TourGuide Steerable Sheath

EVAR and TEVAR Procedures

Overview

Precisely guide your next intervention with the TourGuide™ steerable sheath. The sheath can deflect up to 180° to facilitate the delivery of diagnostic and therapeutic devices to a wide variety of vessel takeoffs and challenging anatomical areas.*

The TourGuide steerable sheath is available for sale in the United States and Europe.

INDICATIONS  

See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative and/or consult the Medtronic Europe website.

The steerable sheath, model TourGuide is intended for the introduction of diagnostic and therapeutic devices into the human vasculature, including but not limited to intracardiac, renal, or other peripheral placements. Do not use this device for neural placements.

Product Details

The TourGuide steerable sheath provides quick access to indicated anatomy. By minimizing multiple exchanges associated with different catheter selections, the sheath may reduce overall procedure time.

Advanced Catheter Technology

  • Provides the strength and conformability needed for delivering various interventional devices

Curve Retention

  • Maintains desired deflection angle, providing a stable platform for delivering devices to their desired destination

180° Tip Deflection

  • Physician-directed to deliver diagnostic and therapeutic devices to a wide variety of vessel take offs and difficult anatomic areas1

THREE WORKING LENGTHS (45, 55, AND 90 CM)

  • Designed to access indicated areas to perform interventions

 

TourGuide Steerable Sheath Design
Features of the TourGuide steerable sheath include:

  1. Radiopaque distal marker
  2. Tapered distal tip
  3. Hydrophobic coated sheath
  4. Braided shaft
  5. Rotating collar
  6. Tip position indicator
  7. Hemostatic valve
TourGuide Steerable Sheath Design

Manuals and Technical Guides

Instructions for Use
Find this technical manual in the product labeling supplied with each device.

MODEL SPECIFICATIONS

Ordering Information

Model Number Inner
Diameter
Size
(F)
Usable
Length 
(cm)
Deflection
Length
@ 180°
(mm)
TG0654509 6.5 45 
TG0654517 6.5 45 17
TG0655509 6.5 55 9
TG0655517 6.5 55 17
TG0659009 6.5 90 9
TG0704509 7.0 45 9
TG0704517 7.0 45 17
TG0705509 7.0 55 9
TG0705517 7.0 55 17
TG0709009    7.0 90 9
TG0854517 8.5 45 17
TG0854522 8.5 45 22
TG0855517 8.5 55 17
TG0855522 8.5 55 22
TG0859017    8.5 90 17
*

Bench test data on file at Medtronic. Test data not indicative of clinical performance.

Lock feature inherent in design to hold curve while delivering devices.

1

OSCOR SEG Characterization Study; Joshua D Adams, MD, and Claudio J Schonholz, MD. Variable Curve Directable Guide Sheath from Aptus to Facilitate Other Challenging Endovascular Procedures. Session 47, NEW TECHNIQUES, TECHNOLOGY AND CONCEPTS