this by combining monofilament polyester with a resorbable polylactic acid (PLA) microgrip technology. So surgeons get immediate fixation that is strong, durable, and comfortable4,([FOOTNOTE=Hollinsky C, Kolbe T, Walter I, et al. Comparison of a new self-gripping mesh with other fixation methods for laparoscopic hernia repair in a rat model. J Am Coll Surg. 2009;208(6):1107– 1114. This study was conducted with Parietene ProGrip™ mesh.],[ANCHOR=],[LINK=]),([FOOTNOTE=Chastan P. Tension free open inguinal hernia repair using an innovative self-gripping semi-resorbable mesh. Hernia (2009) 13:137–142 DOI 10.1007/s10029-008-0451-4 J Minim Access Surg. 2006;2(3):139–143. This study was conducted with Parietene ProGrip™ mesh.],[ANCHOR=],[LINK=])

Semi-Resorbable Mesh

Fifty percent of material left after PLA absorption([FOOTNOTE=Based on internal test report #RAT021, PLA degradation report. 2014],[ANCHOR=],[LINK=])

Macroporosity

Favors better tissue integration and supports a lower foreign body reaction ([FOOTNOTE=Weyhe D, Cobb W, Lecuivre J, et al. Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage: systematic analysis of key parameters of meshes in a novel minipig hernia model. Int J Surg. 2015;22:46–53.],[ANCHOR=],[LINK=])-([FOOTNOTE=Based on internal test report #Type GT8 textile TEX014, justifying for the pore size. 2015.],[ANCHOR=],[LINK=])

Resorbable Microgrips

Provide immediate fixation with limited need for additional fixation1,3,([FOOTNOTE=Verhelst J, de Goede B, Kleinrensink GJ, Jeekel J, Lange JF, van Eeghem KH. Open incisional hernia repair with a self-gripping retromuscular Parietex™ mesh: a retrospective cohort study. Int J Surg. 2015;13:184–188.],[ANCHOR=],[LINK=])

Dextile™ Anatomical Mesh

Product Details

The benefits of real anatomical design([FOOTNOTE=Based on internal test report #43008CR268, Design output file Merlin. February 2019.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on Medtronic patent #US-20180318057-A1, Prosthesis for inguinal hernia repair. November 2018.],[ANCHOR=],[LINK=])

The uniquely designed Dextile™ anatomical mesh is an easy-to-use solution that can provide the positive patient outcomes clinicians want.([FOOTNOTE=Based on internal report #43008CR339, Support for marketing claims related to surface of Dextile™ anatomical mesh vs. competitors. August 2019.],[ANCHOR=],[LINK=])

Parietex ProGrip™ Self-Fixating Mesh

Show product details

Parietex ProGrip™ self-fixating mesh delivers security, patient comfort and ease of use. Its advanced microgrip technology provides immediate fixation([FOOTNOTE=Data on file.],[ANCHOR=],[LINK=]) of the entire mesh surface for a secure repair and even distribution of tension for patient comfort. Designed for ease of use, the resorbable polylactic acid (PLA) microgrips enable surgeons to position and place the mesh in under 60 seconds([FOOTNOTE=Philippe Chastan, MD (2006). “Tension-Free Open Inguinal Hernia Repair Using an Innovative Self-Gripping Semi-Resorbable Mesh.” Journal of Minimal Access Surgery; pp 139-43.],[ANCHOR=],[LINK=]), without the use of additional fixation([FOOTNOTE=Additional fixation is at the surgeon’s discretion.],[ANCHOR=],[LINK=]). Surgeons and patients can depend on a secure repair with the potential for greater patient comfort.

All Parietex™ products are created from a macroporous polyester material which produce superior cellular proliferation when compared to polypropylene mesh in vitro.([FOOTNOTE=Lefranc, O., Codoro, C., Vernier, A., Hadba, A., Gravagna, P. and Therin, M. (2009). “PET vs. PP Mesh Constructs and Their Influence on L929 Fibroblasts Adhesion and Proliferation.” EHS/AHS. Springer. Berlin, Hernia. 13: 64-72.],[ANCHOR=],[LINK=])

View Order Information

Order Information
Order Code Description Unit of Measure Quantity
TEM1208GR Parietex ProGrip™ precut with flap right side 12 x 8 cm (4.7”x 3”) Box 1
TEM1208GL Parietex ProGrip™ precut with flap left side 12 x 8 cm (4.7”x 3”) Box 1
TEM1409GR Parietex ProGrip™ precut with flap right side 14 x 9 cm (5.5”x 3.5”) Box 1
TEM1409GL Parietex ProGrip™ precut with flap left side 14 x 9 cm (5.5”x 3.5”) Box 1
TEM1509G Parietex ProGrip™ rectangular mesh 15 x 9 cm (6”x 3.5”) Box 1
TEM1515G Parietex ProGrip™ rectangular mesh 15 x 15 cm (6”x 6”) Box 1

Parietex™ Optimized Composite (PCOx) Mesh

Product Details

Parietex™ Optimized Composite (PCOx) mesh offers a resorbable collagen barrier on one side to limit visceral attachments and a three-dimensional polyester knit structure on the other to promote differentiated tissue ingrowth and ease of use.

Based on the proven performance of original PCO, PCOx is the next generation of Parietex™ Composite mesh. It is engineered to better address surgeon and patient needs in laparoscopic ventral hernia repair. The new design incorporates a more resistant barrier and a proprietary textile design with better visibility and increased strength([FOOTNOTE=“Comparative study of textile tear and suture strength: Parietex™ Optimized Composite vs Parietex™ Composite.” Covidien internal test report 1003CR053.],[ANCHOR=],[LINK=]).

PCOx mesh promotes rapid abdominal wall integration([FOOTNOTE=Evaluation of the local tissue effects and tissue attachment minimization in a rat caecal adhesion model. BioMatech (NAMSA), France.],[ANCHOR=],[LINK=]), minimizes visceral attachments([FOOTNOTE=Gonzalez et al. Resistance to adhesion formation: A comparative study of treated and untreated mesh products placed in the abdominal cavity. Hernia (2004) 8: 213–219. This study is sponsored by Covidien. Dr. Ramshaw is a current consultant of Covidien. Dr. Rodeheaver is a former consultant of Covidien.],[ANCHOR=],[LINK=]) and facilitates strong tack fixation16.

Order Information

Order Information
Order Code Description Unit of Measure Quantity
PCO9FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 9 cm Round

 

Box 1
PCO12FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 12 cm Round Box 1
PCO15FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 15 cm Round Box 1
PCO20FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 20 cm Round Box 1
PCO1510FX Parietex Optimized Composite (PCOx) 15cm x 10cm with Fixation Sutures Box 1
PCO2015FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 20 x 15 cm Rectangle Box 1
PCO2520FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 25 x 20 cm Rectangle Box 1
PCO3020FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 30 x 20 cm Rectangle Box 1
PCO3728FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 37 x 28 cm Rectangle Box 1
PCO9X Parietex Optimized Composite (PCOx) 9 cm Round Box 1
PCO12X Parietex Optimized Composite (PCOx) 12 cm Round Box 1
PCO15X Parietex Optimized Composite (PCOx) 15 cm Round Box 1
PCO20X Parietex Optimized Composite (PCOx) 20 cm Round Box 1
PCO1510X Parietex Optimized Composite (PCOx) 15 cm x 10 cm Box 1
PCO2015X Parietex Optimized Composite (PCOx) 20 cm x 15 cm Box 1
PCO2520X Parietex Optimized Composite (PCOx) 25 cm x 20 cm Box 1
PCO3020X Parietex Optimized Composite (PCOx) 30 cm x 20 cm Box 1
PCO3728X Parietex Optimized Composite (PCOx) 37 cm x 28 cm Box 1

Parietex™ Plug and Patch System

Product Details

The latest addition to the Parietex™ family of synthetic mesh is easy to use, allowing surgeons to maintain their proven technique and designed to deliver enhanced patient comfort and intra-operative security through its unique design.

  • Easy to Use: Designed for the standard plug and patch technique.
  • Effective: Developed for the proven plug and patch repair that yields low recurrence rates while providing consistent reproducible results([FOOTNOTE=Zhao, G. (2009) Open Mesh Techniques for Inguinal Hernia Repair: A Meta-Analysis of Randomized Controlled Trials. Annals of Surgery; Vol. 250, Number 1, July 2009.],[ANCHOR=],[LINK=]).
  • Conforms to Defect: Resorbable microgrips enable plug to conform to the defect size and shape while providing additional security prior to suture fixation([FOOTNOTE=The disk must be adequately fixated in order to minimize the risk of migration. We recommend the use of nonabsorbable fixation.],[ANCHOR=],[LINK=]).
Order Information

Order Information
Order Code Description Unit of Measure Quantity
PNP6X3 Parietex™ Plug and Patch System - 6.5 cm round plug with keyhole patch Box 3
PNP8X3 Parietex™ Plug and Patch System - 8 cm round plug with keyhole patch Box 3

Parietex™ Optimized Composite Open Skirt (PCO OSx) Mesh

Product Details

Parietex™ Optimized Composite Open Skirt (PCO OSx) mesh provides a new level of control during open ventral hernia repair. The open skirted (OS) design has increased rigidity for easier handling during implantation in open incisional and ventral hernia repair.

The skirted flap on the parietal side of the mesh allows for more easily accessible fixation points in the open approach. The skirt provides an area of fixation protected from the viscera on one side and allows fixation to the abdominal wall without disrupting the collagen film.

Order Information

Order Information
Order Code Description Unit of Measure Quantity
PCO1510OSX Skirted Polyester Mesh with Absorbable Collagen Film, 15 x 10 cm Box 1
PCO2015OSX Skirted Polyester Mesh with Absorbable Collagen Film, 20 x 15 cm Box 1
PCO2520OSX Skirted Polyester Mesh with Absorbable Collagen Film, 25 x 20 cm Box 1

Parietex™ Composite (PCO) Parastomal Mesh

Product Details

Parietex™ Composite (PCO) parastomal mesh is a monofilament mesh providing a custom design for parastomal hernia repair. While ordinary meshes carry the risk of in-growth into the bowel, Parietex™ Composite is coated with a protective collagen-based film to help prevent tissue attachment. Its unique design provides for easy placement of the mesh for parastomal hernia repair.

All Parietex™ products are created from a macroporous polyester material whose properties invite healthy tissue integration and mesh compliance while reducing encapsulation.([FOOTNOTE=William S. Cobb, MD; Kent W. Kercher, MD; and B. Todd Heniford, MD. “The Argument for Lightweight Polypropylene Mesh in Hernia Repair.” Surgical Innovation, Vol 12, No 1 (March), 2005: pp 63-69.],[ANCHOR=],[LINK=])

Order Information

Order Information
Order Code Description Unit of Measure Quantity
PCOPM15H35 Monofilament Polyester with Absorbable Collagen Film for Direct Stomies, 15 cm/35 mm Box 1
PCOPM15H50 Monofilament Polyester with Absorbable Collagen Film for Direct Stomies, 15 cm/50 mm Box 1

Parietex™ Composite Hiatal (PCO 2H) Mesh

Product Details

Parietex™ Composite (PCO) hiatal mesh makes the surgical treatment of gastroesophageal reflux disease (GERD) and hiatal hernia viable. While ordinary meshes can carry the risk of in-growth into the esophagus, Parietex™ Composite is coated on one side with a protective collagen-based film to help minimize tissue attachment. Its unique design provides for easy placement of the mesh for hiatal hernia repair.

All Parietex™ products are created from a macroporous polyester material whose properties invite healthy tissue integration and mesh compliance while reducing encapsulation.21

Order Information

Order Information
Order Code Description Unit of Measure Quantity
PCO2H1 Polyester with Absorbable Collagen Film, Heart-Shaped for Hiatal Hernia, 8 x 8 cm (3.1" x 3.1") Box 1
PCO2H3 Polyester with Absorbable Collagen Film, Horseshoe-Shaped for Hiatal Hernia, 9 x 8 cm (3.6" x 3.1") Box 1

Parietex™ Hydrophilic Anatomical Mesh

Product Details

Parietex™ mesh provides a custom-designed mesh for laparoscopic inguinal hernia repair. It combines Parietex™ 2D weave with Parietex™ 3D weave.

The 2D weave is lightweight and macroporous with a design that is rigid, making it ideal for laparoscopic applications due to its handling properties.

The 3D weave is also a lightweight, macroporous mesh but has a design that provides compliance and softness. This softness allows for gentle placement over sensitive nerve and vessel structures in the inguinal area.

All Parietex™ products are created from a macroporous polyester material whose properties invite healthy tissue integration and mesh compliance while reducing encapsulation.21

Order Information

Order Information
Order Code Description Unit of Measure Quantity
TECT1510ADP2L Parietex™ Hydrophilic Anatomical Mesh Left Side, Polyester, 15 x 10 cm Box 1
TECT1612AL Parietex™ Hydrophilic Anatomical Mesh Left Side, Polyester, 16 x 12 cm Box 1
TECT1510ADP2R Parietex™ Hydrophilic Anatomical Mesh Right Side, Polyester, 15 x 10 cm Box 1
TECT1510AL Parietex™ Hydrophilic Anatomical Mesh, Left Side, Polyester, 15 x 10 cm Box 1
TECT1510AR Parietex™ Hydrophilic Anatomical Mesh, Right Side, Polyester, 15 x 10 cm Box 1
TECT1510ADPL Left anatomical mesh with suture (6" x 4") Box 1
TECT1510ADPR Right anatomical mesh with suture (6" x 4") Box 1
TECT1612AR Parietex™ Hydrophilic Anatomical Mesh Right Side, Polyester, 16 x 12 cm Box 1

Parietex™ Flat Sheet Mesh

Product Details

Parietex™ flat sheet mesh comes in both 2D weaves (TEC) and 3D weaves (TET) designs.

The 2D weave is a lightweight, macroporous mesh with a design that is rigid, making it ideal for laparoscopic applications due to its handling properties.

The 3D weave is also a lightweight, macroporous mesh but has a design that provides softness. This 3D weave allows for compliance and isometric movement with the patient. Its macroporous nature provides optimal cell ingrowth.

All Parietex™ products are created from a macroporous polyester material whose properties invite healthy tissue integration and mesh compliance while reducing encapsulation.21

Order Information

Order Information
Order Code Description Unit of Measure Quantity
TEC1309 Parietex™ Hydrophilic 2-Dimensional Mesh, Polyester, 13 x 9 cm Box 1
TEC1510 Parietex™ Hydrophilic 2-Dimensional Mesh, Polyester, 15 x 10 cm Box 1
TEC1515 Parietex™ Hydrophilic 2-Dimensional Mesh, Polyester, 15 x 15 cm Box 1
TEC2020 Conventional mesh square, Polyester, 20 x 20 cm (8" x 8") Box 1
TEC3030 Conventional mesh square, Polyester, 30 x 30 cm (12" x 12") Box 1
TECR1510 Parietex™ Hydrophilic 2-Dimensional Mesh, Polyester, 15 x 10 cm Box 1
TECR1515 Parietex™ Hydrophilic 2-Dimensional Mesh, Polyester, 15 x 15 cm Box 1
TET1309 Three dimensional knitted mesh- honeycomb weave rectangle (5.2" x 3.6") Box 1
TET1309D Three dimensional knitted mesh D-shaped honeycomb with slit (5.2" x 3.6") Box 1
TET1515 No hydrogel barrier. (Used for Underlay, Onlay, Inlay Ventral Hernias) Box 1
TET2020 No hydrogel barrier. (Used for Underlay, Onlay, Inlay Ventral Hernias) Box 1
TET3030 No hydrogel barrier. (Used for Underlay, Onlay, Inlay Ventral Hernias) Box 1
TET5050 Parietex™ Standard Three dimesional PY 50 x 50 CM Box 1
TET1510 Three dimesional knitted mesh (6" x 4") Box 1

ProGrip™ Self-Gripping Polyester Mesh for Prophylactic Suture-Line Reinforcement

Product Details

Mesh and fixation combined into one device, for use in incisional Hernia Prophylaxis.

Overview

Innovation That Matters

Innovation meets performance in this comprehensive line of synthetic mesh for hernia surgery. Accommodating broad flexibility in preferred techniques and in inguinal, ventral, umbilical, open and laparoscopic surgical procedures, our mesh portfolio combines superior clinical efficiency with positive patient outcomes. This depth and diversity of design allows surgeons to take a patient-specific approach to hernia repair while enjoying the enhanced value of line standardization.

Much more than a mesh

Providing the flexibility of choice

Learn More
  • †. Based on preclinical animal and/or benchtop studies.