placeen-us

EEA™ Circular Stapler with Tri-Staple™ Technology

Product Details

Staple line security times three.

EEA™ circular stapling now comes with our clinically proven Tri-Staple™ technology.

That means you can have the confidence and security([FOOTNOTE=Based on internal test report #2128-194, Comparison of EEA™ circular stapler with Tri-Staple™ technology to EEA™ circular stapler with DST Series™ technology in colocolonic and gastrojejunal anastomoses. Aug. 20, 2015.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #RE0036707, Pilot: comparison of EEA™ circular stapler with Tri-Staple™ technology to EEA™ circular stapler with DST Series™ technology in an esophago-gastrostomy using a canine model. Feb. 25, 2015.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #2128-097, Evaluation of early wound healing events in gastrojejunostomies and colonic anastomosis using a three row EEA™ stapler in canines. Aug. 7, 2013.],[ANCHOR=],[LINK=]),†,‡ of three rows of varied height staples([FOOTNOTE=Based on internal test report #RE00069039, EEA™ circular stapler with Tri-Staple™ technology design verification report. Dec. 2, 2014.],[ANCHOR=],[LINK=]) while your patients benefit from:

  • Less stress on tissue during compression and clamping([FOOTNOTE=Based on internal test report #PCG-30, Comparison of circular staplers: tissue compression profiles as determine by 2-D static axisymmetric finite element analysis (FEA).],[ANCHOR=],[LINK=]),†,Ω
  • The potential for greater perfusion at the staple line([FOOTNOTE=Based on internal test report #PCG-007, Media absorbency under clamped conditions. Aug. 6, 2012.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #2128-002-2, Extrapolation of perfusion studies performed for Endo GIA™ with Tri-Staple™ technology: final analysis of staple line vascularity using MicroCT. April 27, 2015.],[ANCHOR=],[LINK=]),‡,§

EEA™ Circular Stapler with DST Series™ Technology

Product Details

The EEA™ circular stapler with DST Series™ technology embodies our commitment to innovation and collaboration with the surgical community. Our circular staplers incorporate more than three decades of experience and input from leading bariatric, colorectal, and general surgeons throughout the world.

DST Series™ EEA™ staplers incorporate proprietary directional stapling technology (DST), 3.5 mm staples, and a host of other unique features.

View Order Information

Order Information
EEA™ Circular Stapler with DST Series™ Technology
order Code Lumen size Color Code Staple Height Tissue Type unit of measure quantity
EEA2135 21 mm Aqua 3.5 mm Medium Each 1
EEA21 21 mm Aqua 4.8 mm Thick Each 1
EEAXL2135 21 mm Aqua 3.5 mm Medium Each 1
EEAXL21 21 mm Aqua 4.8 mm Thick Each 1
EEA2535 25 mm White 3.5 mm Medium Each 1
EEA25 25 mm White 4.8 mm Thick Each 1
EEAXL2535 25 mm White 3.5 mm Medium Each 1
EEAXL25 25 mm White 4.8 mm Thick Each 1
EEA2835 28 mm Blue 3.5 mm Medium Each 1
EEA28 28 mm Blue 4.8 mm Thick Each 1
EEAXL2835 28 mm Blue 3.5 mm Medium Each 1
EEAXL28 28 mm Blue 4.8 mm Thick Each 1
EEA31 31 mm Green 4.8 mm Thick Each 1
EEAXL31 31 mm Green 4.8 mm Thick Each 1
EEA33 33 mm Yellow 4.8 mm Thick Each 1
EEAXL33 33 mm Yellow 4.8 mm Thick Each 1

DST Series™ EEA™ OrVil™ Device

Product Details

The DST Series™ EEA™ OrVil™ 21 mm device is a DST Series™ EEA™ 21 mm anvil assembly, and the DST Series™ EEA™ OrVil™ 25 mm device is a DST Series™ EEA™ 25 mm anvil assembly, both with the anvil head secured in the tilted position. The anvil assembly is mounted on a 90 cm long PVC delivery tube and is secured to the tube with a suture.

Only for use with the DST Series™ EEA™ XL 21 or 25 mm stapler.

EEA™ Hemorrhoid and Prolapse Stapler Set with DST Series™ Technology

Product Details

The EEA™ hemorrhoid and prolapse stapler set with DST Series™ technology is designed for use as a stapler instrument for control of rectal prolapse and hemorrhoid disease. The instrument places a circular, double-staggered row of titanium DST™ staples and removes a circular tissue specimen. It is offered in a 33 mm diameter size with either 3.5 mm or 4.8 mm staples.

The accompanying accessories include an access port, anoscope, and dilator.

View Order Information

Order Information
EEA™ Hemorrhoid and Prolapse Stapler Set with DST Series™ Technology
order Code Lumen Size Color Code Staple Height Tissue Type Unit of Measure Quantity
HEM3335 33 mm Blue 3.5 mm Medium Each 1
HEM3348 33 mm Green 4.8 mm Thick Each 1

Premium Plus CEEA™ Staplers

Product Details

Premium Plus CEEA™ staplers place a circular, double staggered row of titanium staples. The instrument is activated by squeezing the handles firmly as far as they will go. Immediately after staple formation, the knife blade resects the excess tissue, creating a circular anastomosis.

The diameter of the staple line is determined by the selection of the 34 mm, 31 mm, 28 mm, 25 mm, or 21 mm stapler. The Tilt-Top™ anvil is available on the 34, 31, 28 and the 25 mm staplers.