Healthcare Professionals
Launcher
Coronary Guide Catheter
You just clicked a link to go to another website. If you continue, you will leave this site and go to a site run by someone else.
Medtronic Canada does not review or control the content on the other website, and is not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site not be licensed for sale in Canada.
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
By choosing to accept, you acknowledge that you are a Certified Healthcare Professional.
Healthcare Professionals
Coronary Guide Catheter
The Launcher® Coronary Guide Catheter offers you a blend of flexibility, support and visualization, the capability you need to respond to your challenging cases.
Percutaneous coronary intervention (PCI), also known as coronary angioplasty, is a therapeutic procedure to treat the narrowed or stenotic section of the coronary artery of the heart due to coronary atherosclerosis. The guide catheter provides support for device advancement (stents, balloons, etc.). It is the conduit for device and wire transport, a vehicle for contrast injection and takes measurements. Guide catheters are available in a variety of shapes and sizes to fit a variety of patient anatomies.
Launcher is available in 5, 6, 7, 8F with the following inner diameter measurements:
Launcher | |
---|---|
5F | 0.058" |
6F | 0.071" |
7F | 0.081" |
8F | 0.090" |
Ordering Information
LEFT CORONARY CURVES | Backup Support Left | ||||
---|---|---|---|---|---|
Left Standard | Short Left | JCL | Amplatz Left | Short Amplatz Left | EBU |
LA5JL20 | LA5SL30 | LA5JCL15 | LA5AL75 | LA5SAL75 | LA5EBU20 |
LA5JL30 | LA5SL35 | LA5JCL30 | LA5AL10 | LA5SAL10 | LA5EBU30 |
LA5JL35 | LA5SL40 | LA5JCL35 | LA5AL15 | LA5SAL15 | LA5EBU35 |
LA5JL40 | LA5SL45 | LA5JCL40 | LA5AL20 | LA5SAL20 | LA5EBU375 |
LA5JL45 | LA5SL50 | LA5JCL45 | LA5AL25 | LA5SAL25 | LA5EBU40 |
LA5JL50 | LA5SL50 |
LA5JCL50 | LA5AL30 | LA5SAL30 | LA5EBU45 |
LA5JL60 | LA5SL60 | LA5AL40 | LA5SAL40 | LA5EBU50 | |
RIGHT CORONARY CURVES | |||||
Right Standard | Short Right | JCR | Amplatz Right | Shepherd's Crook Right | Backup Support Right |
LA5JR30 | LA5SR30 | LA5JCR35 | LA5AR10 | LA5SCR35 | LA5RBU35 |
LA5JR35 | LA5SR35 | LA5JCR40 | LA5AR20 | LA5SCR40 | LA5RBU40 |
LA5JR40 | LA5SR40 | LA5JCR45 | LA5ALR12 | LA5SCR50 | |
LA5JR45 | LA5SR50 | LA5JCR50 | ECR | ||
LA5JR50 | LA5SR60 | Short Amplatz Right | LA5ECR35 | ||
LA5JR60 | LA5SAR10 | LA5ECR40 | |||
LA5SAR20 | LA5ECR45 | ||||
3-Dimensional | |||||
LA53DRIGHT | |||||
OTHER CURVES | |||||
Multipurpose | MAC (Multi-Aortic) | Bypass | Champ | Radial Specialty | NOTO |
LA5MB1 | LA5MAC30 | LA5IMA | LA5CHAMP05 | LA5LARA | LA5NOTO |
LA5MB2 | LA5MAC35 | LA5LCB | LA5CHAMP10 | LA5MRADIAL | |
LA5MPST | LA5MAC375 | LA5RCB | LA5CHAMP15 | LA5MRESS | |
LA5HSI | LA5MAC40 | LA5RCBII | LA5CHAMP20 | LA5RRAD | |
LA5HSII | LA5MAC45 | LA5CHAMP25 | EL GAMAL | ||
LA5HSIII | LA5MAC50 | LA5CHAMP30 | LA5ELGAMAL | ||
LA5HSREL | LA5CHAMP35 | ||||
LA5CHAMP40 |
Shaft Diameter: 5F
Inner Diameter: 0.058 in.
5 packs available in select curves
LEFT CORONARY CURVES | Backup Support Left | ||||
---|---|---|---|---|---|
Left Standard (JL) | Short Left (SL) | JCL | Amplatz Left | Short Amplatz Left | EBU |
LA6JL25 | LA6SL30 | LA6JCL30 | LA6AL75 | LA6SAL75 | LA6EBU30 |
LA6JL30 | LA6SL35 | LA6JCL35 | LA6AL10 | LA6SAL10 | LA6EBU325 |
LA6JL35 | LA6SL40 | LA6JCL40 | LA6AL15 | LA6SAL15 | LA6EBU35 |
LA6JL40 | LA6SL45 | LA6JCL45 | LA6AL175 | LA6SAL20 | LA6EBU375 |
LA6JL40P^ | LA6SL50 | LA6LCL50 | LA6AL20 | LA6SAL25 | LA6EBU40 |
LA6JL45 | LA6SL60 | LA6AL25 | LA6SAL30 | LA6EBU45 | |
LA6JL50 | LA6AL30 | LA6SAL40 | LA6EBU50 | ||
LA6JL60 | LA6AL40 | ||||
LA6AL50 | |||||
Left Standard (FL) | Short Left (FLST) | ||||
LA6FL35 | LA6FL35ST | ||||
LA6FL40 | LA6FL40ST | ||||
LA6FL40G^^ | LA6FL45ST | ||||
LA6FL40P^ | LA6FL50ST | ||||
RIGHT CORONARY CURVES | |||||
Right Standard | Short Right | JCR | Amplatz Right | Shepherd's Crook Right | Backup Support Right |
LA6JR30 | LA6SR30 | LA6JCR35 | LA6AR10 | LA6SCR35 | LA6RBU35 |
LA6JR35 | LA6SR35 | LA6JCR40 | LA6AR20 | LA6SCR40 | LA6RBU40 |
LA6JR40 | LA6SR40 | LA6JCR45 | LA6ALR12 | LA6SCR50 | LA6RBU45 |
LA6JR40P^ | LA6SR45 | LA6JCR50 | |||
LA6JR45 | LA6SR50 | Short Amplatz Right | ECR | ||
LA6JR50 | LA6SR60 | LA6SAR10 | LA6ECR30 | ||
LA6JR60 | LA6SAR20 | LA6ECR35 | |||
LA6ECR40 | |||||
Right Standard (FR) | LA6ECR45 | ||||
LA6FR35 | |||||
LA6FR40 | 3-Dimensional | ||||
LA63DRC | |||||
LA63DRIGHT | |||||
OTHER CURVES | |||||
Multipurpose | MAC (Multi-Aortic) | Bypass | Champ | Peripheral | Radial Specialty |
LA6MB1 | LA6MAC30 | LA6LCB | LA6CHAMP05 | LA6CHAMP15K+ | LA6LARA |
LA6MB2 | LA6MAC35 | LA6LCBD* | LA6CHAMP10 | LA6CHAMP20K+ | LA6MRADIAL |
LA6MP1 | LA6MAC375 | LA6RCB | LA6CHAMP15 | LA6CHAMP25K+ | LA6MRESS |
LA6MP2 | LA6MAC40 | LA6RCBD* | LA6CHAMP20 | LA6IMAK+ | LA6RRAD |
LA6MPST | LA6MAC45 | LA6CBII | LA6CHAMP25 | LA6JR40K+ | |
LA6HSI | LA6MAC50 | LA6IMA | LA6CHAMP30 | LA6MP1K+ | NOTO |
LA6HSII | LA6IMAD* | LA6CHAMP35 | LA6MPHK+ | LA6NOTO | |
LA6RMSHII | LA6CHAMP40 | LA6PK1W++ | |||
LA6HSIII | LA6RDCK+ | EL GAMAL | |||
LA6ELGAMAL |
D* = 90 cm shaft length
Shaft Diameter: 6F
K+ = 55 cm shaft length
Inner Diameter: 0.071 in.
W++=47 cm shaft length
P^= Posterior
To order curves with sideholes, please add 3SH2 to end of model number
G^^= Anterior
5 packs available in select curves
LEFT CORONARY CURVES | Backup Support Left | ||||
---|---|---|---|---|---|
Left Standard (JL) | Short Left (SL) | JCL | Amplatz Left | Short Amplatz Left | EBU |
LA7JL30 | LA7SL30 | LA7JCL30 | LA7AL75 | LA7SAL75 | LA7EBU30 |
LA7JL35 | LA7SL35 | LA7JCL35 | LA7AL10 | LA7SAL10 | LA7EBU30D* |
LA7JL35G^^ | LA7SL40 | LA7JCL40 | LA7AL10D* | LA7SAL15 | LA7EBU35 |
LA7JL35P^ | LA7SL45 | LA7JCL45 | LA7AL15 | LA7SAL20 | LA7EBU35D* |
LA7JL40 | LA7SL50 | LA7JCL50 | LA7AL20 | LA7SAL25 | LA7EBU375 |
LA7JL40D* | LA7SL60 | LA7AL20D* | LA7SAL30 | LA7EBU40 | |
LA7JL40G^^ | LA7AL25 | LA7SAL40 | LA7EBU40D* | ||
LA7JL40P^ | LA7AL30 | LA7EBU45 | |||
LA7JL45 | LA7AL40 | LA7EBU50 | |||
LA7JL50 | |||||
LA7JL60 | |||||
Left Standard (FL) | |||||
LA7FL35 | |||||
LA7FL40 | |||||
LA7FL40G^^ | |||||
LA7FL40P^ | |||||
RIGHT CORONARY CURVES | |||||
Right Standard | Short Right | JCR | Amplatz Right | Shepherd's Crook Right | Backup Support Right |
LA7JR30 | LA7SR30 | LA7JCR35 | LA7AR10 | LA7SCR35 | LA7RBU35 |
LA7JR35 | LA7SR35 | LA7JCR40 | LA7AR10D* | LA7SCR40 | LA7RBU40 |
LA7JR40 | LA7SR40 | LA7JCR45 | LA7AR20 | LA7SCR50 | |
LA7JR40D* | LA7SR45 | LA7JCR50 | LA7AR20D* | ||
LA7JR40P^ | LA7SR50 | LA7ALR12 | ECR | ||
LA7JR45 | LA7SR60 | LA7ECR35 | |||
LA7JR50 | LA7ECR40 | ||||
LA7JR60 | Short Amplatz Right | LA7ECR45 | |||
LA7SAR10 | |||||
FCR | LA7SAR20 | ||||
LA7FCR35 | 3-Dimensional | ||||
LA7FCR40 | LA73DRC | ||||
LA73DRIGHT | |||||
OTHER CURVES | |||||
Multipurpose | MAC (Multi-Aortic) | Bypass | Champ | Peripheral | NOTO |
LA7HSI | LA7MAC30 | LA7IMA | LA7CHAMP05 | LA7CHAMP15K+ | LA7NOTO |
LA7HSII | LA7MAC35 | LA7IMAD* | LA7CHAMP05D* | LA7CHAMP20K+ | |
LA7RMHSII | LA7MAC375 | LA7LCB | LA7CHAMP10 | LA7CHAMP25K+ | |
LA7HSIII | LA7MAC40 | LA7LCBD* | LA7CHAMP10D* | LA7IMAK+ | El GAMAL |
LA7HSIV | LA7MAC45 | LA7RCB | LA7CHAMP15 | LA7JR40K+ | LA7ELGAMAL |
LA7MB1 | LA7MAC50 | LA7RCBD* | LA7CHAMP20 | LA7MPHK+ | |
LA7MB2 | LA7RCBII | LA7CHAMP25 | LA7MP1K+ | ||
LA7MP1 | LA7CHAMP30 | LA7MPHK+ | |||
LA7MP1D* | LA7CHAMP35 | LA7PK1W++ | |||
LA7MPST | LA7CHAMP40 | LA7RDCK+ | |||
LA7SCR40K+ | |||||
LA7STRD* |
D* = 90 cm shaft length
Shaft Diameter: 7F
K+ = 55 cm shaft length
Inner Diameter: 0.081 in.
W++=47 cm shaft length
P^= Posterior
To order curves with sideholes, please add ³SH² to end of model number
G^^= Anterior
5 packs available in select curves
LEFT CORONARY CURVES | Backup Support Left | ||||
---|---|---|---|---|---|
Left Standard (JL) | Short Left (SL) | JCL | Amplatz Left | Short Amplatz Left | EBU |
LA8JL30 | LA8SL30 | LA8JCL30 | LA8AL75 | LA8SAL75 | LA8EBU30 |
LA8JL35 | LA8SL35 | LA8JCL35 | LA8AL10 | LA8SAL10 | LA8EBU35 |
LA8JL40 | LA8SL40 | LA8JCL35D* | LA8AL10D* | LA8SAL15 | LA8EBU35D* |
LA8JL40D* | LA8SL45 | LA8JCL40 | LA8AL15 | LA8SAL20 | LA8EBU375 |
LA8JL45 | LA8SL50 | LA8JCL40D* | LA8AL20 | LA8SAL25 | LA8EBU40 |
LA8JL50 | LA8SL60 | LA8JCL45 | LA8AL20D* | LA8SAL30 | LA8EBU40D* |
LA8JL60 | LA8JCL45D* | LA8AL25 | LA8SAL40 | LA8EBU45 | |
LA8JL70 | LA8JCL50 | LA8AL30 | LA8EBU50 | ||
LA8JL80 | LA8AL40 | ||||
LA8AL40D* | |||||
LA8AL50 | |||||
RIGHT CORONARY CURVES | |||||
Right Standard | Short Right | JCR | Amplatz Right | Shepherd's Crook Right | Backup Support Right |
LA8JR30 | LA8SR30 | LA8JCR35 | LA8AR10 | LA8SCR35 | LA8RBU35 |
LA8JR35 | LA8SR35 | LA8JCR40 | LA8AR20 | LA8SCR40 | LA8RBU40 |
LA8JR35D | LA8SR40 | LA8JCR45 | LA8ALR12 | LA8SCR50 | LA8RBU40D |
LA8JR40 | LA8SR45 | LA8JCR50 | |||
LA8JR40D | LA8SR50 | ECR | |||
LA8JR45 | LA8SR60 | LA8ECR35 | |||
LA8JR50 | LA8ECR40 | ||||
LA8JR60 | Short Amplatz Right | LA8ECR45 | |||
LA8SAR10 | |||||
LA8SAR20 | |||||
3-Dimensional | |||||
LA83DRC | |||||
OTHER CURVES | |||||
Multipurpose | MAC (Multi-Aortic) | Bypass | Champ | Peripheral | NOTO |
LA8HSI | LA8MAC30 | LA8IMA | LA8CHAMP05 | LA8CARL3D* | LA8NOTO |
LA8HSII | LA8MAC35 | LA8IMAD* | LA8CHAMP10 | LA8CARLD* | |
LA8RMHSII | LA8MAC375 | LA8LCB | LA8CHAMP15 | LA8CHAMP15K+ | |
LA8HSIII | LA8MAC40 | LA8LCBD* | LA8CHAMP20 | LA8CHAMP20K+ | |
LA8MB1 | LA8MAC45 | LA8RCB | LA8CHAMP25 | LA8CHAMP25K+ | |
LA8MB1D* | LA8MAC50 | LA8RCBD* | LA8CHAMP30 | LA8IMAK+ | |
LA8MB2 | LA8RCBII | LA8CHAMP35 | LA8JR40K+ | ||
LA8MB2D* | LA8CHAMP40 | LA8MP1K+ | EL GAMAL | ||
LA8MP1 | LA8MPHK+ | LA8ELGAMAL | |||
LA8MPST | LA8PK1W++ | LA8ELGAMAL2 | |||
LA8RDCK+ | LA8ELGAMAL3 | ||||
LA8SCR40K+ | |||||
LA8STRD* | |||||
LA8STRK+ | |||||
LA8SW1 | |||||
LA8SW1D* |
D* = 90 cm shaft length
Shaft Diameter: 8F
K+ = 55 cm shaft length
Inner Diameter: 0.090 in.
W++=47 cm shaft length
P^= Posterior
To order curves with sideholes, please add 3SH2 to end of model number
G^^= Anterior
5 packs available in select curves
IMPORTANT INFORMATION ON INDICATIONS, SAFETY AND WARNINGS
For listing of Indications, Contraindications, Warnings, Precautions, and Potential Adverse Events, please refer to the Instructions For Use .