Overview

Ventral hernia repair designed to help you1,2,([FOOTNOTE=Based on internal test report #T2294CR105, Development phase technical file. February 2016.],[ANCHOR=],[LINK=])— and your patients

Parietene™ DS composite mesh is part of our commitment to offering solutions that can help you advance patient care.

It’s made from a transparent macroporous polypropylene that’s easy to work with because it’s not too soft or too rigid.1,2

Plus, on one side, we’ve given it an absorbable synthetic film to help minimize unwanted tissue attachment.3,†

The result is a balanced mesh that’s been designed with you — and your patients — in mind.

Order Information
Order Code Description Unit of Measure Quantity
PPDS12 Parietene™ DS Composite Mesh, 12 cm round Each 1
PPDS1510 Parietene™ DS Composite Mesh, 15 x 10 cm Each 1
PPDS15 Parietene™ DS Composite Mesh, 15 cm round Each 1
PPDS2015 Parietene™ DS Composite Mesh, 20 x 15 cm Each 1
PPDS2520 Parietene™ DS Composite Mesh, 25 x 20 cm Each 1
PPDS3020 Parietene™ DS Composite Mesh, 30 x 20 cm Each 1
PPDS3530 Parietene™ DS Composite Mesh, 35 x 30 cm - not available for sale at this time. Each 1
PPDS12X3 Parietene™ DS Composite Mesh, 12 cm round, 3 pack Each 1
PPDS1510X3 Parietene™ DS Composite Mesh, 15 x 10 cm, 3 pack Each 1
PPDS15X3 Parietene™ DS Composite Mesh, 15 cm round, 3 pack Each 1
PPDS2015X3 Parietene™ DS Composite Mesh, 20 x 15 cm, 3 pack Each 1
Specifications
Device Indication Parietene™ DS composite mesh is intended for the reinforcement of abdominal wall soft tissue where a weakness exists. It is indicated for the repair of ventral hernias.
Material Composition
  • 2-D textile nonabsorbable monofilament polypropylene
  • A film composed of an absorbable synthetic polymer
  • Absorbable polycaprolactone used for  the binding agent and for the markings
  • Two prefixed sutures made from polypropylene and polyethylene
  • Pore Size([FOOTNOTE=Based on internal test report #T2294CR225, Comparison of nonabsorbable textile reinforcement properties of composite meshes. Descriptive comparison of values were obtained from benchtop testing of the textiles constitutive of the devices. Properties measured included: burst strength, resistance to plunger test, tear strength, suture pull-out strength (n=5 per group), and uniaxial breaking strength (n=6 per group). November 2016.],[ANCHOR=],[LINK=]) 2 x 2.4 mm
    Weight5 Surface density 46 g/m²
    Sterilization Ethylene oxide

    Order Information

    • †Based on preclinical studies. Results may not correlate to performance in humans.

    • ‡Please refer to the instructions for use for complete indications, contraindications, warnings, and precautions.