Uw webbrowser is verouderd

Met een bijgewerkte browser heeft u een betere ervaring met de website van Medtronic. Werk mijn browser nu bij.

×

Er wordt nu een video gestart - gelukkig gezin

LITERATUUR

Expand All

STARTPAGINA

  • 1 Barczynski M, Konturek A, Cicho+ä S. Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy. Br J Surg 2009;96(3):240-246.
  • 2 Barczynski M, Konturek A, Stopa M, Honowska A, Nowak W. Randomized Controlled Trial of Visualization versus Neuromonitoring of the External Branch of the Superior Laryngeal Nerve during Thyroidectomy. World Journal of Surgery 2012;36(6):1340-1347.
  • 3 Lifante JC, McGill J, Murry T, Aviv JE, Inabnet WB. A prospective, randomized trial of nerve monitoring of the external branch of the superior laryngeal nerve during thyroidectomy under local/regional anesthesia and IV sedation. Surgery (USA) 2009;146(6):1167-1173.
  • 4 Dionigi G, Boni L, Rovera F, et al. Neuromonitoring and video-assisted thyroidectomy: a prospective, randomized case-control evaluation. Surg Endosc 2009;23(5):996-1003.
  • 5 Snyder SK, Lairmore TC, Hendricks JC, Roberts JW. Elucidating Mechanisms of Recurrent Laryngeal Nerve Injury During Thyroidectomy and Parathyroidectomy. J Am Coll Surg 2008;206(1):123-130.
  • 6 Gao EL, Zou X, Zhou YH, Xie DH, Lan J, Guan HG. Increased prediction of right nonrecurrent laryngeal nerve in thyroid surgery using preoperative computed tomography with intraoperative neuromonitoring identification. World J Surg Oncol 2014;12(1):1-6.
  • 7 Hermann M. Main topics: Neuromonitoring in thyroid surgery - Who benefits? Eur Surg 2003;35(5):225-226.
  • 8 Brauckhoff M, MacHens A, Sekulla C, Lorenz K, Dralle H. Latencies shorter than 3.5 ms after vagus nerve stimulation signify a nonrecurrent inferior laryngeal nerve before dissection. Ann Surg 2011;253(6):1172-1177.
  • 9 Chiang FY, Lu IC, Tsai CJ, Hsiao PJ, Lee KW, Wu CW. Detecting and identifying nonrecurrent laryngeal nerve with the application of intraoperative neuromonitoring during thyroid and parathyroid operation. Am J Otolaryngol Head Neck Med Surg 2012;33(1):1-5.
  • 10 Schneider R, Randolph GW, Sekulla C et al. Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury. Head & Neck 2013;35(11):1591-1598.
  • 11 Phelan E, Schneider R, Lorenz K et al. Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: A prospective, multicenter study. Laryngoscope 2014;124(6):1498-1505.
  • 12 Snyder SK, Sigmond BR, Lairmore TC, Govednik-Horny CM, Janicek AK, Jupiter DC. The long-term impact of routine intraoperative nerve monitoring during thyroid and parathyroid surgery. Surgery (United States) 2013;154(4):704-713.
  • 13 Angelos P. Recurrent Laryngeal Nerve Monitoring: State of the Art, Ethical and Legal Issues. Surg Clin North Am 2009;89(5):1157-1169.
  • 14 Melin M, Schwarz K, Lammers B, Goretzki P. IONM-guided goiter surgery leading to two-stage thyroidectomy-indication and results. Langenbeck’s Archives of Surgery 2013;398(3):411-418.
  • 15 Dionigi G, Barczynski M, Chiang FY et al. Why monitor the recurrent laryngeal nerve in thyroid surgery? J Endocrinol Invest 2010;33(11):819-822.
  • 16 Dionigi G, Bacuzzi A, Boni L, et al. What is the learning curve for intraoperative neuromonitoring in thyroid surgery? Int J Surg 2008;6(Suppl. 1):S7-S12.
  • 17 Duclos A, Lifante JC, Ducarroz S, Soardo P, Colin C, Peix JL. Influence of Intraoperative Neuromonitoring on Surgeons Technique During Thyroidectomy. World Journal of Surgery 2011;35(4):773-778.
  • 18 Wojtczak B, Sutkowski K, Kaliszewski K, Glod M, Barczynski M. Experience with intraoperative neuromonitoring of the recurrent laryngeal nerve improves surgical skills and outcomes of non-monitored thyroidectomy. Langenbeck’s Arch Surg 2016;402(4):709-717-9.
  • 19 Schneider R, Sekulla C, MacHens A, Lorenz K, Nguyen Thanh P, Dralle H. Postoperative vocal fold palsy in patients undergoing thyroid surgery with continuous or intermittent nerve monitoring. Br J Surg 2015;102(11):1380-1387.
  • 20 Thomusch O, Sekulla C, Timmermann W et al. Intraoperative Neuromonitoring in Thyroid Surgery. European Surgery 2003;35(5):240-245.
  • 21 Thomusch O, Sekulla C, Walls G, MacHens A, Dralle H. Intraoperative neuromonitoring of surgery for benign goiter. Am J Surg 2002;183(6):673-678.
  • 22 Kim SJ, Lee KE, Kwon MR et al. Intraoperative neuromonitoring of the external branch of the superior laryngeal nerve during robotic thyroid surgery. Int J Med Rob Comput Assisted Surg 2011;7(Supp 2):43.
  • 23 Khaled AO, Irfan M, Baharudin A, Shahid H. Comparing the morbidity of external laryngeal nerve injury in thyroid surgery with and without identifying the nerve using intraoperative neuromonitoring. Med J Malaysia 2012;67(3):289-292.
  • 24 Schneider R, Lorenz K, Sekulla C, Thanh PN, MacHens A, Dralle H. Validity of continuous versus intermittent intraoperative neuromonitoring for prediction of early postoperative and permanent recurrent laryngeal nerve palsy after thyroidectomy. 2013. Report No.: 398.
  • 25 Sughrue ME, Yang I, Rutkowski MJ, Aranda D, Parsa AT. Preservation of facial nerve function after resection of vestibular schwannoma. Br J Neurosurg 2010;24(6):666-671.
  • 26 Liu H, Wen W, Huang H et al. Recurrent pleomorphic adenoma of the parotid gland: Intraoperative facial nerve monitoring during parotidectomy. Otolaryngology - Head and Neck Surgery (United States) 2014;151(1):87-91.
  • 27 Terrell JE KPY. Clinical outcome of continuous facial nerve monitoring during primary parotidectomy. Archives of OtolaryngologyGÇöHead & Neck Surgery 1997;123(10):1081-1087.
  • 28 Snyder SK, Hendricks JC. Intraoperative neurophysiology testing of the recurrent laryngeal nerve: Plaudits and pitfalls. Surgery (USA) 2005;138(6):1183- 1192.
  • 29 Eisele DW. Intraoperative Electrophysiologic Monitoring of the Recurrent Laryngeal Nerve. The Laryngoscope 1996;106(4):443-449.
  • 30 Petro ML SJPA. Transcricothyroid, intraoperative monitoring of the vagus nerve. Archives of Otolaryngology Head & Neck Surgery 2006;132(6):624-628.
  • 31 Thomusch O, Sekulla C, Machens A, Neumann HJ, Timmermann W, Dralle H. Validity of intra-operative neuromonitoring signals in thyroid surgery. Langenbeck’s Arch Surg 2004;389(6):499-503.
  • 32 Ulmer C, Friedrich C, Kohler A et al. Impact of continuous intraoperative neuromonitoring on autonomic nervous system during thyroid surgery. Head Neck 2011;33(7):976-984.
  • 33 Friedrich C, Ulmer C, Rieber F et al. Safety analysis of vagal nerve stimulation for continuous nerve monitoring during thyroid surgery. Laryngoscope 2012;122(9):1979-1987.

FEITEN OVER RISICO'S VAN HOOFD-HALSCHIRURGIE

CONTINUE NEUROMONITORING

BEWIJS VAN KLINISCHE WAARDE

Raadpleeg de handleiding van het apparaat voor meer informatie over de gebruiksaanwijzing, indicaties, contra-indicaties, waarschuwingen, voorzorgsmaatregelen en mogelijke bijwerkingen. Neem voor nadere informatie contact op met Medtronic en/of raadpleeg de website van Medtronic op www.medtronic.com