You just clicked a link to go to another website. If you continue, you will leave this site and go to a site run by someone else.
Medtronic does not review or control the content on the other website, and we are not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site are not approved in the Indian Subcontinent.
Any and all information provided is intended for general overview. Viewers taking any decision based on the information provided herein are requested to seek professional advice.
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
The content of this website is exclusively reserved for Healthcare Professionals in countries with applicable health authority product registrations.
Click “OK” to confirm you are a Healthcare Professional.
Find out how bone grafting surgeries can help people find relief. These personal stories can help you learn about what it’s like to have surgery using bone graft, but keep in mind that all treatment results are specific to the individual patient, and results may vary.
Also on this page are videos of patients who have received donor tissue for spinal fusion. Watch their stories and learn what a difference donated tissue can make in the life of a patient.
BRIEF SUMMARY OF INDICATIONS, CONTRAINDICATIONS, AND WARNINGS FOR:
Infuse™ Bone Graft/LT-Cage™ Lumbar Tapered Fusion Device
Infuse™ Bone Graft/Inter Fix™ Threaded Fusion Device
Infuse™ Bone Graft/Inter Fix™ RP Threaded Fusion Device
Infuse™ Bone Graft/Perimeter™ Interbody Fusion Device
Infuse™ Bone Graft/Clydesdale™ Spinal System
Infuse™ Bone Graft/Divergence-L™ Anterior/Oblique Lumbar Fusion System
Infuse™ Bone Graft/Pivox™ Oblique Lateral Spinal System
The Infuse™ Bone Graft/Medtronic Interbody Fusion Device is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) at one level from L2-S1, who may also have up to Grade I spondylolisthesis or Grade 1 retrolisthesis at the involved level.
The following interbody devices and surgical approaches may be used with Infuse™ Bone Graft:
The Infuse™ Bone Graft/Medtronic Interbody Fusion Device consists of two components containing three parts – a spinal fusion cage, a recombinant human bone morphogenetic protein, and a carrier/scaffold for the bone morphogenetic protein and resulting bone. These components must be used as a system for the prescribed indication described above. The bone morphogenetic protein solution component must not be used without the carrier/scaffold component or with a carrier/scaffold component different from the one described in this document. The Infuse™ Bone Graft component must not be used without the Medtronic Interbody Fusion Device component.
NOTE: The Inter Fix™ Threaded Fusion Device and the Inter Fix™ RP Threaded Fusion Device may be used together to treat a spinal level. The LT-Cage™ Lumbar Tapered Fusion Device, the Perimeter™ Interbody Fusion Device, the Clydesdale™ Spinal System, the Divergence-L™ Anterior/Oblique Lumbar Fusion System, and the Pivox™ Oblique Lateral Spinal System implants are not to be used in conjunction with either the Inter Fix™ OR Inter Fix™ RP implants to treat a spinal level.
The Infuse™ Bone Graft/Medtronic Interbody Fusion Device is contraindicated for patients with a known hypersensitivity to recombinant human Bone Morphogenetic Protein-2, bovine Type I collagen, or to other components of the formulation and should not be used in the vicinity of a resected or extant tumor, in patients with any active malignancy, or patients undergoing treatment for a malignancy; in patients who are skeletally immature; in pregnant women; or in patients with an active infection at the operative site or with an allergy to titanium, titanium alloy, or polyetheretherketone (PEEK).
There are no adequate and well-controlled studies in human pregnant women. In an experimental rabbit study, rhBMP-2 has been shown to elicit antibodies that are capable of crossing the placenta. Women of child bearing potential should be warned by their surgeon of potential risk to a fetus and informed of other possible orthopedic treatments. The safety and effectiveness of this device has not been established in nursing mothers. Women of child- bearing potential should be advised to not become pregnant for one year following treatment with this device.
Please see the Infuse™ Bone Graft package insert for the complete list of indications, warnings, precautions, adverse events, clinical results, definition of DDD, and other important medical information. The package insert also matches the sizes of those sized devices that are indicated for use with the appropriate Infuse™ Bone Graft kit. An electronic version of the package insert may be found at www.medtronic.com/manuals.
CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician with appropriate training or experience.
BRIEF SUMMARY OF INDICATIONS, CONTRAINDICATIONS, AND WARNINGS FOR:
INFUSE™ BONE GRAFT
Infuse Bone Graft is indicated for treating acute, open tibial shaft fractures that have been stabilized with IM nail fixation after appropriate wound management. Infuse Bone Graft must be applied within 14 days after the initial fracture. Prospective patients should be skeletally mature.
Infuse Bone Graft consists of two components – recombinant human Bone Morphogenetic Protein-2 solution and a carrier/scaffold for the bone morphogenetic protein solution and resulting bone. These components must be used as a system. The bone morphogenetic protein solution component must not be used without the carrier/scaffold component or with a carrier/scaffold component different from the one described in this document.
Infuse Bone Graft is contraindicated for patients with a known hypersensitivity to recombinant human Bone Morphogenetic Protein-2, bovine Type I collagen or to other components of the formulation and should not be used in the vicinity of a resected or extant tumor, in patients with an active malignancy or patients undergoing treatment for a malignancy. Infuse Bone Graft should also not be used in patients who are skeletally immature, in patients with an inadequate neurovascular status, in patients with compartment syndrome of the affected limb, in pregnant women, or in patients with an active infection at the operative site.
There are no adequate and well controlled studies in human pregnant women. In an experimental rabbit study, rhBMP-2 has been shown to elicit antibodies that are capable of crossing the placenta. Women of child bearing potential should be warned by their surgeon of potential risk to a fetus and informed of other possible orthopedic treatments. The safety and effectiveness of this device has not been established in nursing mothers. Women of child-bearing potential should be advised to not become pregnant for one year following treatment with this device.
Please see the package insert for the complete list of indications, warnings, precautions, adverse events, clinical results, and other important medical information.
CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician with appropriate training or experience.