Valleylab™ PolyHesive™ Corded Patient Return Electrodes

Product Details

Valleylab™ REM and Non-REM PolyHesive™ single use, corded patient return electrodes are recognized worldwide for quality, safety, and innovative technology. All return electrodes are manufactured with our patented PolyHesive™ II high moisture, conductive adhesive hydrogel.

Order Information

Valleylab™ PolyHesive™ Corded Patient Return Electrodes

Product Attributes
Order Code Description Unit of Measure Quantity
E7506 Valleylab™ Non-REM Polyhesive™ Patient Return Electrode, 9' (2.7 m) Case 50
E7507 Valleylab™ REM Polyhesive™ Adult Patient Return Electrode, 9' (2.7 m) Case 50
E7507DB Valleylab™ REM Polyhesive™ Adult Patient Return Electrode, 15' (4.6 m) Case 50
E7510-25 Valleylab™ REM Polyhesive™ Infant Patient Return Electrode, 9' (2.7 m) Case 25
E7510-25DB Valleylab™ REM Polyhesive™ Infant Patient Return Electrode, 15' (4.6 m) Case 25
E7512 Valleylab™ REM Pad, Neonatal Hydrogel Patient Return Electrode 9' (2.7 m)
Case 12

Valleylab™ PolyHesive™ Non-Corded Patient Return Electrodes

Product Details

Valleylab™ REM PolyHesive™ single use, non-corded patient return electrodes are recognized worldwide for quality, safety, and innovative technology. All return electrodes are manufactured with our patented PolyHesive™ II high moisture, conductive adhesive hydrogel.

Order Information

Valleylab™ PolyHesive™ Non-Corded Patient Return Electrodes

Product Attributes
Order Code Description Unit of Measure Quantity
E7508 Valleylab™ REM Polyhesive™ Adult Cordless Patient Return Electrode Case 100
E7509 Valleylab™ REM Polyhesive™ Adult Cordless Patient Return Electrode, 5 per pkg Case 50
E7509B Valleylab™ REM Polyhesive™ Adult Cordless Patient Return Electrode, 50 per pkg Case 600
E0560 Valleylab™ REM Patient Return Electrode Cord, Reusable, 15' (4.6 m) Each 1

Overview

Proven Safe in More than 200 Million Procedures

Valleylab™ patient return electrodes are recognized worldwide for quality, safety, and innovative technology. All return electrodes are manufactured with our patented PolyHesive™ II high moisture, conductive adhesive hydrogel that provides the performance of a gel without the gel mess.

PolyHesive™ II Hydrogel Benefits

  • Water-based hydrogel lowers skin resistance.
  • Unique elongation fills patient skin irregularities and minimizes contact voids to improve the total electrical conduction area.

Electrode Benefits

  • Surface area disperses current over large area, minimizing heat buildup.
  • Acrylic adhesive improves pad contact quality and provides a moisture barrier to significantly reduce the potential for fluid invasion.
  • Adult, infant (<30 lb.), and neonatal (<6 lb.) sizes available.
  • Non-irritating* and non-sensitizing*

REM™ Contact Quality Monitoring System

  • The exclusive Valleylab REM™ system monitors patient impedance levels, automatically deactivating the generator if a fault at the patient return electrode is detected.
  • REM™ is an integral part of the Valleylab Full Circuit™ system standardization program.