Overview

Superior Performance From Many Angles†,2

Older, non-articulating fixation devices present several challenges in laparoscopic ventral hernia repair. 

Accessing the mesh can be difficult, fixation strength can be less than ideal, and procedural costs can increase dramatically when more than one device is needed in a single procedure.1,2,3

ReliaTack™ articulating reloadable fixation device is revolutionizing hernia repair.

Articulate to 65 degrees to experience superior access and stronger fixation.1,2  Use cost effective reloads to lower the cost of care.3‡

Finally, experience the versatility of ReliaTack™ device. Choose between standard or deep purchase tacks to meet your unique patient and procedural needs.

Features

Articulation

Articulation delivers perpendicular tack deployment and minimizes mesh shift£,1,4

  • Consistent tack purchase when shaft is angled at 30˚, 45˚, 65˚ and 90˚ 2
  • Reduces mesh shift during tacking£,1
  • May eliminate contralateral ports£,1

Reloadable

Articulation and interchangeable deep purchase tack reloads may reduce cost of care.§,1,3

  •  Savings per case:
    • Up to $385 compared to SecureStrap ™* device 3
    • Up to $337 compared to SorbaFix™* device 3
  • May save up to $100 per case by potentially eliminating contralateral ports,5
  • Up to 60 firings eliminates the need for multiple fixation devices per case‡,6

Ergonomic Handle 

Low profile handle with perceptible click provides audible and tactile feedback to confirm that the tack has been successfully deployed. 

Order Information
Order Code Description Unit of Measure Quantity
RELTACK3X10SW ReliaTack™ Articulating Reloadable Fixation Device with 30 Absorbable Tacks Box 6
RELTACK10RSW ReliaTack™ Articulating Reloadable Fixation Device Reload with 10 Standard Purchase Absorbable Tacks Box 6
RELTACK5RSW ReliaTack™ Articulating Reloadable Fixation Device Reload with 5 Standard Purchase Absorbable Tacks Box 6
RELTACK4XDPTSW ReliaTack™ Articulating Reloadable Fixation Device with 3x 8 Deep Purchase Tack Reloads and 1x 5 Deep Purchase Tack Reload Box 6
RELTACK8RDPTSW ReliaTack™ Articulating Reloadable Fixation Device Reload with 8 Deep Purchase Absorbable Tacks Box 6
RELTACK5RDPTSW ReliaTack™ Articulating Reloadable Fixation Device Reload with 5 Deep Purchase Absorbable Tacks Box 6

Order Information

Technology

Delivers Superior Access£,1, Stronger Fixation†,2 and Lower Cost of Care.§,3

Superior Access£,1

Articulation delivers perpendicular tack deployment and minimizes mesh shift£,1,4

  • Consistent tack purchase when shaft is angled at 30˚, 45˚, 65˚ and 90˚ 2
  • Reduces mesh shift during tacking£,1
  • May eliminate contralateral ports£,1

Stronger Fixation†,2

Articulation and screw-like tacks deliver superior fixation strength compared to both absorbable and permanent fixation devices when the shaft is angled at 30°, 45°, 65° and 90°.

  • 3.3x stronger than Securestrap™* device
  • 1.9x stronger than Sorbafix™* device
  • 1.5x stronger than ProTack™ device
  • 3.9x stronger than OptiFix™* device
  • 1.6x stronger than ReliaTack™ device
  • 1.7x stronger than CapSure™* device
  • 1.5x stronger than ProTack™ device

Lower Cost of Care§,3

Up to 60 firings eliminates the need for multiple fixation devices per case6,‡

  • May save up to $461 per case compared to SecureStrap™* device and SorbaFix™* device3,5,††,‡‡¶

  • £ In comparison to AbsorbaTack™ fixation device 

  • § Based on potential for eliminating contralateral ports and average savings when 31-50 tacks are needed 

  • ‡ When 30-60 tacks are needed

  • † Compared to Absorbable and Permanent Fixation Devices Commercially Available, which include SecureStrap™* device, SorbaFix™* device, OptiFix™* device, Capsure™* device, ProTack™ device and ReliaTack™ device with Standard Purchase Tacks when the shaft is angled at 30°, 45°, 65° and 90° (bench testing)

  • †† Average of greatest estimated per-case savings over SecureStrap™* and SorbaFix™* when 31-50 tacks are needed

  • ‡‡ Articulation may save up to $100 per case by potentially eliminating contralateral ports

  • 1. Mesh Overlap Claims Testing Report R0054140 P-Value= 0.007 (March 2014)

  • 2. ReliaTack Deep Purchase Tack Shear Pull Test RE00010135-1 P-value= 0.00 (October 2015)

  • 3. ReliaTack™ DPT Cost Comparison,  ReliaTack™ Deep Purchase Internal Average Cost Data compared to SecureStrap™* and SorbaFix™* IMS Data

  • 4. Design Verification – Articulation Angle Engineering Report R2165-050 (March 2014)

  • 5. IMS Trocar ASP Analysis. Evaluates Average Trocar Cost (March 2014)