Il tuo browser è obsoleto

Con un browser aggiornato, l'esperienza di navigazione sul sito Web di Medtronic sarà migliore. Aggiorna il mio browser adesso.

×

Skip to main content

Professionisti del settore sanitario

ACT Plus

Automated Coagulation Timer System

ACT Plus Automated Coagulation Timer System

Precise, Reliable – The Trusted Standard

Blood Diagnostics and Clot Detection

In addition to running cardiopulmonary bypass, we know that you rely on accurate blood diagnostic results.

The ACT Plus® System combines a trusted standard in precise clot detection technology with state-of-the-art user features including data management and connectivity-ready capabilities. It is a microprocessor-controlled electromechanical coagulation instrument designed to determine coagulation endpoints in fresh and citrated whole blood samples. Clotting-time results are presented on the instrument’s Clot Time Display (CTD) and Liquid Crystal Display (LCD) screens.

The ACT Plus System provides long-term data storage and retrieval, with access to previous patient and quality control test data. Test results are stored in the order in which they are performed. The ability to externally transfer or save data enhances the system’s versatility.

The ACT Plus System is portable and well suited for all point-of-care testing situations. It offers the reliability required in:

  • Cardiovascular and vascular surgery
  • ECMO
  • Cardiac catheterization laboratories
  • Critical care units
  • Hemodialysis units

Manage Your ACT Plus System Data Efficiently and Effectively

As part of our ongoing commitment to helping you manage your work efficiently and effectively, we offer the ACT Plus EDM external data manager to accompany the ACT Plus Automated Coagulation Timer System.

By combining this powerful software with the ACT Plus System, you will have access to the reports you'll need to analyze test results and make informed decisions. This timesaving data management solution offers added convenience, reassurance and confidence—allowing you to stay focused on improving patient outcomes.

The ACT Plus EDM is a versatile Microsoft Access-based data management software application that runs on a PC and is designed to help you manage your patient, QC, instrument and user ID data. All aspects of Microsoft Access software required to run the application are included with the ACT Plus EDM.

Ordering Info

ACT Plus® Automated Coagulation Timer

ACT Plus Instrument

Order Number

Description

# of Units

ACT100

ACT Plus System is a microprocessor-controlled electromechanical coagulation instrument for determination of activated coagulation times

1 per box

ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges

402-01

Low Range Activated Clotting Time (LR ACT) - Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis

50 per box

402-02

Recalcified Activated Clotting Time (RACT) - For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL

50 per box

402-03

High Range Activated Clotting Time (HR ACT) - Fresh whole blood test for CV surgery, PTCA, or vascular surgery

50 per box

402-07

Heparinase Test Cartridge (HTC) - Fresh whole blood test used to identify the presence of heparin in the patient's blood sample

20 per box

 

 

Each box contains vials of lyophilized control and 15 vials of deionized water

ACT® CLOTtrac® Coagulation Controls

550-01

CLOTtrac CWB Coagulation Control - Verify performance of 402-01 and 402-02 cartridges, and the ACT Plus Instrument (when performing QC on the LR ACT cartridge (#402-01), calcium chloride (#550-11) must be added with the CLOTtrac CWB coagulation control)

15 per box

550-07

CLOTtrac HR Coagulation Control - Verify performance of 402-03, and 402-07 cartridges and the ACT Plus Instrument

15 per box

550-08

CLOTtrac HR Abnormal Coagulation Control - Verify performance of 402-03 cartridges and the ACT Plus Instrument

15 per box

550-09

CLOTtrac LR Abnormal Coagulation Control - Verify performance of 402-01 cartridges and the ACT Plus® Instrument (when performing QC on the LR ACT cartridge (#402-01), calcium chloride (#550-11) must be added with the CLOTtrac LR abnormal coagulation control)

15 per box

550-10

CLOTtrac RACT Abnormal Coagulation Control - Verify performance of 402-02 cartridges and the ACT Plus® Instrument

15 per box

550-12

CLOTtrac HTC Coagulation Control - Verify performance of 402-07 cartridges and the ACT Plus® Instrument

15 per box

550-13

CLOTtrac HR Control Pack - Verify performance of 402-03 cartridges and the ACT Plus Instrument (contains 15 HR Normal and 15 HR Abnormal)

15 per box

550-11

Calcium Chloride 5 ml vial - Use with control nos. 550-01, 550-09 in cartridge 402-01

15 per box

ACT Accessories

ACTSC

ACT Plus® Bar Code Scanner

1 per box

ACTFILHR

High Range ACT Easy Fill Accessory

100 per box

ACTFILLR

Low Range ACT Easy Fill Accessory

100 per box

300-02

Blunt needles, 1-7/16", 19 GA

100 per box

31363

ACTtrac® Electronic Control for ACT Plus

1 per box

303-58

Actuator Cleaning Kit

1 per box

313-11

Temperature Verification Cartridge for ACT Plus®

1 per box

313-50

HEPline Kit

1 per box

ACTEDM

ACT External Data Manager Software

1 per box