Overview

Detect Hypoxic Events Up to 90 Seconds Earlier for Critically Ill Patients1

The Nellcor™ SpO2 forehead sensor detects hypoxic events 90 seconds faster.([FOOTNOTE=Bebout DE, Mannheimer PD, Wun C-C. Site-dependent differences in the time to detect changes in saturation during low perfusion. Crit Care Med. 2001;29(12)A115.],[ANCHOR=View Abstract],[LINK=content/mitg/websites/languagemasters/emea/en-gb/support/clinical-evidence.html?id=805201]),([FOOTNOTE=A technology overview of the Nellcor™ OxiMax™ pulse oximetry system. Internal testing.],[ANCHOR=],[LINK=]),([FOOTNOTE=MacLeod DB, Cortinez LI, Keifer JC, et al. The desaturation response time of finger pulse oximeters during mild hypothermia. Anaesthesia. 2005;60(1):65-71.],[ANCHOR=View Abstract],[LINK=content/mitg/websites/languagemasters/emea/en-gb/support/clinical-evidence.html?id=569656])

When a patient is in respiratory distress and SpO2 is lower than 80%, accurate real-time information is crucial for the right clinical decisions. The unique Expanded Accuracy LoSat™ Accuracy Range 60% to 100% empowers patient management in challenging situations.([FOOTNOTE=FDA 510(k).],[ANCHOR=],[LINK=])

Product Features

The Nellcor™ SpO2 forehead sensor offers:

  • Easy plug-and-play use
  • Up to 90 seconds faster reaction to critical events1
  • LoSat accuracy
  • A wide sensor range

How to Order

For additional information or to place an order, call Customer Service at +44 (0) 19 2320 2504.

Order Information
Order Code Description Unit of Measure Quantity
MAXFAST Nellcor™ SpO2 Forehead Sensor Case 24
Physical
Dimensions 99.6 x 36 x 102.5 mm (3.9 x 1.4 x 4.0 in.)
Weight 210 g (8.2 oz)
Safety
Complies with IEC 60601-1, IEC 60601-1-2, CSA C22.2#601.1-M90AMD2, ISO 9919, IEC 80601-2
Type CF applied part, defibrillator proof
SpO2 sensors
Wavelength range 500 to 1,000 nm
Emitted light energy ≤ 15m W
Environmental
Module
Operating temperature 0 to 45oC (32 to 113oF)
Storage temperature -40 to 70oC (-40 to 158oF)
Operating humidity 95% RH max. at 40oC (104oF)
Storage humidity 95% RH max. at 65oC (150oF)
Operating altitude Up to 4,600 m (15,000 ft)
Storage altitude Up to 15,300 m (50,000 ft)

Philips M1943NL is required to use the Nellcor™ SpO2 module.

Single-patient use and specialty sensor accuracy1-3(adult - neonate)
Saturation (%SpO2 ± 1 SD):  
70% to 100% ± 2 digits  
60% to 80% ± 3 digits  
Low perfusion 70% to 100% ± 2 digits
Pulse rate 25 to 250 bpm ± 3 digits
Low perfusion 25 to 250 bpm ± 3 digits
Compatibility
Compatible with Philips IntelliVue* systems†
MP40
MP50
MP60
MP70
MP80
MP90
MX800

Order Information

Product Technology

Get Accurate Data – Quickly

Nellcor™ pulse oximetry with OxiMax™ technology specifies a highly accurate measurement of SpO2, even in some of the most challenging patients.([FOOTNOTE=NCT01720355 at Clinical Trials.gov.],[ANCHOR=],[LINK=])

The Nellcor™ SpO2 forehead sensor:

  • Provides an expanded LoSat accuracy range of 60% – 80% SpO2 +/-3 and delivers reliable readings in challenging conditions4
  • Designed for an accessible sensor site-the forehead is generally easier to reach and less prone to motion than hands
  • Can be used with mechanically ventilated patients
  • Enables monitoring of patients from pediatric (weighing more than 10 kg) to adult
  • Single-patient use, featuring long-lasting, four-layer adhesive