Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
The Endurant™ family of products provides the standard of care with a legacy of clinical success for the treatment of abdominal aortic aneurysm (AAA).
Contact UsEndurant™ IIs stent graft is a three-piece system that:
Accurate placement and controlled deployment.2 Flexible, kink-resistant delivery system facilitates stent graft delivery. Tip capture for precise positioning adjustments, including adjustment of placement proximally or distally.
Continuous seal, fixation, and graft conformability.3 M-shaped proximal stents provide wall apposition and circumferential conformability.
Durable hemostatic barrier and resistance against type II endoleaks.4 High density, multifilament polyester graft material provides lower porosity for resistance against type II endoleaks.
Deployment, capture, and release of the Endurant™ II stent.
Find this technical manual in the Medtronic Manual Library, in the product labeling supplied with each device.
ETBF | 23 | 13 | C | 124 | EE | 18 |
ETBF | 23 | 13 | C | 145 | EE | 18 |
ETBF | 23 | 13 | C | 166 | EE | 18 |
ETBF | 23 | 16 | C | 124 | EE | 18 |
ETBF | 23 | 16 | C | 145 | EE | 18 |
ETBF | 23 | 16 | C | 166 | EE | 18 |
ETBF | 25 | 13 | C | 124 | EE | 18 |
ETBF | 25 | 13 | C | 145 | EE | 18 |
ETBF | 25 | 13 | C | 166 | EE | 18 |
ETBF | 25 | 16 | C | 124 | EE | 18 |
ETBF | 25 | 16 | C | 145 | EE | 18 |
ETBF | 25 | 16 | C | 166 | EE | 18 |
ETBF | 28 | 13 | C | 124 | EE | 18 |
ETBF | 28 | 13 | C | 145 | EE | 18 |
ETBF | 28 | 13 | C | 166 | EE | 18 |
ETBF | 28 | 16 | C | 124 | EE | 18 |
ETBF | 28 | 16 | C | 145 | EE | 18 |
ETBF | 28 | 16 | C | 166 | EE | 18 |
ETBF | 28 | 20 | C | 124 | EE | 18 |
ETBF | 28 | 20 | C | 145 | EE | 18 |
ETBF | 28 | 20 | C | 166 | EE | 18 |
ETBF | 32 | 16 | C | 124 | EE | 20 |
ETBF | 32 | 16 | C | 145 | EE | 20 |
ETBF | 32 | 16 | C | 166 | EE | 20 |
ETBF | 32 | 20 | C | 124 | EE | 20 |
ETBF | 32 | 20 | C | 145 | EE | 20 |
ETBF | 32 | 20 | C | 166 | EE | 20 |
ETBF | 36 | 16 | C | 145 | EE | 20 |
ETBF | 36 | 16 | C | 166 | EE | 20 |
ETBF | 36 | 20 | C | 145 | EE | 20 |
ETBF | 36 | 20 | C | 166 | EE | 20 |
ESBF | 23 | 14 | C | 103 | EE | 18 |
ESBF | 25 | 14 | C | 103 | EE | 18 |
ESBF | 28 | 14 | C | 103 | EE | 18 |
ESBF | 32 | 14 | C | 103 | EE | 20 |
ESBF | 36 | 14 | C | 103 | EE | 20 |
ETLW | 16 | 10 | C | 82 | EE | 14 | 136 | 155 |
ETLW | 16 | 10 | C | 93 | EE | 14 | 147 | 166 |
ETLW | 16 | 10 | C | 124 | EE | 14 | 178 | 177–197 |
ETLW | 16 | 10 | C | 146 | EE | 16 | 196 | 196-216 |
ETLW | 16 | 10 | C | 156 | EE | 16 | 210 | 209–229 |
ETLW | 16 | 10 | C | 199 | EE | 16 | 253 | 252–272 |
ETLW | 16 | 13 | C | 82 | EE | 14 | 136 | 155 |
ETLW | 16 | 13 | C | 93 | EE | 14 | 147 | 166 |
ETLW | 16 | 13 | C | 124 | EE | 14 | 178 | 177–197 |
ETLW | 16 | 10 | C | 146 | EE | 16 | 196 | 196-216 |
ETLW | 16 | 13 | C | 156 | EE | 16 | 210 | 209–229 |
ETLW | 16 | 13 | C | 199 | EE | 16 | 253 | 252–272 |
ETLW | 16 | 16 | C | 82 | EE | 14 | 136 | 135–155 |
ETLW | 16 | 16 | C | 93 | EE | 14 | 147 | 146–166 |
ETLW | 16 | 16 | C | 124 | EE | 14 | 178 | 177–197 |
ETLW | 16 | 13 | C | 146 | EE | 16 | 196 | 196-216 |
ETLW | 16 | 16 | C | 156 | EE | 16 | 210 | 209–229 |
ETLW | 16 | 16 | C | 199 | EE | 16 | 253 | 252–272 |
ETLW | 16 | 20 | C | 82 | EE | 16 | 136 | 155 |
ETLW | 16 | 20 | C | 93 | EE | 16 | 147 | 166 |
ETLW | 16 | 20 | C | 124 | EE | 16 | 178 | 177–197 |
ETLW | 16 | 16 | C | 146 | EE | 16 | 196 | 196-216 |
ETLW | 16 | 20 | C | 156 | EE | 16 | 210 | 209–229 |
ETLW | 16 | 20 | C | 199 | EE | 16 | 253 | 252-272 |
ETLW | 16 | 24 | C | 82 | EE | 16 | 136 | 155 |
ETLW | 16 | 24 | C | 93 | EE | 16 | 147 | 166 |
ETLW | 16 | 24 | C | 124 | EE | 16 | 178 | 177–197 |
ETLW | 16 | 24 | C | 146 | EE | 16 | 196 | 196-216 |
ETLW | 16 | 24 | C | 156 | EE | 16 | 210 | 209–229 |
ETLW | 16 | 24 | C | 199 | EE | 16 | 253 | 252–272 |
ETLW | 16 | 28 | C | 82 | EE | 16 | 136 | 155 |
ETLW | 16 | 28 | C | 93 | EE | 16 | 147 | 166 |
ETLW | 16 | 28 | C | 124 | EE | 16 | 178 | 177–197 |
ETLW | 16 | 28 | C | 146 | EE | 16 | 196 | 196-216 |
ETLW | 16 | 28 | C | 156 | EE | 16 | 210 | 209–229 |
ETLW | 16 | 28 | C | 199 | EE | 16 | 253 | 252–272 |
ETCF | 23 | 23 | C | 49 | EE | 18 |
ETCF | 25 | 25 | C | 49 | EE | 18 |
ETCF | 28 | 28 | C | 49 | EE | 18 |
ETCF | 32 | 32 | C | 49 | EE | 20 |
ETCF | 36 | 36 | C | 49 | EE | 20 |
ETTF | 23 | 23 | C | 70 | EE | 18 |
ETTF | 25 | 25 | C | 70 | EE | 18 |
ETTF | 28 | 28 | C | 70 | EE | 18 |
ETTF | 32 | 32 | C | 70 | EE | 20 |
ETTF | 36 | 36 | C | 70 | EE | 20 |
ETUF | 23 | 14 | C | 102 | EE | 18 |
ETUF | 25 | 14 | C | 102 | EE | 18 |
ETUF | 28 | 14 | C | 102 | EE | 18 |
ETUF | 32 | 14 | C | 102 | EE | 20 |
ETUF | 36 | 14 | C | 102 | EE | 20 |
ETEW | 10 | 10 | C | 82 | EE | 14 |
ETEW | 13 | 13 | C | 82 | EE | 14 |
ETEW | 20 | 20 | C | 82 | EE | 16 |
ETEW | 24 | 24 | C | 82 | EE | 16 |
ETEW | 28 | 28 | C | 82 | EE | 18 |
Choose from a complete portfolio of market-leading aortic vascular therapies to treat aneurysm disease.
Download catalogDelivery success = successful vascular access and delivery of the device to the intended anatomical treatment site. Deployment success = successful deployment of the device in the intended site and the successful removal of the delivery system. Endurant™ US IDE trial: Makaroun M. One-year outcomes of the U.S. regulatory trial of the Endurant™ stent graft system.
The limb mates with the AUI stent graft on the ipsilateral side.
These calculations assume the minimum 30 mm overlap between the bifurcated stent graft and the contralateral iliac limb per the Endurant II Stent Graft System Instructions for Use. When using the 124 mm length bifurcated stent graft, subtract 10 mm from Total Contralateral Covered Length with Bifurcated.
The 3–5 stent overlap is available only with select limbs. Please refer to the Instructions for Use for more information.
Data on file Medtronic.
Makaroun M Tuchek M, Massop D, et al. One-year outcomes of the US regulatory trial of the Endurant™ stent graft system. J Vasc Surg. September 2011;54(3):601–608. Endurant™ US IDE trial.
Based on internal test report DVR7245 Design Verification Report: Endurant Stent Graft System conducted January–July 2007. Bench test data may not be indicative of clinical performance.
Wakefield TW, Shulkin BL, Fellows EP, Petry NA, Spaulding SA, Stanley JC. Platelet reactivity in human aortic grafts: a prospective, randomized midterm study of platelet adherence and release products in Dacron and polytetrafluoroethylene conduits. J Vasc Surg. February 1989;9(2):234–243.