The content of this website is exclusively reserved for Healthcare Professionals in countries with applicable health authority product registrations, except those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011, article 34.
Click “OK” to confirm you are a Healthcare Professional.
Echelon™ microcatheter solutions for aneurysm treatment features a strong nitinol design for confident and stable delivery of coils when minimal paint-brushing effect is desired.
Designed to perform at every turn from navigation to Axium™ aneurysm treatment.
Echelon™ microcatheter’s strong nitinol braid technology with progressive picks-per-inch, provides.1,2
The Echelon™ microcatheter is intended to access peripheral and neuro vasculature for the controlled selective infusion of physician-specified therapeutic agents such as embolization materials and of diagnostic materials such as contrast media.
See the device manualCFN | Product Name | Proximal Outer Diameter (F) | Distal Outer Diameter (F) | Distal Inner Diameter (in) | Total Length (cm) | Usable Length (cm) | Tip Length (mm) | Tip Shape |
---|---|---|---|---|---|---|---|---|
105-5091-150 |
Echelon™ 10 |
2.1 |
1.7 |
0.017 |
155 |
150 |
- |
Straight |
145-5091-150 |
Echelon™ 10 |
2.1 |
1.7 |
0.017 |
155 |
150 |
2.5 |
45° |
190-5091-150 |
Echelon™ 10 |
2.1 |
1.7 |
0.017 |
155 |
150 |
5 |
90° |
105-5092-150 |
Echelon™ 14 |
2.4 |
1.9 |
0.017 |
155 |
150 |
- |
Straight |
145-5092-150 |
Echelon™ 14 |
2.4 |
1.9 |
0.017 |
155 |
150 |
2.5 |
45° |
190-5092-150 |
Echelon™ 14 |
2.4 |
1.9 |
0.017 |
155 |
150 |
5 |
90° |
Do you need support for procedures? Or information on our products and solutions?
Our team is happy to help answer any questions you may have.
CONTACT USDWGS105-5092-150
DWGS105-5091-150
TR03-044
TR02-134A
DWGS105-5091-150. Echelon™ 10 catheter only
See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative and/or consult the Medtronic website at medtronic.uk