placeNew Zealand

Overview

Flexible. Compact. Intuitive.

The Nellcor™ bedside SpO2 patient monitoring system, PM100N, provides at-a-glance access to real-time patient respiratory status information including continuous SpO2 and pulse rate monitoring and trending data. The compact monitor can be placed at the patient’s bedside or easily transported using the convenient, built-in handle.([FOOTNOTE=Mannheimer PD, Nooshin AA et al. NellcorTM OximaxTMPulse Oximeter Accuracy, White Paper, 2006.],[ANCHOR=],[LINK=])

With home care and sleep study modes, the PM100N has functionality for non-hospital settings. The system has password-protection to ensure safe utilisation by non-clinical users, and the ability to conveniently download data for further data analysis.

The monitor incorporates the latest Nellcor™ digital signal processing technology for reliable readings even during low perfusion, motion, and other forms of signal interference, as well as SatSeconds™ alarm management to help distinguish meaningful alarms from transient events.1

Features

  • Displays plethysmographic waveforms, pulse amplitude and real-time SpO2 and pulse rate data([FOOTNOTE=Refer to PM100N Operators Manual],[ANCHOR=],[LINK=])
  • 96-hour trend memory with data captured every four seconds for quick review of changes in patient status
  • Includes SatSeconds™ alarm management, a clinician-controlled feature that has been proven to reduce nuisance alarms([FOOTNOTE=Brostowicz HM, Khodayar Rais-Bahrami K. Oxygen saturation monitoring in the neonatal intensive care unit: evaluation of a new alarm management. In: Program and abstracts of the American Academy of Pediatrics National Conference & Exhibition; October 17-20, 2009; Washington, D.C.],[ANCHOR=],[LINK=])
  • Password protected homecare and sleep study modes
    • Both homecare and sleep study modes meet IEC 60601-1-11 for home health equipment to promote the safe and effective use of the monitor by lay users in the non-hospital setting. Optional homecare support package to ease patient and caregiver burden
Order Information
Order Code Description Unit of Measure Quantity
PM100N Nellcor™ Bedside SpO2 Patient Monitoring System Each 1
Performance
Measurement Range
SpO2: 1% to 100%
Pulse rate: 20 to 250 beats per minute (bpm)
Pulse amplitude: 0.03% to 20%
Measurement Accuracy
Saturation
Adult: 70% to 100% ± 2 digits
Adult and neonate low sat: 60% to 80% ± 3 digits
Neonates: 70% to 100% ± 2 digits
Low perfusion: 70% to 100% ± 2 digits
Adult and neonate with motion: 70% to 100% ± 4 digits
Pulse rate: 20 to 250 bpm ± 3 digits
Low perfusion: 20 to 250 bpm ± 3 digits
Pulse rate
Adult and neonate: 20 to 250 bpm ± 3 digits
Low perfusion: 20 to 250 bpm ± 3 digits
Adult and neonate with motion: 20 to 250 bpm ± 5 digits
Electrical
Instrument
Power requirements: 100 to 240 VAC, 50/60 Hz, 45 VA
Fuse rating: Fast‑acting 2 A 32VAC/DC,
  Fast‑acting 500 mA 32VAC/50DC
Battery  
Type: Lithium ion
Battery capacity: Minimum of five hours using new, fully charged battery with no alarms; optional 10-hour battery
Environmental
Operating Temperature
Instrument 5 °C to 40 °C (41 °F to 104 °F)
Transport/Storage Temperature (in shipping carton) -20 °C to 60 °C (-4 °F to 140 °F)
Operating Humidity
15% to 93% noncondensing
Operating Altitude
-170 m to 4877 m (-557 ft to 16,000 ft)
Physical Characteristics
Weight: 1.5 kg (3 lbs)
Size: 82 H x 255 W x 155 D (mm), (3.23 H x 10.04 W x 6.10 D (in)
Equipment Compliance
Standards Compliance*
• IEC 60601-1:2005+A1:2012, EN 60601-1:2006/AC:2010
• IEC 60601-1:1998 + A1:1991 +A2:1995, EN 60601-1:1990 +A11:1993 +A12:1993 +A13:1996
• IEC 60601-1-2:2007, EN60601-1-2:2007
• IEC 60601-1-6:2010, EN 60601-1-6:2010 +A1:2013
• IEC 60601-1-8:2006, EN 60601-1-8:2006 +A1:2012
• IEC 60601-1-11:2010, EN 60601-1-11:2010
• ISO 9919:2005, EN ISO 9919:2009
• ISO 80601-2-61:2011, EN ISO 80601-2-61:2011
• CAN/CSA C22.2 No. 601.1 M90
• UL 60601-1: 1st edition
• 802.11 B/G/N WLAN connectivity
 * This list is not exhaustive. For more information regarding compliance information please contact your local sales representative.
Equipment Classifications
• Type of protection against electric shock Class 2 (internally powered)
• Degree of protection against electric shock Type BF – Applied part
• Mode of operation Continuous
• Electromagnetic compatibility IEC 60601-1-2:2007
• Liquid ingress IP 22
Output
• Trend data download via wired or USB for archiving or data analysis
Display/Indicators
• Pulse amplitude indicator (eight segments)
• Visual indicators Pulse search, audible alarms silenced or off, interference indicator, battery charging, and SatSeconds alarm management clock, pleth wave form
Alarms
• SatSeconds alarm management
• Audible and Visual alarms for high/low saturation and pulse rate, low battery, sensor off, and sensor disconnect
• Categories Patient status and system status
• Priorities Low, medium and high
• Notification Audible and visual
• Setting Default, institutional and last setting
• Alarm system delay <10 s
Optional Accessories
• 10 and 15 hour battery
• Adapter plate
• GCX wall mount arm and channel
• GCX roll stand
• Carrying case
Available Modes
• Standard – Hospital, hospital‑type facilities, and intra‑hospital transport
• Homecare – Simplified monitoring for use in the home by caregivers
• Sleep Study – Muted audible and visual queues to aid sleep studies
Connectivity
• Supports wired and USB trend data export to an external personal computer for archiving or data analysis
• Nurse call capability
Simple Setup and Maintenance
The Nellcor™ Bedside SpO2 Patient Monitoring System meets medical electrical equipment standards, is RoHs compliant, and enables hospital staff to set institutional defaults, replace the battery, perform diagnostics to troubleshoot performance issues, and perform on‑site maintenance on the monitor.

Order Information