You just clicked a link to go to another website. If you continue, you will leave this site and go to a site run by someone else.
Medtronic Canada does not review or control the content on the other website, and is not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site not be licensed for sale in Canada.
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
By choosing to accept, you acknowledge that you are a Certified Healthcare Professional.
Renal Denervation
This is the turning point in hypertension care
Lifestyle changes and medications have defined hypertension care — until now. See how the Symplicity Spyral RDN system complements existing hypertension management protocols, review clinical evidence.
Current hypertension care strategies are not always enough to help patients achieve blood pressure control. The Symplicity Spyral RDN system is used during the Symplicity™ blood pressure procedure — the first catheter-based approach5 using radiofrequency (RF) energy that complements medications and lifestyle modifications to help reduce blood pressure.
Watch a short video to see why we’ve spent the last 10 years dedicated to developing an adjunctive solution to manage this disease.
Read on to preview:
Risk of Hypertension Animation - (00:46)
Watch this animation to see statistics about the risks of living with hypertension.
More information (see more)
Less information (see less)
The Symplicity Spyral RDN system is proven to achieve significant, safe, and sustained blood pressure reductions in the presence and absence of medications in multiple clinical trials and a real-world patient registry.1–5
*Results may vary across patients.
The Symplicity Spyral RDN system is comprised of the Symplicity Spyral multi-electrode renal denervation catheter and the Symplicity G3™ renal denervation RF generator.
Patients whose blood pressure is difficult to control may have an overactive sympathetic nervous system. The Symplicity procedure aims to suppress this inappropriately elevated sympathetic drive. The Symplicity Spyral RDN System offers a versatile, simple, and minimally invasive method to perform renal denervation.6
The procedure is performed by interventionalists due to its similarity to other procedures they perform every day.
Symplicity™ Blood Pressure Procedure Video - (04:10)
See how the Symplicity Spyral™ renal denervation system works to help lower blood pressure.
More information (see more)
Less information (see less)
Understanding which patients could benefit from the Symplicity procedure is an important step when considering this therapy.
Your patients may benefit if they:
Have uncontrolled
hypertension
Consider patients where lifestyle modifications and antihypertensive medications haven’t adequately controlled blood pressure.
Are willing to undergo
an interventional procedure
Consider patients who opt for the Symplicity procedure following shared decision-making and an attempt at lifestyle modifications and medical therapy.
The 2023 SCAI position statement recognizes renal denervation as a promising therapy for managing hypertension. Read the full statement to review recommendations for success, including patient selection, operator competency, procedural training and techniques, and organizational recommendations.
Our goal is to support you and your practice as you become familiar with this emerging therapy. We've thought through everything you'll need to activate, advance, accelerate, and optimize a Symplicity renal denervation program and successfully incorporate the procedure into your practice.
Our unwavering, long-term dedication to renal denervation has resulted in extensive clinical evidence, in-depth training and education, detailed resources to support patient care pathway development and referrals, and more. Download our brochure to learn more about how we can support you on this journey.
We want to provide you with resources that will be the most useful as you acquaint yourself with this procedure.
Our goal is to support you and your practice as you become familiar with this emerging therapy.
Böhm M, Kario K, Kandzari DE, et al. Efficacy of catheter-based renal denervation in the absence of antihypertensive medications (SPYRAL HTN-OFF MED Pivotal): a multicentre, randomised, sham-controlled trial. Lancet. 2020;395(10234):1444–1451.
Kandzari D, Townsend R, Kario K, et al. Safety and efficacy of renal denervation in patients taking antihypertensive medication. J Am Coll Cardiol. 2023;82(19):1809–1823.
Mahfoud F, Kandzari DE, Kario K, et al. Long-term efficacy and safety of renal denervation in the presence of antihypertensive drugs (SPYRAL HTN-ON MED): a randomised, sham-controlled trial. Lancet. 2022;399(10234):1401–1410.
Mahfound F, Mancia G, Schmieder R, et al. Outcomes following radiofrequency renal denervation according to antihypertensive medications: subgroup analysis of the Global SYMPLICITY Registry DEFINE. EuroPCR 2023.
Medtronic data on file. Global Symplicity Registry clinical data snap, March 2023.
Medtronic Symplicity Spyral multi-electrode renal denervation catheter instructions for use.