placeEurope

Overview

44% fewer leaks1,†,††  

EEA™ circular stapling now comes with our clinically proven Tri-Staple™ technology. 

That means you can have consistent performance in circular stapling — over a broad range of tissue.3,4,5,†,§ You and your patients can benefit from:

  • Greater leak protection vs. the Ethicon™* CDH1,†,‡
  • Less stress on tissue during compression and clamping6,†,‡‡,§§
  • Greater perfusion allowed into the staple line2,§,Ω
Order Information
Order Code Description Color Staple Size
(Inner to Outer Row)
Unit of
Measure
Quantity
TRIEEA28MT EEA™ Circular Staple with Tri-Staple™ Technolog 28 mm Medium/Thick Purple 3.0 mm, 3.5 mm, 4.0 mm Box 3
TRIEEA28XT EEA™ Black Circular Staple with Tri-Staple™ Technolog 28 mm Extra Thick Black 4.0 mm, 4.5 mm, 5.0 mm Box 3
TRIEEAXL28MT  EEA™ Circular Stapler with Tri-Staple™ Technology 28 mm Medium/Thick XL Purple 3.0 mm, 3.5 mm, 4.0 mm Box 3
TRIEEAXL28XT EEA™ Black Circular Stapler with Tri-Staple™ Technology28 mm Extra Thick XL Black 4.0 mm, 4.5 mm, 5.0 mm Box 3
TRIEEA31MT EEA™ Circular Stapler with Tri-Staple™ Technology 31 mm Medium/Thick Purple 3.0 mm, 3.5 mm, 4.0 mm Box 3
TRIEEA31XT EEA™ Black Circular Stapler with Tri-Staple™ Technology 31 mm Extra Thick Black 4.0 mm, 4.5 mm, 5.0 mm Box 3
TRIEEAXL31MT EEA™ Circular Stapler with Tri-Staple™ Technology 31 mm Medium/Thick XL Purple 3.0 mm, 3.5 mm, 4.0 mm Box 3
TRIEEAXL31XT EEA™ Black Circular Stapler with Tri-Staple™ Technology 31 mm Extra Thick XL Black 4.0 mm, 4.5 mm, 5.0 mm Box 3

Order Information

Made For Today’s Procedures

Introduce next-gen circular stapling to your OR

Our EEA™ circular stapler with Tri-Staple™ technology was designed to support anastomosis with:

  • A sloped cartridge face that puts less stress on tissue during compression and clamping6,†,Ω
  • Improved audible feedback7,†,‡‡
  • A Tilt-top™ anvil to facilitate removal
  • 30% more staples than staplers with the same lumen diameters8

We developed features like those because procedures — and tissue thicknesses — vary.

The Extra Row Matters

See how Tri-Staple™ technology stacks up to two-row circular staplers

Our EEA™ circular stapler delivers three-rows of varied height staples for consistency across a broad range of tissue thicknesses.3,4,5,†,§ Together with a sloped cartridge face3,†, it provides less stress on tissue6,†,‡‡ compared to Ethicon™* CDH and DST Series™ technology.

Tri-Staple™ technology also delivers:

  • 44% fewer leaks vs. Ethicon™* CDH1,†,††
  • Greater perfusion allowed into the staple line2,§,Ω
  • 62% reduction in firing force vs. the Ethicon™* CDH circular staplers9,†
  • The same inner/outer lumen diameters as DST Series™ technology3,†
Side-by-side purple and black lumen comparison
  • †Preclinical results may not correlate with clinical performance in humans.
  • ‡Based on the addition of a third row of staples in the EEA™ circular stapler with Tri-Staple™ technology, as compared to predicate two row device designs.
  • §Compared to two-row staplers.
  • ΩFinite element analysis (FEA) was used to determine the strain profiles of three circular staplers during clamp-up. The EEA™ circular stapler with Tri-Staple™ technology demonstrated a graduated compression profile upon clamping.
  • ††Refers to the healing period (generally through day 28) that was evaluated in multiple preclinical (canine) survival studies designed to assess device safety and efficacy.
  • ‡‡16 out of 19 surgeons surveyed agreed.
  • 1. Based on internal report #RE00318260, Comparative leak testing for EEA™ circular stapler with Tri-Staple™ technology and Ethicon™* CDH. April 2021.
  • 2. Based on internal test report #RE00265643, EEA™ circular stapler with Tri-Staple™ technology perfusion study. July 2020.
  • 3. Based on internal test report #RE00069039, EEA™ circular stapler with Tri-Staple™ technology design verification report. Dec. 2, 2014.
  • 4. Based on internal test report #RE00008030, Tulip benchmark test report. March 18, 2016.
  • 5. Based on internal test report #2128-053, Ethicon™* benchmark testing ― Signia™ circular reload. June 17, 2014.
  • 6. Based on internal test report #RE00200393 rev 2, Comparison of circular staplers: tissue compression profiles as determined by 2-D static axisymmetric finite element analysis (FEA). June 17, 2021.
  • 7. Based on internal test report #RE00073061, Tulip formative evaluation summary.
  • 8. Zhang J. The use of the language “EEA™ circular stapler with Tri-Staple™ technology has 30 percent more staples in the staplers of the same lumen diameters as compared to two row circular staplers” in marketing materials [memorandum]. North Haven, CT: Medtronic.
  • 9. Based on internal test report #RE00183973_B, Firing force and audible feedback test report. July 2020.