placeNew Zealand

Overview

Same trusted brand. Advanced access design.

Shiley™ tracheostomy tubes have a 40-year history with over 760 million products used around the world.

The Shiley™ flexible evac tracheostomy tube with TaperGuard™ cuff technology offers clinician-inspired enhancements to the Shiley™ flexible adult tracheostomy portfolio, and features:

  • The addition of an evac lumen to enable removal of secretions from the subglottic space
  • The Shiley™ taper-shaped TaperGuard cuff
  • A translucent outer cannula with beveled tip

This product can be used for the initial tracheostomy insertion in the ICU to remove potentially bacteria producing fluids1, which are recognized as a primary source for ventilator associated pneumonia (VAP).

Shiley™ flexible evac tracheostomy tubes were designed with a slightly larger outer diameter, compared to standard Shiley™ flexible tracheostomy tubes, to support the evac lumen for secretion removal.

Seal the path to a smooth recovery.

Learn how the Shiley™ flexible evac tracheostomy tube with TaperGuard™ cuff is designed to remove secretions.

View Info Sheet

Features

Shiley™ evac technology

  • The Shiley™ TaperGuard Evac oral endotracheal tube incorporates evac technology that has been shown to reduce VAP by an average of 50% compared to standard endotracheal tubes without subglottic secretion.2

Thermosensitive transparent outer cannula

  • Thinner, less bulky cuff reduces insertion force by 48%3
  • Beveled tip on all product configurations eases percutaneous insertion4
  • Smooth, continuous curvature enables proper positioning
  • Sizing — I.D., O.D., length, and tube curvature — is comparable to that of earlier Shiley™ products
  • Made of non-DEHP material

TaperGuard™ low pressure, low volume cuff

  • Reduces fluid leakage by 99 percent compared to legacy Shiley™ tracheostomy products1
  • Low pressure, low volume design applies less lateral wall pressure on trachea in benchtop study5
  • Thinner material enables more even distribution of wall pressure5

May reduce the risk of irritation and skin breakdown

  • Soft, transparent flange material is designed to conform to the patient’s anatomy and may help reduce the risk of skin breakdown6
  • Custom designed flange openings improve airflow to sensitive skin, and are offset to help reduce contact with the patient’s skin
Order Information
Shiley™ Flexible Evac Tracheostomy Tube with Disposable Inner Cannula
Order Code Unit of Measure Quantity

4CN65ED

Box 1

5CN70ED

Box 1

6CN75ED

Box 1

7CN80ED

Box 1

8CN85ED

Box 1

9CN90ED

Box 1

10CN10ED

Box 1
SHILEY™ FLEXIBLE DISPOSABLE INNER CANNULA
ORDER CODE UNIT OF MEASURE QUANTITY

4IC65

Box 10

5IC70

Box 10

6IC75

Box 10

7IC80

Box 10

8IC85

Box 10

9IC90

Box 10

10IC10

Box 10
SHILEY™ FLEXIBLE EVAC TRACHEOSTOMY TUBE WITH Reusable INNER CANNULA
ORDER CODE UNIT OF MEASURE QUANTITY

4CN65ER

Box 1

5CN70ER

Box 1

6CN75ER

Box 1

7CN80ER

Box 1

8CN85ER

Box 1

9CN90ER

Box 1

10CN10ER

Box 1

Order Information

References

 

 

1. Internal benchtop testing results. Results reflect the Shiley™ flexible adult tracheostomy tube with TaperGuard™ cuff, disposable inner cannula tubes ability to titrate/control ventilator air leak in comparison to the Shiley™ tracheostomy tube cuffed with disposable inner cannula (DCT). Benchtop test #10122514.

2. Muscedere J, Rewa O, McKechnie K, Jiang X, Laporta D, Heyland DK. Subglottic secretion drainage for the prevention of ventilator-associated pneumonia: a systematic review and meta-analysis. Crit Care Med. 2011;39(8):1985-1991. 

3. Internal bench-top testing results. Results reflect testing the Shiley™ flexible adult tracheostomy tube with TaperGuard™ cuff, disposable inner cannula versus the Shiley™ DCT tracheostomy tube with disposable inner cannula at the same cuff pressure of 25 cm H2O. Benchtop test #RE00127642 Rev A.

4. Servillo, Giuseppe, and P. Pelosi. Percutaneous Tracheostomy in Critically Ill Patients. Springer, p. 106 2015.

5. Maguire S, Haury F, Jew K. An in vitro comparison of tracheostomy tube cuffs. Medical Devices (Auckland, N.Z.) New Zealand, 8, 185-192. April 21, 2015.

6. Internal test report. Shiley™ adult flexible tracheostomy tube with TaperGuard™ cuff, disposable inner cannula claims test report #10122514, water vapor transmission rate through tracheostomy flange #10119661.