Uw webbrowser is verouderd

Met een bijgewerkte browser heeft u een betere ervaring met de website van Medtronic. Werk mijn browser nu bij.

×

Skip to main content

Healthcare Professionals

Reliant Stent Graft Balloon Catheter

EVAR and TEVAR Procedures

Overview

Expand possibilities with the Reliant™ stent graft balloon catheter: the versatile, reliable, and conformable solution you need for stent graft procedures and temporary occlusion of the aorta and large vessels.

INDICATIONS  

See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative and/or consult the Medtronic Europe website.

The Reliant stent graft balloon catheter is intended to temporarily occlude large vessels or to expand vascular prostheses. The device is intended to assist in the expansion of self-expanding stent grafts.

Product Details

Versatile Design

  • One low-profile balloon that's able to treat thoracic, abdominal, and iliac anatomies with a wide range of inflation diameters (10 mm–46 mm)
  • Compatible with the 12 F Sentrant™ introducer sheath*

Reliable Performance

  • Consistent inflation and deflation time
  • Stable expansion with minimum balloon overhang to reduce risk of vessel trauma
  • Dependable expansion even after multiple inflations and deflations*

Improves Stent Graft Conformability

  • Expands kinks and smooths creases from the graft material
  • Compliant balloon expansion

Clinical Uses

 

Reliant Stent Graft Balloon Catheter Features

The Reliant stent graft balloon provides multiple treatments in a single balloon for thoracic, abdominal, and iliac stent graft procedures.

  1. Compatible with the 12 F Sentrant introducer sheath
  2. Material: compliant polyurethane (non-latex)
  3. Inflation diameter: 10–46 mm
  4. Shaft size: 8 F
  5. Working length: 100 cm
  6. Guidewire diameter: 0.038"/0.9652 mm or smaller
Reliant Stent Graft Balloon Catheter Features

BALLOON INFLATION (46 MM BALLOON)

Diameter
(mm)
ml
(cc)
10 3
20 9
30 19
40 41
46* 60

* Maximum inflation diameter

CAUTION: This table is only a guide. Balloon expansion should be carefully monitored under fluoroscopy. Do not exceed maximum inflation diameter (46 mm). Overinflation can cause damage to the vessel wall or stent graft or lead to rupture.

Manuals and Technical Guides

Instructions for Use
Find this technical manual in the Medtronic Manual Library or in the product labeling supplied with each device.

MODEL SPECIFICATIONS

Ordering Information

Product
Code
Inflation
Diameter
(mm)
Shaft Size
(F)
Working
Length
(cm)
Sheath
Compatibility
(F)
AB46 10-46 8 100 12
*

Data on file Medtronic. Maximum of 20 inflations, deflations.