With the thickest indicated tissue range for any stapler on the market (2.25 mm – 3.00 mm)1, the Endo GIA™ radial reload delivers optimal performance, even in challenging cases.
In colorectal procedures, the Endo GIA™ radial reload is setting new standards for access, maneuverability and staple line security in LAR procedures. It may provide surgeons uncompromised access and visibility deep in the pelvis.
For thoracic procedures, the unique design and 360 degree rotation provides multiple angles and enhances access in the chest cavity for both open and VATS procedures compared to linear reloads. The Endo GIA™ radial reload may produce less stress during compression and clamping([FOOTNOTE=Based on internal test report #PCG-007 rev 1, When compared to Echelon Flex™* green reloads as part of an analysis comparing different stapler designs and their performance and impact on tissues under compression using two-dimensional finite element analysis. Sept. 2, 2011.],[ANCHOR=],[LINK=]),†, allows greater perfusion into the staple line([FOOTNOTE=When compared to Ethicon Echelon Flex™* uniform staple reloads as part of a bench study conducted in murine models, the vascular volume was statistically superior with Tri-Staple™ (p=.011).],[ANCHOR=],[LINK=]),†, and provides outstanding performance in variable tissue thicknesses.([FOOTNOTE=Based on internal test report #PCG-001, Tyvek pull-apart test comparing Echelon(TM*) and Tri-Staple™ technology (data on file at Medtronic). March 2011.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #PCG-004, Undercrimp comparisons in increasing pads of foam between Echelon™* and Tri-Staple™ technology (data on file at Medtronic). January 2012.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #PCG-006, Staple Formation Comparison between Medtronic EGIA60AXT and Ethicon ECR60G in an Ex-Vivo Tissue Model (data on file at Medtronic). January 2012.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #PCG-018, 2D FEA of Linear Staplers (data on file at Medtronic). November 2012.
],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #PCG-019, Comparative Test of Medtronic Endo GIA™ Black Reloads with Tri-Staple™ Technology and Ethicon ECHELON FLEX™* Black Reloads (data on file at Medtronic). June 2014.],[ANCHOR=],[LINK=]),†
†Pre-Clinical results may not correlate with clinical performance in humans.