Il tuo browser è obsoleto

Con un browser aggiornato, l'esperienza di navigazione sul sito Web di Medtronic sarà migliore. Aggiorna il mio browser adesso.

×

Skip to main content

BALLOONS AND INFLATION DEVICES Balloon Kyphoplasty

PRODUCT DETAILS

These balloons and inflation devices are available to assist in fracture reduction.

Inflatable Bone Tamps

Kyphon™ inflatable bone tamps (IBT), or orthopaedic balloons, are available for use with 8 and 10ga introducers in three lengths — 10mm, 15mm, and 20mm — to address differing vertebral anatomy.

Kyphon Express II IBT

Size 2, 10ga, 700 psi maximum pressure rating

1mm IBT (KE102)
10 mm IBT (KE102)

20 mm IBT (KE202)
20 mm IBT (KE202)

15 mm IBT (KE152)
15 mm IBT (KE152)

Kyphon Express II Inflatable Bone Tamp

IBT Size Initial Length (mm) Max Volume
(cc)
Pressure
(psi)

10/2

10

3

700

15/2

15

4

700

20/2

20

5

700

Kyphon Xpander II IBT

Size 3, 8ga, 700 psi maximum pressure rating

110 mm IBT (KX103)
10 mm IBT (KX103)

20 mm IBT (KX203)
20 mm IBT (KX203)

15 mm IBT (KX153)
15 mm IBT (KX153)

Kyphon Xpander II Inflatable Bone Tamp

IBT Size Initial Length (mm) Max Volume
(cc)
Pressure
(psi)

10/3

10

4

700

15/3

15

5

700

20/3

20

6

700

Kyphon Express IBT

Size 2, 10ga, 400 psi maximum pressure rating

10mm IBT (K15A)
10 mm IBT (K15A)

15 mm IBT (K15B)
15 mm IBT (K15B)

Kyphon Express Inflatable Bone Tamp

IBT Size Initial Length (mm) Max Volume
(cc)
Pressure
(psi)

10/2

10

4

400

15/2

15

5

400

Kyphon XPANDER IBT

Size 3, 8ga, 400 psi maximum pressure rating

10mm IBT (K13A)
10 mm IBT (K13A)

20 mm – K08A)
20 mm – K08A

15 mm IBT (K09A)
15 mm IBT (K09A)

Kyphon Xpander Inflatable Bone Tamp

IBT Size Initial Length (mm) Max Volume
(cc)
Pressure
(psi)

10/3

10

4

400

15/3

15

4

400

20/3

20

6

400

Kyphon Exact IBT Directional IBT

Size 3, 8ga, 300 psi maximum pressure rating

10 mm IBT (K17A)
10 mm IBT (K17A)

15 mm IBT (K17B)
15 mm IBT (K17B)

Kyphon Exact Inflatable Bone Tamp

IBT Size Initial Length (mm) Max Volume
(cc)
Pressure
(psi)

10/3

10

3

300

15/3

15

4

300

Inflation Syringes

These syringes are used to inflate IBTs to reduce fractures and create a void in the vertebral body during balloon kyphoplasty procedures.

Kyphon Inflation Syringe

This syringe is compatible with all Kyphon™ IBTs.

Inflation Syringe (A08E)
Inflation Syringe (A08E)

Kyphon Xpander Inflation Syringe

This syringe is not compatible with the Kyphon™ Xpander II or Express II 700 psi-rated IBTs.

Inflation Syringe (A08A)