placeNew Zealand

Overview

Consistent port-site closures without removing the port([FOOTNOTE=Based on internal validation report #RE00098009 Rev A, DoubleTime VersaOne™ fascial closure system Miami lab VOC report: 13 out of 16 surgeons surveyed agreed. March 28, 2017.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal validation report #RE00062341 Rev A, Summative usability of project DoubleTime VersaOne™ fascial closure system. Aug. 24–25, 2016.],[ANCHOR=],[LINK=])

The VersaOne™ fascial closure system is a unique all-in-one1 solution that serves as a trocar and a fascial closure device to deliver:

  • Consistent port-site closure1
  • Added procedural efficiency1,†
  • Ease of use1

Features

Access and closure with a single device

The VersaOne™ fascial closure system brings consistent suture placement to laparoscopic closures.It also:

  • Eliminates the need to remove the trocar before closing1,2
  • Makes reinsufflation unnecessary — pneumoperitoneum can be maintained throughout the procedure2
  • Allows tissue layers to remain aligned2

Key features

The cannula window and guide help facilitate closure of the fascia at 5 mm on either side of the cannula defect([FOOTNOTE=Based on internal report #RE00003570, VOC summary detailing customer requirements for project DoubleTime, as compiled from surveys at SAGES 2013: 16 out of 16 surgeons agreed. Nov. 5, 2014.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal report #RE00079705, Fascial closure system bite size verification. Nov. 5, 2014.],[ANCHOR=],[LINK=]),([FOOTNOTE=Israelsson LA. Abdominal incision closure: small but important bites. Lancet. 2015;386(10000):1216–1218.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal VOC summary report # RE00003541, Customer requirements for project DoubleTime from surveys at SAGES 2013:16 out of 16 surgeons surveyed agreed. May 6, 2013.],[ANCHOR=],[LINK=])

  • The black visual indicators  aid  in  consistent suture placement1
  • The needle tip and grasping features of the suture passer allow for subcutaneous insertion and grasping of the suture
  • The low-profile ergonomic obturator is available in an optical or bladed tip
/content/dam/covidien/library/global/en/product/trocars-and-access/versaone-fascial-closure-system-in-use-g.jpg
Order Information
Order Code Description Unit of Measure Quantity
ONB12STFCS VersaOne™ Fascial Closure System Optical Trocar Box 6
B12STFCS VersaOne™ Fascial Closure System Bladed Trocar Box
6
FCSPASS VersaOne™ Fascial Closure System Reusable Suture Passer Box 1

Order Information

Award-Winning Design

The Medical Design Excellence Awards named our VersaOne™ fascial closure system a Gold Winner in their ER and OR Tools category. 

Medical Design Excellence Awards
  • †Saves time compared to standalone closure device, suture passers, and hand sutures.