SelectSecure™ MRI SureScan™ Model 3830 lumenless lead

Model 3830 is the first and only CE-approved pacing lead for conduction system pacing, to help treat bradycardia patients who have a pacemaker.

Overview

CE-approved for His-bundle pacing and left bundle branch area pacing

The 3830 lead is the first and only CE-approved lead for providing conduction system pacing, including both His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP).*

A system composed of a SelectSecure 3830 MRI lead and a single or a dual chamber Medtronic pacing system is approved for conduction system pacing.

Product details

Proven safe

3830 use in the left bundle branch area is supported by real-world evidence encompassing more than 20 000 patients.1-3
 

SelectSecure MRI SureScan 3830 lead and Azure XT DR MRI SureScan pacemaker inside a pink decorative circle

Proven design

3830’s central cable, small 4.1 French lumenless lead body and fixed helix are designed to minimize lead mechanical stress.

  • More than 500 000 leads implanted4
  • First implant over 20 years ago5

Proven reliable

The fatigue performance of the 3830 lead in a left bundle branch area position compares to performance in the RV (98% reliability, 95% CI) based on simulated 10-year testing.6


 

First and only MR conditional

MR Conditional lead for His bundle pacing and left bundle branch area pacing, when paired with Medtronic MRI SureScan systems.

Related catheters

SelectSite™ catheter, model C304-HIS

Preshaped deflectable catheter with out-of-plane “His” curve.

Preshaped catheter, model C315HIS

Preshaped catheter with out-of-plane “His” curve.

SelectSite™ deflectable catheter

Request more information

Indications: The Model 3830 lead is intended for pacing and sensing in the right atrium or right ventricle. It is also intended for pacing and sensing at the bundle of His or in the left bundle branch area as an alternative to right ventricular pacing in a single or dual chamber pacing system. (SelectSecure™ MRI SureScan™ 383059, 383069, 383074 Technical manual. https://manuals.medtronic.com/manuals/

References

1

Ellenbogen KA, Left bundle branch area pacing using the Model 3830 lead: A systematic literature review and meta-analysis, Presented at APHRS 2022. 19 November 2022. Singapore.​

2

Vijayaraman P, Model 3830 Lead Performance for Left Bundle Branch Area Pacing: Results from a Multi-Center Registry, Presented at APHRS 2022. 19 November 2022. Singapore.​

3

Kron J, Performance of Model 3830 Left Bundle Branch Area Pacing: Results from CareLink and Registration Data, Presented at APHRS 2022. 18 November 2022. Singapore.​

4

Andrade C. 500,000 3830 Patients. October 2023. Medtronic data on file.

5

Gammage MD, Lieberman RA, Yee R, et al. Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance. PACE Pacing Clin Electrophysiol. 2006;29(8):858-865.

6

Zou et al. Clinical use conditions of lead deployment and simulated lead fracture rate in left bundle branch area pacing. J Cardiovasc Electrophysiol. 2023 Mar;34(3):718-725​.

CE Mark