Healthcare Professionals
Mirro MRI
Implantable Cardioverter Defibrillators (ICDs) for Tachyarrhythmia Management
You just clicked a link to go to another website. If you continue, you will leave this site and go to a site run by someone else.
Medtronic Canada does not review or control the content on the other website, and is not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site not be licensed for sale in Canada.
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
By choosing to accept, you acknowledge that you are a Certified Healthcare Professional.
Healthcare Professionals
Implantable Cardioverter Defibrillators (ICDs) for Tachyarrhythmia Management
Mirro MRI™ ICD is approved for use in the MR environment, when MR conditions for use are met. MRI SureScan™ devices have simple scanning conditions, including:
Lead Integrity Alert
Lead Integrity Alert (LIA) is designed to provide advance warning for lead fracture and reduce the patient’s risk of inappropriate shocks.
72% of patients monitored by LIA either did not receive an inappropriate shock or had at least a 3-day warning before being shocked, compared to 50% of patients monitored by lead impedance only.1
In addition, LIA detected more lead issues than lead impedance monitoring alone with St. Jude Medical Riata™* and Durata®* leads, and Boston Scientific Endotak leads.2
Longer Nominal VF NID*
ADVANCE III found that the use of a longer NID (VF NID = 30/40) yielded a 39% reduction in appropriate but unnecessary therapies compared to a shorter detection interval (VF NID = 18/24).3
ATP During Charging™, in addition to VF NID = 30/40, resulted in another 52% reduction in unnecessary shocks.3
Mirro MRI ICD combines our exclusive ATP Before and During Charging with a long detection interval to minimize shocks.4
*Number of intervals to detect
20% increased longevity compared to Protecta™ ICD with a new battery, new capacitors, and enhanced circuit efficiencies.4-7
Device | Model Number(s) |
---|---|
Mirro MRI Single Chamber |
|
Mirro MRI Dual Chamber |
|
Medtronic and the Medtronic logo are trademarks of Medtronic. ™Third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
Swerdlow CD, Gunderson B, Ousdigian K, Sachanandani H, Ellenbogen K. HRS Conference 2010.
Ellenbogen KA, Gunderson BD, Stromberg KD, Swerdlow CD. Performance of Lead Integrity Alert to assist in the clinical diagnosis of implantable cardioverter defibrillator lead failures: analysis of different implantable cardioverter defibrillator leads. Circ Arrhythm Electrophysiol. December 2013;6(6):1169-1177.
Arenal A, Proclemer A, Kloppe A, et al. Different impact of long-detection interval and anti-tachycardia pacing in reducing unnecessary shocks: data from the ADVANCE III trial. Europace. November 2016;18(11):1719-1725.
Mirro MRI DR SureScan DDME3D4 Device Manual. http://manuals.medtronic.com/manuals/main/region
Protecta XT DR D354DRM Clinician Manual. http://manuals.medtronic.com/manuals/main/region
Protecta XT VR D354VRM Clinician Manual. http://manuals.medtronic.com/manuals/main/region
Mirro MRI VR SureScan DVME3D4 Device Manual. http://manuals.medtronic.com/manuals/main/region