Sentrant™ Introducer Sheath

EVAR and TEVAR Procedures

Overview

Achieve improved seal in both straightforward and complex anatomies with Sentrant™ introducer sheath.*

Indications

See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative and/or consult the Medtronic website.

The Medtronic Sentrant™ Introducer Sheaths with Hydrophilic Coating are intended to provide a conduit for the insertion of diagnostic or endovascular devices into the vasculature and to minimise blood loss associated with such insertions.

Product details

Sentrant Introducer Sheath Design

Sentrant™ Introducer Sheath features

The Sentrant™ Introducer Sheath is the choice for superior hemostasis.*

  1. Smooth dialator to sheath transition
  2. Radiopaque marker band
  3. Reinforced coiled tubing
  4. Two working lengths: 28 cm and 64 cm
  5. Hydrophilic coating
  6. Locking mechanism on dilator handle
  7. Guidewire diameter: 0.035" / 0.89 mm

Compatible with Endurant™ and Valiant Navion™ stent graft delivery systems

Engineered to deliver procedural confidence

  • EnsureSeal Technology delivers superior leak resistance versus competitors*
  • Coil-reinforced tubing for added stability and kink resistance
  • Maintains lubricity after multiple insertions
  • Radiopaque dilator shaft and sheath tip for accurate visualization and guidance
  • 64 cm configuration available for broader anatomical applicability
  • Compatible with a wide range of endovascular portfolios

 

Superior leak resistance versus competitors*

The Sentrant™ Introducer Sheath had zero leakage on 0.035" / 0.89 mm guidewire.

Manuals and technical guides

Instructions for Use
Find this technical manual in the Medtronic Manual Library or in the product labeling supplied with each device.

Model specifications

Ordering Information

Model Number Sheath
Size
(F)
Working
Length
(cm)
SENSH1228W 12 28
SENSH1428W 14 28
SENSH1628W 16 28
SENSH1828W 18 28
SENSH2028W 20 28
SENSH2228W 22 28
SENSH2428W 24 28
SENSH2628W 26 28
SENSH1264W 12 64
SENSH1464W 14 64
SENSH1664W 16 64
SENSH1864W 18 64
SENSH2064W 20 64
SENSH2264W 22 64
SENSH2464W 24 64
SENSH2664W 26 64
*

Leak Resistance Bench Test Data on file at Medtronic. Test data not indicative of clinical performance. Bench Test compared Cook Check-Flo Performer™* Introducer Sheath 16 Fr and Gore DrySeal™* Flex 16 Fr to Sentrant™ 16 Fr. Graph shows average leakage over an extrapolated 2.5 hour procedure.

™* Third party brands are trademarks of their respective owners.

Disclaimer: 64 cm working length sheath may not be available in your region or country. Please consult the approved indications for use. Content on specific Medtronic products is not intended for users in markets that do not have authorisation for use.

CE mark 2797