Your browser is out of date

With an updated browser, you will have a better Medtronic website experience. Update my browser now.

×

Skip to main content

Healthcare Professionals

Fully Integrated CRT Implant System

Delivery Systems

  

Expand All

SUREVALVE

SureValve™ Integrated Valve

SureValve Integrated Valve

Attain Command® + SureValve™ & Attain Select™ II + SureValve™

Delivery Catheter System for Coronary Sinus Cannulation & Delivery Catheter System for Sub-Selection

The SureValve™ Integrated Valve is designed to simplify CRT implantation1-5 by reducing procedural steps1 and enhancing hemostasis performance.2

Two CRT delivery systems are available with SureValve:


Important Safety Information

Surgical complications, such as cardiac perforation, may occur and care must be taken when placing and positioning a cardiac lead.


SureValve features include:

  • Fewer tubes and less bulk, compared to catheters with nonintegrated valves3

Detail

 

  • Guide rails that enable easier slitting2 and less buckling

Detail

 

  • A unique valve tool that enables one-handed injection, aides in guide wire insertion, and facilitates flushing and aspiration6

Detail

 

  • Compatibility with a wide range of guide wire and LV lead sizes6,7

          Attain Command + SureValve Systems are compatible with:

  • Leads diameter: 2.1 mm (6.2 Fr, 0.081 in) maximum
  • Other transvenous devices diameter: 2.4 mm (7.1 Fr, 0.093 in) maximum

          Attain Select II + SureValve Systems are compatible with:

  • Leads body outer diameter: 1.77 mm (5.3 Fr, 0.070 in) maximum
  • Other transvenous devices outer diameter: 1.85 mm (5.5 Fr, 0.072 in) maximum and 0.89 mm (2.7 Fr, 0.035 in) Straight Blue Inner Catheter

References

1

Dahlberg L. Procedural steps comparison when using Attain catheters with SureValve, Medtronic adjustable valve, and pressure products SafeSheath valve. Medtronic data on file, October 2012.

2

Dahlberg L. Physician evaluation of procedure steps when using Attain catheters with SureValve. Medtronic data on file, October 2012.

3

Drake R. The SureValve System reduces builk. Medtronic data on file, November 2012.

4

Drake R. Attain Select II catheter length analysis. Medtronic data on file, November 2012.

5

Drake R. The SureValve System is shorter, which reduces the required lead length by 6 cm. Medtronic data on file, November 2012.

6

Medtronic Attain Command + SureVave Guide Catheter for Left-Heart Delivery System Manual.

7

Medtronic Attain Select II + SureValve Delivery Catheter System Manual.

COMMAND

SELECT II

CLARITY VENOGRAM BALLOON

ADVANCED TOOLS

DEFLECTABLE

Hybrid Guide Wire